| Plan Review Stops For Permit 21080119 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-16 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-15 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-01 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-29 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-30 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-29 |
Time |
06:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-30 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-26 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-16 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-16 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-01 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-01 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2021-11-01 08:10:38 | PLEASE RESPOND TO NOTE 2 FROM PREVIOUS REVIEW BELOW: | | | | | | 2) THE RESPONSE LETTER DATED AUG. 30, 2021 STATES THAT | | | THE OUTDOOR AIR FOR THE LOBBY AND CORRIDOR 2 IS BEING | | | SUPPLIED BY NATURAL VENTILATION. AS I LOOK AT THE | | | SUBMITTED DRAWING I SEE DOORS ENCLOSING THESE AREAS. | | | PLEASE PROVIDE DETAIL DRAWINGS SHOWING HOW THESE AREAS | | | ARE TO BE NATURALLY VENTILATED. PLEASE REMEMBER IF | | | THERE ARE DOORS IN THE OPENINGS YOU CAN NOT USE THE | | | NATURAL VENTILATION METHOD OF FBC M 402. PLEASE ALSO | | | REMEMBER THAT ADJOINING SPACES WOULD BE REQUIRED TO | | | MEET THE 8 PERCENT OF THE FLOOR AREA IN FBC M 402.3 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-30 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-30 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2021-09-30 08:42:30 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21080119 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS AND THE | | | ENERGY CALCULATIONS ARE NOT IN THE UPLOADED FILES FOR | | | THIS PROJECT. PLEASE SUBMIT THEM SO I CAN REVIEW THE | | | DOCUMENTS. FBC 107.2.1 | | | | | | 2) THE RESPONSE LETTER DATED AUG. 30, 2021 STATES THAT | | | THE OUTDOOR AIR FOR THE LOBBY AND CORRIDOR 2 IS BEING | | | SUPPLIED BY NATURAL VENTILATION. AS I LOOK AT THE | | | SUBMITTED DRAWING I SEE DOORS ENCLOSING THESE AREAS. | | | PLEASE PROVIDE DETAIL DRAWINGS SHOWING HOW THESE AREAS | | | ARE TO BE NATURALLY VENTILATED. PLEASE REMEMBER IF | | | THERE ARE DOORS IN THE OPENINGS YOU CAN NOT USE THE | | | NATURAL VENTILATION METHOD OF FBC M 402. PLEASE ALSO | | | REMEMBER THAT ADJOINING SPACES WOULD BE REQUIRED TO | | | MEET THE 8 PERCENT OF THE FLOOR AREA IN FBC M 402.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-30 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-30 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2021-08-30 09:36:33 | FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC C403.2.1 | | | | | | 2) PLEASE SHOW THE OUTDOOR AIR CALCULATIONS FOR THE | | | CORRIDORS AND SHOW HOW THE OUTDOOR AIR WILL BE SUPPLIED | | | TO THE CORRIDORS. FBC M TABLE 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-16 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-16 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-01 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-01 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2021-11-01 08:26:29 | SHEET M2.1 IS MISSING THE THIRD PARTY CERTIFIED DIGITAL | | | SIGNATURE. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-30 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-30 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-30 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-30 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2021-08-30 09:40:01 | THE DRAWINGS WERE SUBMITTED DIGITALLY BUT THE ENGINEERS | | | STAMP AND SIGNATURE APPEAR TO BE A COPY OF THE | | | ORIGINAL. PLEASE PROVIDE DIGITALLY SIGNED ORIGINAL | | | DRAWINGS. YOU MAY ALSO BRING TO OUR OFFICE THE ORIGINAL | | | SIGNED AND SEALED PAPER DRAWINGS. F.S. 471 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|