Plan Review Details - Permit 21080480
Plan Review Stops For Permit 21080480
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-12-09 Cont ID  
Sent By cthroop Date 2021-12-09 Time 15:07 Rev Time 0.00
Received By cthroop Date 2021-12-09 Time 15:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-12-03 Cont ID  
Sent By cthroop Date 2021-12-03 Time 16:05 Rev Time 0.00
Received By cthroop Date 2021-12-02 Time 15:51 Sent To  
Notes
2021-12-03 16:13:43BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1. PROVIDE PRODUCT APPROVALS FOR NEW EXT. DOOR, OHD AND
 SGD. (OHD REMOVED FROM SOW. PROVIDE COVER SHEET FOR
 FL15180.1. 2ND REQUEST- PROVIDE PRODUCT APPROVAL FOR
 SGD)
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 NOTICE: SGD DOES NOT HAVE TO BE IMPACT RATED. INTERIOR
 INSTALLATION ONLY.
 THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE
 VERSION, AND STATUS, FBC R 301.
  
  
 2. (CHANGE IN SOW, SITE PLAN NOT REQUIRED)
  
  
 3. (CHANGE IN SOW, DETAIL NOT REQUIRED)
  
 NEW COMMENT:
  
 BASED ON THE CHANGE IN THE SOW, REMOVE STRUCTURAL PLANS
 S-1, S-2 AND S-3.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-13 Cont ID  
Sent By cthroop Date 2021-11-13 Time 10:31 Rev Time 0.00
Received By cthroop Date 2021-11-13 Time 09:48 Sent To  
Notes
2021-11-13 10:46:34BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PRODUCT APPROVALS FOR NEW EXT. DOOR, OHD AND
 SGD.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 NOTICE: SGD DOES NOT HAVE TO BE IMPACT RATED. INTERIOR
 INSTALLATION ONLY.
  
 DEFERRAL OPTION:
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 2. PROVIDE A SITE PLAN WITH BOUNDRY LINE SURVEY.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
  
 3. PROVIDE DETAIL FOR NEW SLAB TO EXISTING SLAB.
 TYPICAL DETAIL WOULD INCLUDE #5 REBAR EPOXY EMBEDDED 6
 INCHES INTO EXISTING SLAB. SPACING WOULD TYPICALLY BE
 6" FROM END, 24" O.C.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-03 Cont ID  
Sent By cthroop Date 2021-12-03 Time 13:59 Rev Time 0.00
Received By cthroop Date 2021-12-03 Time 10:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-11-08 Cont ID  
Sent By jleahy Date 2021-11-08 Time 10:03 Rev Time 0.00
Received By jleahy Date 2021-11-08 Time 09:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-09 Cont ID  
Sent By lmarchan Date 2021-12-09 Time 10:54 Rev Time 0.00
Received By lmarchan Date 2021-11-22 Time 11:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-13 Cont ID  
Sent By cthroop Date 2021-11-13 Time 10:46 Rev Time 0.00
Received By cthroop Date 2021-10-14 Time 08:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-11-23 Cont ID  
Sent By medwards Date 2021-11-23 Time 07:39 Rev Time 0.00
Received By medwards Date 2021-11-23 Time 07:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-10-15 Cont ID  
Sent By   Date 2021-10-15 Time   Rev Time 0.00
Received By   Date 2021-10-15 Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-03 Cont ID  
Sent By lcrespo Date 2021-12-03 Time 09:39 Rev Time 0.00
Received By lcrespo Date 2021-11-29 Time 11:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-11-29 Cont ID  
Sent By abelisle Date 2021-10-20 Time 06:46 Rev Time 0.00
Received By lcrespo Date 2021-10-20 Time 06:22 Sent To  
Notes
2021-10-20 06:46:481ST REVIEW FBC-2020 PLUMBING
 PERMIT-21080480
 10/20/2021
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020
 FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH
 EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH
 EDITION 2020
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) INDICATE ON THE PLAN WHERE THE WATER HEATER AND THE
 CLOTHES WASHING MACHINE ARE GOING TO BE LOCATED. WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS
 2) SIGNED AND SEALED DRAWINGS AND DOCUMENTS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 BY THE ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC
 PLAN REVIEW. - OR - IF YOUR ENGINEER OR ARCHITECT DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - PLEASE
 DROP OFF (CITY HALL DROP BOX) THE ORIGINAL SIGNED AND
 SEALED DRAWINGS/DOCUMENTS ALONG WITH A "PLAN REVIEW
 REQUEST FORM" EXPLAINING THE REASON FOR SUBMITTING THE
 DOCUMENT OR DRAWINGS. PLAN REVIEW REQUEST FORM CAN BE
 OBTAINED BY E MAILING [email protected] AND ASKING FOR THE
 FORM.
 3) A PORTION OF SHEET A-2 DETAIL # 1 IS ILLEGIBLE.
 SUBMIT A CLEAR AND LEGIBLE DETAIL FOR REVIEW. WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
 4) PLEASE PROVIDE A WATER ISOMETRIC DRAWING. PER WPB
 AMEND TO FBC 107.3.5.1.3(13)
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 ATELYO BELISLE
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2021-11-13 Cont ID  
Sent By cthroop Date 2021-11-13 Time 10:24 Rev Time 0.00
Received By cthroop Date 2021-11-13 Time 10:22 Sent To  
Notes
2021-11-13 10:25:03SEE PROVISO ON PLAN PAGE S-1: A SEPERATE ROOFING PERMIT
 IS REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-12-03 Cont ID  
Sent By cthroop Date 2021-12-03 Time 16:05 Rev Time 0.00
Received By cthroop Date 2021-12-02 Time 15:51 Sent To  
Notes
2021-12-03 16:05:25NO STRUCTURAL DESIGN. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-11-13 Cont ID  
Sent By cthroop Date 2021-11-13 Time 10:30 Rev Time 0.00
Received By cthroop Date 2021-11-13 Time 09:48 Sent To  
Notes
2021-11-13 10:31:10SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-12-09 Cont ID  
Sent By llouie Date 2021-12-09 Time   Rev Time 0.00
Received By llouie Date 2021-12-09 Time   Sent To  
Notes
2021-12-09 09:44:43* INTERIOR REMODEL ONLY.

Review Stop Z ZONING
Rev No 1 Status F Date 2021-10-22 Cont ID  
Sent By llouie Date 2021-10-22 Time   Rev Time  
Received By llouie Date 2021-10-22 Time   Sent To  
Notes
2021-10-22 11:06:08** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY IS
 REQUIRED.
  
 2.) PLEASE NOTE THAT THE AREA OF THE EXISTING AREA
 CONSIDERED IN THE SCOPE OF WORK MUST BE SETBACK AT
 LEAST 25 FT. FROM THE FRONT PROPERTY LINE TO MEET THE
 MINIMUM REQUIRED FRONT SETBACK OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDRS); ANY EXISTING
 NON-CONFORMING STRUCTURE MAY NOT BE ENCLOSED. [ZLDR
 S.94-72]
  
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  
 * DOES NOT EXCEED 50% THRESHOLD FOR LANDSCAPE
 IMPROVEMENTS.
  