| 2022-04-04 10:38:13 | RE-ROOF SECOND BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21080306 |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | ORIGINAL COMMENT: |
| | 1- GAF SINGLE PLY ROOFING SYSTEM NOA 18-0523.05 |
| | SUBMITTED: |
| | A) OK. |
| | |
| | B) MECHANICAL ATTACHMENT ASSEMBLIES REQUIRE A SIGNED |
| | AND SEALED FIELD WITHDRAWAL RESISTANCE TESTING IN |
| | COMPLIANCE WITH TESTING APPLICATION STANDARD TAS 105 AS |
| | REQUIRED BY STEEL DECK SYSTEM LIMITATIONS ON LAST PAGE |
| | OF NOA SUBMITTED. |
| | |
| | RESPONSE: |
| | FLORIDA PRODUCT APPROVAL SUBMITTED FL16730-R35 ALSO |
| | REQUIRES WITHDRAWAL RESISTANCE TESTING IN COMPLIANCE |
| | WITH TESTING APPLICATION STANDARD TAS 105. SEE |
| | LIMITATION 5.6.1. PROVIDE SIGNED AND SEALED TEST |
| | REPORT. |
| | |
| | 2- ENGINEER TO REVISE THE INSULATION FASTENING |
| | SPECIFICATIONS TO MATCH INSULATION ATTACHMENT REQUIRED |
| | BY SELECTED ASSEMBLY S-372 ON PAGE 66 OF 122. |
| | NOTE: REVISE ROOF DIAGRAM AND INSULATION ATTACHMENT |
| | DETAIL AS REQUIRED TO MATCH ABOVE. |
| | |
| | 3-FLORIDA PRODUCT APPROVAL FL16730-R35 SUBMITTED IS |
| | INCOMPLETE. NEED TO PROVIDE COMPLETE FLORIDA PRODUCT |
| | APPROVAL, INCLUDING THE FLORIDA PRODUCT APPROVAL COVER |
| | PAGE. THE FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE |
| | IT SHOWS IF PRODUCT IS APPROVED AND CURRENT CODE IN |
| | EFFECT. CHAPTER 553 F.S. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |