Plan Review Details - Permit 21080468
| Plan Review Stops For Permit 21080468 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-23 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-23 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-23 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-23 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2021-08-23 12:26:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PREVIOUS COMMENTS WERE ADDRESSED, BUT A NEW PRODUCT | | | APPROVAL WAS SUBMITTED (POLYGLASS MODIFIED FOR FLAT | | | DECKS). IF THIS ROOF HAS A FLAT DECK THAT WILL BE | | | INCLUDED IN THE SCOPE, INDICATE WHICH APPROVED ASSEMBLY | | | IS PROPOSED. IF REQUIRED PROVIDE CALCULATIONS FOR ZONES | | | 2 & 3. | | | | | | FBC R 301 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-08-12 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-08-12 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2021-08-12 08:17:32 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL27499-R3 HAS BEEN | | | REVISED TO FL27499-R4. PLEASE PROVIDE A COMPLETE SET. | | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. | | | 2. SUBMITTED PRODUCT APPROVAL FL5259-R31 HAS BEEN | | | REVISED TO FL5259-R33. PLEASE PROVIDE A COMPLETE SET. | | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. | | | 3. FBC B 107.2.1 REVISE VALUATION ON PERMIT APPLICATION | | | TO MATCH CONTRACT VALUATION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-23 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-23 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-08-12 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-08-11 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
|