Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-09-28 Cont ID  
Sent By pvalenti Date 2021-09-28 Time 14:20 Rev Time 0.00
Received By pvalenti Date 2021-09-28 Time 14:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-02 Cont ID  
Sent By pvalenti Date 2021-09-02 Time 16:27 Rev Time 0.00
Received By pvalenti Date 2021-09-02 Time 15:59 Sent To  
Notes
2021-09-02 16:32:09****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, THE OPENING SCHEDULE FASTENER SPACING IS
 DIFFERENT THAN WHAT IS INDICATED IN THE PRODUCT
 APPROVAL. FOR 12" ON CENTER SPACING THE PRODUCT
 APPROVAL INDICATES A WOOD SUBSTRATE. FOR A CONCRETE
 SUBSTRATE THE PRODUCT APPROVAL INDICATES A FASTENER
 SPACING OF 7.5" ON CENTER. PLEASE RE-EVALUATE AND
 RE-SUBMIT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-28 Cont ID  
Sent By pvalenti Date 2021-09-28 Time 14:21 Rev Time 0.00
Received By pvalenti Date 2021-09-07 Time 16:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-02 Cont ID  
Sent By pvalenti Date 2021-09-02 Time 16:32 Rev Time 0.00
Received By pvalenti Date 2021-08-11 Time 11:56 Sent To  
Notes
***NONE***