Plan Review Details - Permit 21080147
Plan Review Stops For Permit 21080147
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-08-21 Cont ID  
Sent By shill Date 2021-08-21 Time 07:09 Rev Time 0.00
Received By shill Date 2021-08-21 Time 07:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-08-27 Cont ID  
Sent By jleahy Date 2021-08-27 Time 15:09 Rev Time 0.00
Received By jleahy Date 2021-08-26 Time 09:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-08-09 Cont ID  
Sent By pleduc Date 2021-08-09 Time   Rev Time 0.00
Received By pleduc Date 2021-08-09 Time 09:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-14 Cont ID  
Sent By pvalenti Date 2021-09-14 Time 16:16 Rev Time 0.00
Received By pvalenti Date 2021-09-02 Time 15:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-27 Cont ID  
Sent By jleahy Date 2021-08-27 Time 15:09 Rev Time 0.00
Received By jleahy Date 2021-08-05 Time 10:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-08-21 Cont ID  
Sent By medwards Date 2021-08-21 Time 09:54 Rev Time 0.00
Received By medwards Date 2021-08-21 Time 09:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-14 Cont ID  
Sent By pvalenti Date 2021-09-14 Time 16:12 Rev Time 0.00
Received By pvalenti Date 2021-09-14 Time 09:33 Sent To  
Notes
2021-09-14 16:12:5521080147 1411 N FLAGLER DR # 6700
  
  
 PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
  
 PROVISO: PER WPB FBC 107.2.1, PROVIDE REVISED DRAWINGS
 AS FOLLOW:
  
 1. P1.1 SHALL BE REVISED TO SHOW THE PATIENT TOILET
 ROOM CONFIGURATION TO BE THE SAME AS THAT SHOWN ON
 A1.0.
  
 2. P1.1 SHALL BE REVISED TO ELIMINATE NOTE FOR SANITARY
 TO RUN IN WET WALL.
  
 3. P2.1 SANITARY RISER DIAGRAM SHALL SHOW THE WATER
 CLOSET FIXTURE DRAIN CONTINUING UNDER THE FLOOR AND
 TURN UP IN THE WALL BEHIND THE WATER CLOSET. SEE
 MANUFACTURER?S INSTALLATION MANUAL.
  
 4. REVISED DRAWINGS SHALL BE SUBMITTED, APPROVED AND ON
 SITE PRIOR TO FIRST INSPECTION. PROCEED AT YOUR OWN
 RISK.
  
  
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21080147 1411 N FLAGLER DR # 6700
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-08-26 Cont ID  
Sent By jesmith Date 2021-08-26 Time 09:23 Rev Time 0.00
Received By pvalenti Date 2021-08-17 Time 17:02 Sent To  
Notes
2021-08-26 09:23:59CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21080147 1411 N FLAGLER DR # 6700
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 1.THE REVISED PLUMBING RISER AND PLAN VIEW INDICATE A
 REAR OUTLET WATER CLOSET WILL BE REQUIRED FOR THE
 PATIENT TOILET ROOM. PER WPB FBC 107.2.1, SPECIFY,
 PROVIDE DESIGNATION, REVISE FIXTURE SCHEDULE ON P0.1
 AND SUBMIT.
  
 2.PER WPB FBC 107.2.1, PROVIDE MANUFACTURER
 SPECIFICATION/INSTALLATION MANUAL(S) FOR THE KEMPER
 BALANCING VALVE AND KHS FLOW SPLITTERS.
  
 3. PER WPB FBC 107.2.1, INDICATE THE KEMPER BALANCING
 VALVE ON WATER HEATER DETAIL ON P0.1.
  
 4.IT IS ALSO NOTED AT THIS TIME THAT THE EXPANSION TANK
 IN THE WATER HEATER DETAIL ON P0.1 IS LOCATED UPSTREAM
 OF THE CHECK VALVE. FBC PL 607.3, PLACE EXPANSION TANK
 BETWEEN THE CHECK VALVE AND THE WATER HEATER.
  
 5.REVISED FLOOR PLAN P1.1 FOR PATIENT TOILET ROOM DOES
 NOT MATCH BATHROOM FIXTURE CONFIGURATION ON A-1.0. PER
 FBC 107.2.1, CLARIFY AND RECONCILE.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21080147 1411 N FLAGLER DR # 6700

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-09-14 Cont ID  
Sent By pvalenti Date 2021-09-14 Time 16:16 Rev Time 0.00
Received By pvalenti Date 2021-09-14 Time 16:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-21 Cont ID  
Sent By medwards Date 2021-08-21 Time 09:55 Rev Time 0.00
Received By medwards Date 2021-08-21 Time 09:55 Sent To  
Notes
***NONE***