Plan Review Details - Permit 21071631
Plan Review Stops For Permit 21071631
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-11-03 Cont ID  
Sent By jgomez Date 2021-11-03 Time 12:42 Rev Time 0.00
Received By jgomez Date 2021-11-03 Time 10:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By jgomez Date 2021-10-26 Time 17:05 Rev Time 0.00
Received By jgomez Date 2021-10-26 Time 16:28 Sent To  
Notes
2021-10-26 17:06:46BUILDING APPROVED WITH PROVISO:
 1- PROVIDE PRODUCT APPROVAL FOR INSWING ENTRY DOOR AS
 SHOWN ON PLANS.
 2- WINDOW MULLIONS: SPECIFY MULLION SIZE.
 NOTE: PROVIDE INFORMATION PRIOR TO INSTALLATION TO
 AVOID CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO
 BE APPROVED BY DESIGNER OF RECORD PRIOR TO SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By jgomez Date 2021-10-19 Time 17:05 Rev Time 0.00
Received By jgomez Date 2021-10-19 Time 16:39 Sent To  
Notes
2021-10-19 17:06:17BUILDING APPROVED WITH PROVISO:
 1- PROVIDE PRODUCT APPROVAL FOR INSWING ENTRY DOOR AS
 SHOWN ON PLANS.
 2- WINDOW MULLIONS: NEED TO SPECIFY MULLION SIZE.
 NOTE: PROVIDE INFORMATION PRIOR TO INSTALLATION TO
 AVOID CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO
 BE APPROVED BY DESIGNER OF RECORD PRIOR TO SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-01 Cont ID  
Sent By jgomez Date 2021-09-01 Time 15:40 Rev Time 0.00
Received By jgomez Date 2021-09-01 Time 13:37 Sent To  
Notes
2021-09-01 15:41:51RESIDENTIAL (R3) ALTERATION LEVEL 3, BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21071631
  
 NOTE:
 LEVEL 3 ALTERATION. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE AS REQUIRED
 BY SEC. 604 FBC-EXISTING BUILDING, SEC. 901.2
 FBC-EXISTING BUILDING. SEC. 801.3 FBC-EXISTING
 BUILDING.
  
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***IMPORTANT***
 ENERGY CALCULATIONS NEED TO BE CERTIFIED BY THE OWNER
 OR AUTHORIZED AGENT BEFORE ISSUING THE PERMIT.
  
  
 1-ENERGY CALCULATIONS SUBMITTED:
 A)THE ENERGY FORM R405-2020 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER, ARCHITECT OR OWNER LEGALLY
 DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION.
  
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. PROVIDE CORRECT OWNER'S NAME. THE PERMIT OFFICE
 IS CITY OF WEST PALM BEACH NOT PALM BEACH COUNTY.
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 C)REVISE ITEM #1 ON PAGE 1. THIS IS NOT NEW
 CONSTRUCTION.
 SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 D)PROVIDE CORRECT INFORMATION FOR ITEM #2. THE QUESTION
 ON THIS ITEM IS SINGLE FAMILY OR MULTIPLE FAMILY?.
 "DETACHED" IS NOT THE ANSWER. REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 E)WALL INSULATION ON ITEM #10 ON PAGE 1 DOESN'T MATCH
 WALL INSULATION SPECIFIED ON SHEET A-2. SEE PLANS AND
 REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F)CLEARLY PROVIDE THE NAME OF PERSON PERFORMING THE
 ANALYSIS AND GENERATING THE REPORT AS REQUIRED BY SEC.
 R405.4.2.1 FBC- ENERGY CONSERVATION.
  
 G)PROVIDE CORRECT INFORMATION IN THE SPACES SECTION ON
 PAGE 2. IS MISSING THE NUMBER OF OCCUPANTS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 H) ROOF TYPE AND MATERIAL SPECIFIED ON PAGE 3 IS
 MISSING THE INFORMATION FOR THE FLAT ROOF. THE ROOF OF
 THIS BUILDING IS PITCHED AND FLAT. SEE PLANS AND
 BUILDING AERIAL VIEW. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 I)REVISE WINDOWS OVERHANG DEPTH AND SEPARATION TO MATCH
 PLANS. SEE ELEVATIONS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 J) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 2- SHOW ON PLANS CARBON MONOXIDE ALARMS BY ALL THE
 BEDROOMS AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL.
  
