Plan Review Details - Permit 21080065
| Plan Review Stops For Permit 21080065 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-03 |
Time |
06:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-02 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2021-09-03 06:54:58 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/RPX306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | REF. OPENING #5 ON SHUTTER SCHEDULE AND FL31658-R2 FOR | | | THE FOLLOWING COMMENTS: | | | | | | 1. PER PRODUCT APPROVAL, NOTE #6. THIS IS A MOTOR | | | DRIVEN ROLL-UP SHUTTER. AN ELECTRICAL PERMIT IS | | | REQUIRED. SEE COMMENTS UNDER ELECTRICAL REVIEW. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVAL FOR ROLL-UP MECHANISM AND | | | HOOD ASSEMBLY. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3. PER PRODUCT APPROVAL, PAGE 7, FASTENER SCHEDULE, | | | FASTENERS SHALL BE 1/4" ALL-POINTS SOLID SET. | | | | | | REF. OPENINGS 1 THRU 4 AND 6 THRU 10 ON SHUTTER | | | SCHEDULE AND FL1850-R13 FOR THE FOLLOWING COMMENT: | | | | | | 4. SEE PRODUCT APPROVAL, PAGE 12, FASTENER SCHEDULE, | | | FASTENERS SHALL BE TAPCONS W/ADVANCED THREAD FORM | | | TECHNOLOGY. | | | | | | REF. SHUTTER SCHEDULE FOR THE FOLLOWING COMMENT: | | | | | | 5. TYPE OF ANCHOR SPECIFIED. WHEN MORE THAN ONE TYPE OF | | | DEVICE IS INSTALLED, INCLUDE ALL TYPES OF ANCHORS USED. | | | ANCHORS SHALL BE SPECIFIC PER NOTE #1 ON SHUTTER | | | SCHEDULE. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-02 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-02 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2021-09-02 18:52:38 | ELECTRICAL PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/RPX306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTE: FLOOR PLAN INDICATES OPENING #5 WILL BE A MOTOR | | | DRIVEN ROLL UP SHUTTER. | | | | | | 1. PROVIDE AN ELECTRICAL PERMIT. | | | 105.1 REQUIRED. | | | | | | 2. PROVIDE AN ELECTRICAL DISCONNECT FOR THE MOTOR | | | CONNECTION. | | | E4101.5 DISCONNECTING MEANS. | | | | | | 3. PROVIDE AN UPDATED PANEL SCHEDULE. IDENTIFY MOTOR | | | CIRCUT. | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-03 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-11 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-03 |
Time |
05:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-02 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2021-09-03 06:05:09 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/RPX306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | REF. DESIGN WIND LOADS PER ASCE 7-16 | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT. SEE NOTICE | | | BELOW: | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | NOTICE: | | | | | | FOR RESIDENTIAL PROPERTIES, DESIGN WIND LOADS ARE NOT | | | REQUIRED TO BE PREPARED BY A DESIGN PROFESSIONAL. THE | | | CONTRACTOR MAY PROVIDE DESIGN WIND LOADS. REFERENCE FBC | | | R CHPT. 3. | | | | | | YOU MAY RE-SUBMIT THE DESIGN WIND LOADS WITH A VALID | | | DIGITAL SIGNATURE OF A DESIGN PROFESSIONAL, SUBMIT | | | DESIGN WIND LOADS PREPARED BY THE CONTRACTOR OR TAKE NO | | | ACTION. | | | IF NO ACTION TAKEN, I AM REQUIRED TO LOCK THEM FROM | | | PRINTING DUE TO AN INVALID SIGNATURE OF THE DESIGN | | | PROFESSIONAL BUT WILL NOT FAIL YOUR 2ND REVIEW BASED ON | | | THIS. | | | | | | I CAN VERIFY THE SITE DESIGN WIND LOADS PER FBC R CHPT. | | | 3 BUT A PREPARDD DESIGN WIND LOAD CHART EXPEDITES THE | | | REVIEW PROCESS. | | | |
|
|
|