| Plan Review Stops For Permit 21071301 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-20 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-20 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-15 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-15 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2021-09-15 09:23:34 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING - PREVIOUS COMMENTS HAVE NOT BEEN | | | ADDRESSED. | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | | FEET FROM ANY OPENINGS INTO A BUILDING. PLEASE SPECIFY | | | THIS ON THE SURVEY. | | | R303.5.1 INTAKE OPENINGS. MECHANICAL AND GRAVITY | | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | | | 2) SEE SIGNATURE REVIEW. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-25 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-25 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2021-08-25 07:50:51 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | | FEET FROM ANY OPENINGS INTO A BUILDING. PLEASE SPECIFY | | | THIS ON THE SURVEY. | | | R303.5.1 INTAKE OPENINGS. MECHANICAL AND GRAVITY | | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | | | 2) SEE SIGNATURE REVIEW. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-09-04 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-09-04 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-09-04 |
Time |
17:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-08-11 |
Time |
22:29 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-08-11 |
Time |
21:52 |
Sent To |
|
|
| Notes |
| 2021-08-11 22:29:13 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SERVICE ENTRANCE CONDUCTORS FROM METER TO ATS AND | | | FEEDER CONDUCTORS FROM ATS TO INTERIOR PANEL ARE NOT OF | | | SUFFICIENT SIZE. NEC 230 NEC 215 | | | | | | 2. PLAN MUST BE SIGNED BY QUALIFIER. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-09-20 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-09-17 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-15 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-03 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-25 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-30 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-20 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-20 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-15 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-15 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2021-09-15 09:22:14 | THE GENERATOR PAD DRAWING DOES NOT HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE. ELECTRONICALLY SUBMITTED DRAWINGS | | | ARE REQUIRED TO HAVE THE ARCHITECT OR ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S | | | ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO | | | BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF | | | THE SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | | 61G15 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-25 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-25 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2021-08-25 07:52:56 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | | 61G15 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-09-20 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-09-20 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-08-23 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-08-23 |
Time |
17:48 |
Sent To |
|
|
| Notes |
|
|