 3- PROVIDE DOOR STRUCTURAL BUCK DETAIL SHOWING
 COMPLIANCE WITH SEC. R609.7.2.1 FBC-RESIDENTIAL.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 4- SHEET A-3: THERE ARE SEVERAL NOTES REFERENCING THE
 2014 RESIDENTIAL CODE. THE CURRENT CODE IS
 FBC-RESIDENTIAL SEVENTH EDITION (2020). REVISE ALL
 NOTES REFERENCING THE OLD CODE.
 CHAPTER 553.73 F.S.
  
 5- PROVIDE ICC EVALUATION REPORT FOR THE SPRAYED FOAM
 R-20 INSULATION TO VERIFY COMPLIANCE WITH SEC. R316
 FBC-RESIDENTIAL.
 NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE THE
 REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 6-WINDOW FALL PROTECTION SHALL BE PROVIDED ON SECOND
 FLOOR WINDOWS WHERE THE TOP OF THE WINDOW SILL OF AN
 OPERABLE WINDOW IS LOCATED LESS THAN 24" ABOVE THE
 FINISHED FLOOR . SEC. R312.2 FBC RESIDENTIAL.
 CLEARLY SPECIFY IF THERE IS ANY WINDOW WITH THE SILL
 BELOW 24".
 NOTE: IF REQUIRED, THEN WINDOW OPENING CONTROL DEVICE
 NEEDS TO COMPLY WITH ASTM F2090. PROVIDE INFORMATION
 FOR DEVICE TO BE INSTALLED.
  
 7-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)INSWING ENTRY DOOR.
 B)EXTERIOR FRENCH DOORS WITH SIDELITES AS SHOWN ON
 PLANS.
 C)WINDOWS INCLUDING THOSE WITH ARCHED TOP.
 D)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO AVOID DELAYS/CONFLICTS).
 E)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
  
 13-ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By fgiaquin Date 2021-10-26 Time 14:45 Rev Time 0.00
Received By fgiaquin Date 2021-10-26 Time 14:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-10-20 Cont ID  
Sent By fgiaquin Date 2021-10-20 Time 21:27 Rev Time 0.00
Received By fgiaquin Date 2021-10-20 Time 20:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-08-10 Cont ID  
Sent By fgiaquin Date 2021-08-10 Time 20:25 Rev Time 0.00
Received By fgiaquin Date 2021-08-10 Time 18:56 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By ccole Date 2021-10-26 Time 11:04 Rev Time 0.00
Received By ccole Date 2021-10-26 Time 10:19 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2021-10-14 Cont ID  
Sent By ccole Date 2021-10-14 Time 16:21 Rev Time 0.00
Received By ccole Date 2021-10-14 Time 12:42 Sent To  
Notes
2021-10-14 16:22:432ND REVIEW FBC-2020 RES.
 PERMIT- 21071631
 10/14/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-2 & G-1: THE NEW RISER SHOWS AN OUTDOOR GAS
 GRILL BEHIND THE GUEST HOUSE. THE GAS GRILL AND PIPING
 TO IT SHALL BE INSTALLED UNDER PERMIT 21071627 WHICH IS
 THE SEPARATE PERMIT FOR THE GUEST HOUSE WORK. THE
 CONTRACTOR AND OWNER ARE ADVISED TO CONSULT WITH FPU
 FOR INFORMATION ABOUT GAS METERING AS A SEPARATE METER
 MAY BE REQUIRED. FPU CUSTOMER SERVICE NUMBER IS
 1-800-427-7712. PLEASE REFER TO PERMIT 21071627 FOR
 COMMENTS ABOUT THE GAS GRILL.
  
