Plan Review Details - Permit 21071181
Plan Review Stops For Permit 21071181
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-09-14 Cont ID  
Sent By pvalenti Date 2021-09-14 Time 13:00 Rev Time 0.00
Received By pvalenti Date 2021-09-14 Time 12:59 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-08-10 Cont ID  
Sent By rmcphers Date 2021-08-10 Time 16:33 Rev Time 0.00
Received By rmcphers Date 2021-08-10 Time 16:33 Sent To  
Notes
2021-08-10 16:33:53PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-08-10 Cont ID  
Sent By rmcphers Date 2021-08-10 Time 16:34 Rev Time 0.00
Received By rmcphers Date 2021-08-10 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-08-06 Cont ID  
Sent By fgiaquin Date 2021-08-06 Time 22:41 Rev Time 0.00
Received By fgiaquin Date 2021-08-06 Time 21:39 Sent To  
Notes
2021-08-06 22:42:46FIRE ALARM WILL REQUIRE SEPARATE PERMITS AND PLAN
 SUBMITTALS.
 ALL LOW VOLTAGE WILL REQUIRE SEPARATE PERMITS AND PLAN
 SUBMITTALS EXCEPT DATA/CAT6 A LOW VOLTAGE DATA STOP HAS
 BEEN ADDED TO THIS REVIEW AND PASSED.

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-08-06 Cont ID  
Sent By fgiaquin Date 2021-08-06 Time 22:43 Rev Time 0.00
Received By fgiaquin Date 2021-08-06 Time 22:43 Sent To  
Notes
2021-08-06 22:43:16APPROVED FOR CAT6/DATA ONLY

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-28 Cont ID  
Sent By pleduc Date 2021-07-28 Time   Rev Time 0.00
Received By pleduc Date 2021-07-28 Time 12:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-05 Cont ID  
Sent By pvalenti Date 2021-10-05 Time 13:17 Rev Time 0.00
Received By pvalenti Date 2021-09-30 Time 11:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-16 Cont ID  
Sent By pvalenti Date 2021-09-16 Time 10:22 Rev Time 0.00
Received By pvalenti Date 2021-08-24 Time 12:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-12 Cont ID  
Sent By pvalenti Date 2021-08-12 Time 13:36 Rev Time 0.00
Received By pvalenti Date 2021-07-27 Time 12:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-08-09 Cont ID  
Sent By medwards Date 2021-08-09 Time 16:27 Rev Time 0.00
Received By medwards Date 2021-08-09 Time 16:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-10-05 Cont ID  
Sent By pvalenti Date 2021-10-05 Time 13:14 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 14:49 Sent To  
Notes
2021-10-05 13:15:2021071181 515 N FLAGLER DR # 1500
  
 PLUMBING COMMENTS: APPROVED
 .
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THATI TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21071181 515 N FLAGLER DR # 1500
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-09-16 Cont ID  
Sent By pvalenti Date 2021-09-16 Time 10:20 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 14:49 Sent To  
Notes
2021-09-16 10:21:23CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21071181 515 N FLAGLER DR # 1500
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.COMPLIED
  
 2. COMPLIED
  
 3. COMPLIED
  
 4. COMPLIED
  
 5. COMPLIED
  
 6. PARTIALLY COMPLIED: SD-2 DUAL CHECK VALVES ARE ASSE
 1032 COMPLIANT. PER FBC PL 608.3, 608.17.1.2 AND TABLE
 608.1, SAID DEVICES USED IN THE NOTED APPLICATIONS ON
 THE PLAN SHALL COMPLY WITH ASSE 1024.
 NEW COMMENT: SUBMITTED ZURN Z-700 IS ASSE 1024
 COMPLIANT AS REQUIRED. REVISED KEYNOTE 5 INDICATES ASSE
 1022; PER WPB FBC 107.2.1, CORRECT KEYNOTE 5 TO REFLECT
 ASSE 1024.
  
 7. COMPLIED
  
 8.SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE A DETAIL
 SHOWING COMPLIANCE WITH FBC PL 409.4. THE WASTE
 CONNECTION OF A RESIDENTIAL DISHWASHER SHALL CONNECT
 DIRECTLY TO A WYE BRANCH FITTING ON THE TAILPIECE OF
 THE KITCHEN SINK, DIRECTLY TO THE DISHWASHER CONNECTION
 OF A FOOD WASTE DISPOSER, OR THROUGH AN AIR BREAK TO A
 STANDPIPE. THE WASTE LINE OF A RESIDENTIAL DISHWASHER
 SHALL RISE AND BE SECURELY FASTENED TO THE UNDERSIDE OF
 THE SINK RIM OR COUNTER TOP.
 PLEASE NOTE, SPECIFIED WALL RECEPTACLE WATER-TITE
 DW1200HA FOR DISHWASHER IS NOT A COMBINATION WATER
 SUPPLY/DRAIN RECEPTACLE BOX.
  
 9. COMPLIED
  
 10. COMPLIED
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21071181 515 N FLAGLER DR # 1500
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-08-12 Cont ID  
Sent By pvalenti Date 2021-08-12 Time 13:34 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 14:49 Sent To  
Notes
2021-08-12 13:36:17CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21071181 515 N FLAGLER DR # 1500
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER WPB FBC 107.2.1, PROVIDE SIDE ELEVATION DETAIL OF
 NEW SINK. INCLUDE THE RIM OR COUNTER SURFACE 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC ACC
 606.3, TOE AND KNEE CLEARANCE AS REQUIRED BY FBC ACC
 306.2 AND 306.3.
  
 2.PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH
 A NOTE STATING, "HORIZONTAL PIPE SHALL BE SUPPORTED IN
 ACCORDANCE WITH FBC PL TABLE 308.5."
  
 3.PER WPB FBC 107.2.1, NOTE ALL COMPONENTS IN WATER
 SYSTEM SHALL BE LEAD FREE AS REQUIRED IN FBC PL 605.2,
 605.2.1.
  
 4.RE: MOISTURE SENSOR DETAIL; PER WPB FBC 107.2.1,
 PROVIDE WATER HAMMER ARRESTOR TO CONTROL WATER HAMMER
 AT SOLENOID VALVE AS REQUIRED BY FBC PL 604.9.
 ADDITIONALLY SHOW SOLENOID VALVE IN RISER DIAGRAM
  
 5.GENERAL PLUMBING NOTES; NOTE 14 CALLS FOR WATER
 HAMMER ARRESTORS TO BE INSTALLED WHERE QUICK-CLOSING
 VALVES ARE UTILIZED. NOTE PER FBC PL 604.9, WATER
 HAMMER ARRESTORS SHALL COMFORM TO ASSE 1010. NOTE THAT
 THE SPECIFIED WATER-TITE DW1200HA FOR THE DISHWASHER
 COMPLIES AS IT DOES COMFORM TO ASSE 1010. THE
 WATER-TITE AB9700 SPECIFIED FOR THE REFRIGERATOR ICE
 MAKER AND COFFEE MAKER DO NOT COMFORM TO ASSE 1010. PER
 WPB FBC 107.2.1, IF A WALL BOX IS SPECIFIED THAT IS NOT
 ASSE 1010 COMPLIANT, THEN SPECIFY AND SHOW ON THE RISER
 DIAGRAM THE REQUIRED WATER HAMMER ARRESTOR(S).
  
 6.SD-2 DUAL CHECK VALVES ARE ASSE 1032 COMPLIANT. PER
 FBC PL 608.3, 608.17.1.2 AND TABLE 608.1, SAID DEVICES
 USED IN THE NOTED APPLICATIONS ON THE PLAN SHALL COMPLY
 WITH ASSE 1024.
  
 7.PLUMBING KEYNOTE #2: CALLS FOR COLD WATER SUPPLY TO
 DISHWASHER. WATER RISER DIAGRAM CALLS FOR HOT WATER TO
 DISHWASHER. PER WPB FBC 107.2.1, CLARIFY.
  
 8.PER WPB FBC 107.2.1, PROVIDE A DETAIL SHOWING
 COMPLIANCE WITH FBC PL 409.4. THE WASTE CONNECTION OF A
 RESIDENTIAL DISHWASHER SHALL CONNECT DIRECTLY TO A WYE
 BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN SINK,
 DIRECTLY TO THE DISHWASHER CONNECTION OF A FOOD WASTE
 DISPOSER, OR THROUGH AN AIR BREAK TO A STANDPIPE. THE
 WASTE LINE OF A RESIDENTIAL DISHWASHER SHALL RISE AND
 BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK RIM
 OR COUNTER TOP.
  
 9.PER FBC PL 911.3, TABLE 911.3, THE VERTICAL DRAIN
 BETWEEN THE ADDED SINK AND THE EXISTING LAVATORY SHALL
 BE SIZED A MINIMUM 2 INCH AND SHALL CONTINUE THAT SIZE
 TO CONNECTION WITH THE HORIZONTAL BRANCH. PER WPB FBC
 107.2.1, ADD A NOTE STATING THE NEW SINK AND EXISTING
 LAVATORY ARE COMMON VENTED IN ACCORDANCE WITH FBC PL
 911.
  
 10.REGARDING POINT OF USE WATER HEATER DETAIL:
 ?.A)PER WPB FBC 107.2.1, REVISE ? INCH HW TO ADJACENT
 OR BACK TO BACK FIXTURE TO STATE ? INCH HW TO
 DISHWASHER
 ?.B)COLD WATER TO SINK AND WATER HEATER; PER FBC PL
 606.2 AND 503.1, PROVIDE A TEE BETWEEN THE WALL STUB
 OUT AND THE TWO FIXTURES. PROVIDE A DEDICATED SHUT OFF
 VALVE BETWEEN THE TEE AND SINK. PROVIDE A DEDICATED
 SHUT-OFF VALVE BETWEEN THE TEE AND THE WATER HEATER.
 ?.C)HOT WATER TO SINK AND DISHWASHER; PER FBC PL 606.2,
 PROVIDE A DEDICATED SHUT OFF VALVE BETWEEN THE TEE AND
 SINK.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21071181 515 N FLAGLER DR # 1500
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-10-05 Cont ID  
Sent By pvalenti Date 2021-10-05 Time 13:17 Rev Time 0.00
Received By pvalenti Date 2021-10-05 Time 13:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-09-14 Cont ID  
Sent By pvalenti Date 2021-09-14 Time 13:06 Rev Time 0.00
Received By pvalenti Date 2021-09-14 Time 13:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-10 Cont ID  
Sent By rmcphers Date 2021-08-10 Time 16:39 Rev Time 0.00
Received By rmcphers Date 2021-08-10 Time 16:39 Sent To  
Notes
***NONE***