 2) A-2: PLEASE SHOW THE LOCATION OF THE TANKLESS WATER
 HEATER. IF LOCATED ON THE EXTERIOR PLEASE SHOW AND THE
 REQUIRED CLEARANCE DISTANCE MEASUREMENTS TO BUILDING
 OPENINGS, TO GRADE AND OVERHEAD CONSTRUCTION- SECTION
 G2448.1 FBC RES. IF LOCATED ON THE INTERIOR, PLEASE
 PROVIDE COMBUSTION AIR AND VENTING PLANS- G2407.1,
 G2427.21 & G2448.1.
  
 3) G-1: THE EQUIPMENT INDICATES A HOME ADVANTAGE GAS
 WATER HEATER HOWEVER SPECS WERE SUBMITTED FOR A RHEEM
 UNIT. PLEASE CHOOSE ONE OR THE OTHER AND PROVIDE A
 COMPLETE SCHEDULE THAT INCLUDES THE EFFICIENCY RATING-
 G2448.1 FBC RES, AND TABLE C404.2 FBC EC.
  
 4) G-1 GAS RISER:
 A) PROVIDE THE TOTAL LENGTH OF THE PIPING, AND THE
 INDIVIDUAL BRANCH AND CUT PIPE LENGTHS- SECTION
 G2413.4.1.
 B) PROVIDE THE PIPE SIZING TABLES IN ACCORDANCE WITH
 SECTION G2413.4.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-08-13 Cont ID  
Sent By ccole Date 2021-08-13 Time 13:58 Rev Time 0.00
Received By ccole Date 2021-08-13 Time 13:50 Sent To  
Notes
2021-08-13 14:01:501ST REVIEW FBC-2020 RES.
 PERMIT- 21071631
 8/13/2021
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ELECTRICAL PLAN INDICATES A GAS WATER HEATER AND
 A GAS RANGE. PLEASE CLARIFY THE SCOPE OF WORK FOR GAS
 IN ACCORDANCE WITH SECTION 107.2.1 & 107.3.5.3 WPB.
  
 A) PROVIDE A LIST OF GAS APPLIANCES THAT ARE BEING
 REPLACED IN SAME LOCATIONS OR INSTALLED IN NEW
 LOCATIONS.
  
 B) PROVIDE EQUIPMENT SCHEDULES ON THE PLAN LISTING
 MAKES AND MODELS, AND ALSO THE EFFICIENCY RATING FOR
 THE GAS WATER HEATER- SECTIONS G2447.1 & G2448.1 FBC
 RES AND TABLE C404.1 FBC EC.
  
 C) PROVIDE A GAS RISER DRAWING FOR ALL NEW OR EXTENDED
 GAS PIPING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
2021-08-13 14:01:071ST REVIEW FBC-2020 RES.
 PERMIT- 21071464
 8/13/2021
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 PLAN REVIEW RESULTS: DENIED.
 1) THE ELECTRICAL PLAN INDICATES A GAS WATER HEATER AND
 A GAS RANGE. PLEASE CLARIFY THE SCOPE OF WORK FOR GAS
 IN ACCORDANCE WITH SECTION 107.2.1 & 107.3.5.3 WPB.
 A) PROVIDE A LIST OF GAS APPLIANCES THAT ARE BEING
 REPLACED IN SAME LOCATIONS OR INSTALLED IN NEW
 LOCATIONS.
 B) PROVIDE EQUIPMENT SCHEDULES ON THE PLAN LISTING
 MAKES AND MODELS AND EFFICIENCY RATING FOR THE GAS
 WATER HEATER- SECTIONS G2447.1 & G2448.1 FBC RES AND
 TABLE C404.1 FBC EC.
 C) PROVIDE A GAS RISER DRAWING FOR ALL NEW OR EXTENDED
 GAS PIPING.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-11-03 Cont ID  
Sent By jgomez Date 2021-11-03 Time 12:46 Rev Time 0.00
Received By jgomez Date 2021-11-03 Time 08:13 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-11-02 Cont ID  
Sent By lmarchan Date 2021-11-02 Time 08:03 Rev Time 0.00
Received By lmarchan Date 2021-11-01 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-26 Cont ID  
Sent By jgomez Date 2021-10-26 Time 17:18 Rev Time 0.00
Received By jgomez Date 2021-10-25 Time 07:55 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-20 Cont ID  
Sent By fgiaquin Date 2021-10-20 Time 21:27 Rev Time 0.00
Received By fgiaquin Date 2021-10-04 Time 09:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-01 Cont ID  
Sent By jgomez Date 2021-09-01 Time 15:45 Rev Time 0.00
Received By jgomez Date 2021-08-05 Time 09:08 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2021-11-09 Cont ID  
Sent By jgomez Date 2021-11-09 Time 12:00 Rev Time 0.00
Received By jgomez Date 2021-11-01 Time 10:11 Sent To  
Notes
2021-11-09 12:00:53RESEARCHED AND REAR PORCH ENCLOSED. PERMIT #20011325.
 JG.
2021-11-01 10:12:1811/01/21 - IMPACT FEE QUESTIONNAIRE UPLOADED - EMAILED
 IMPACT FEE OFFICE. CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-09-01 Cont ID  
Sent By jgomez Date 2021-09-01 Time 15:44 Rev Time 0.00
Received By jgomez Date 2021-09-01 Time 15:44 Sent To  
Notes
2021-09-01 15:45:10IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By medwards Date 2021-10-26 Time 08:58 Rev Time 0.00
Received By medwards Date 2021-10-26 Time 08:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-10-05 Cont ID  
Sent By medwards Date 2021-10-05 Time 16:48 Rev Time 0.00
Received By medwards Date 2021-10-05 Time 16:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-08-16 Cont ID  
Sent By medwards Date 2021-08-16 Time 14:27 Rev Time 0.00
Received By medwards Date 2021-08-16 Time 13:16 Sent To  
Notes
2021-08-16 14:29:14APPROVED WITH PRIVISO: THE MECHANICAL CONTRACTOR MUST
 ADD THEIR LICENSE TO THE MECHANICAL SUB PERMIT.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By ccole Date 2021-10-26 Time 11:04 Rev Time 0.00
Received By ccole Date 2021-10-26 Time 10:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-10-14 Cont ID  
Sent By ccole Date 2021-10-14 Time 13:25 Rev Time 0.00
Received By ccole Date 2021-10-14 Time 12:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-08-13 Cont ID  
Sent By ccole Date 2021-08-13 Time 13:49 Rev Time 0.00
Received By ccole Date 2021-08-13 Time 13:05 Sent To  
Notes
2021-08-13 13:49:541ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 21071464
 8/13/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: THE FIXTURE DRAIN FOR THE STANDPIPE
 SERVING AN AUTOMATIC CLOTHES WASHER SHALL CONNECT TO A
 3-INCH OR LARGER DIAMETER FIXTURE BRANCH OR STACK-
 SECTION 406.2 FBC P.
  
 2) A2 & P1: THE STUDOR VENT FOR THE SHOWER BE IN A
 LOCATION THAT AS ACCESS AND VENTILATION. PLEASE SHOW
 THE LOCATION- SECTION P3114.5 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By jgomez Date 2021-10-26 Time 17:18 Rev Time 0.00
Received By jgomez Date 2021-10-26 Time 17:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-05 Cont ID  
Sent By medwards Date 2021-10-05 Time 16:48 Rev Time 0.00
Received By medwards Date 2021-10-05 Time 16:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-08-16 Cont ID  
Sent By medwards Date 2021-08-16 Time 14:32 Rev Time 0.00
Received By medwards Date 2021-08-16 Time 14:32 Sent To  
Notes
2021-08-16 14:33:56SHEET M101: THE DIGITAL SIGNATURE WAS NOT VERIFIED.
 PLEASE RESUBMIT THE ORIGINAL DITITALLY SIGNED DRAWING.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved