Plan Review Details - Permit 21071167
Plan Review Stops For Permit 21071167
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-03-05 Cont ID  
Sent By cpuell Date 2022-03-05 Time 10:58 Rev Time 0.00
Received By cpuell Date 2022-03-05 Time 10:58 Sent To  
Notes
2022-03-05 10:58:542471 OKEECHOBEE BLVD DOESN'T HAVE A & B DESIGNATORS,
 UPDATED PERMIT TO REMOVE THE A SUITE, THE AREA OF WORK
 IS FOR 2471 OKEECHOBEE BLVD

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status P Date 2022-02-15 Cont ID  
Sent By rmcphers Date 2022-02-15 Time 10:37 Rev Time 0.00
Received By rmcphers Date 2022-02-15 Time 10:37 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2022-01-18 Cont ID  
Sent By rmcphers Date 2022-01-18 Time 16:58 Rev Time 0.00
Received By rmcphers Date 2022-01-18 Time 16:58 Sent To  
Notes
2022-01-18 16:58:55PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-12-21 Cont ID  
Sent By rmcphers Date 2021-12-21 Time 09:08 Rev Time 0.00
Received By rmcphers Date 2021-12-21 Time 09:08 Sent To  
Notes
2021-12-21 09:09:44PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 15:06 Rev Time 0.00
Received By rmcphers Date 2021-09-21 Time 13:41 Sent To  
Notes
2021-09-21 15:14:05PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-02-16 Cont ID  
Sent By rmcphers Date 2022-02-16 Time 16:37 Rev Time 0.00
Received By rmcphers Date 2022-02-16 Time 16:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-02-15 Cont ID  
Sent By rmcphers Date 2022-02-15 Time 10:37 Rev Time 0.00
Received By rmcphers Date 2022-02-15 Time 10:37 Sent To  
Notes
2022-02-15 10:38:22RESTAURANT REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
  
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 1) DRAWINGS SHOW A NEW EXTERIOR FRONT DOOR - PLEASE
 PROVIDE A COMPLETE (FRONT PAGES AND THE INSTALLATION
 INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE PRODUCT
 APPROVAL - ALL PRODUCT APPROVALS NEED TO BE REVIEWED
 AND MARKED APPROVED BY THE DESIGNER OF RECORD - FBC WPB
 107.3.4
 OR PROVIDE A NOTE ON THE DRAWINGS THAT THE EXTERIOR
 DOOR PRODUCT APPROVAL WILL BE A DEFERRED SUBMITTAL.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-01-18 Cont ID  
Sent By rmcphers Date 2022-01-18 Time 16:58 Rev Time 0.00
Received By rmcphers Date 2022-01-18 Time 16:51 Sent To  
Notes
2022-01-18 16:58:02RESTAURANT REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
  
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 1) I MISSED THIS - DRAWINGS SHOW A NEW EXTERIOR FRONT
 DOOR - PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD
 - FBC WPB 107.3.4
 OR PROVIDE A NOTE ON THE DRAWINGS THAT THE EXTERIOR
 DOOR PRODUCT APPROVAL WILL BE A DEFERRED SUBMITTAL.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-12-21 Cont ID  
Sent By rmcphers Date 2021-12-21 Time 09:06 Rev Time 0.00
Received By rmcphers Date 2021-12-21 Time 09:06 Sent To  
Notes
2021-12-21 09:07:00RESTAURANT REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 2ND REVIEW - NO CHANGES
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE PER FBC
 CHAPTER 6
 2) PLEASE SHOW SPRINKLERED OR NON SPRINKLERED.
 3) PLEASE SHOW IF TERMITE PROTECTION IS REQUIRED AT THE
 CONCRETE FLOOR REPLACEMENT AREAS FBC 1816.1.2
 4) JOB VALUE SHOWN ON THE BUILDING PERMIT APPLICATION
 APPEARS TO BE LOW - PLEASE REVISE THE BUILDING PERMIT
 APPLICATION TO SHOW THE CORRECT JOB VALUE - FBC WPB
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION
 OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 15:15 Rev Time 0.00
Received By rmcphers Date 2021-09-21 Time 13:41 Sent To  
Notes
2021-09-21 15:14:26RESTAURANT REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE PER FBC
 CHAPTER 6
 2) PLEASE SHOW SPRINKLERED OR NON SPRINKLERED.
 3) PLEASE SHOW IF TERMITE PROTECTION IS REQUIRED AT THE
 CONCRETE FLOOR REPLACEMENT AREAS FBC 1816.1.2
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-09-01 Cont ID  
Sent By jleahy Date 2021-09-01 Time 12:43 Rev Time 0.00
Received By jleahy Date 2021-09-01 Time 12:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-02-24 Cont ID  
Sent By   Date 2022-02-24 Time   Rev Time 0.00
Received By jcclark Date 2022-02-24 Time 11:43 Sent To  
Notes
2022-02-24 11:44:46SEE PREVIOUS NOTES FROM CHIEF LEDUC
 JOSEPH CLARK
2022-02-24 11:44:06SEE PREVIOUS NOTES CLARK

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-06 Cont ID  
Sent By   Date 2022-01-06 Time   Rev Time 0.00
Received By jcclark Date 2022-01-06 Time 12:16 Sent To  
Notes
2022-01-06 12:21:16PASSED PENDING PREVIOUS PROVISO IS STILL IN EFFECT BY
 CHIEF LEDUC.
  
 PER CITY CODE, ALL WORK IS SUBJECT TO FIELD INSPECTIONS
 AND APPROVAL
  
 JOSEPH CLARK
 OFFICE OF THE FIRE MARSHAL
 561-804-4748
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-28 Cont ID  
Sent By pleduc Date 2021-07-28 Time   Rev Time 0.00
Received By pleduc Date 2021-07-28 Time 16:32 Sent To  
Notes
2021-07-28 16:32:35FIRE PROVISO:
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM SYSTEM,
 INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE PERMIT
 AND SHOP DRAWINGS
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-02-25 Cont ID  
Sent By aoliver Date 2022-02-25 Time 09:10 Rev Time 0.00
Received By aoliver Date 2022-02-16 Time 07:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-02-15 Cont ID  
Sent By rmcphers Date 2022-02-15 Time 10:39 Rev Time 0.00
Received By rmcphers Date 2022-01-20 Time 07:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-01-19 Cont ID  
Sent By rmcphers Date 2022-01-19 Time 07:40 Rev Time 0.00
Received By rmcphers Date 2022-01-04 Time 09:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-23 Cont ID  
Sent By rmcphers Date 2021-12-23 Time 11:24 Rev Time 0.00
Received By rmcphers Date 2021-12-02 Time 15:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 15:15 Rev Time 0.00
Received By rmcphers Date 2021-07-27 Time 15:48 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-03-03 Cont ID  
Sent By lmarchan Date 2022-03-03 Time 14:28 Rev Time 0.00
Received By lmarchan Date 2022-02-25 Time 12:34 Sent To  
Notes
2022-03-03 14:29:49NO IMPACT FEES DUE. LEM
2022-02-25 12:34:232/25/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 13:41 Rev Time 0.00
Received By rmcphers Date 2021-09-21 Time 13:41 Sent To  
Notes
2021-09-21 13:42:23PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-08-23 Cont ID  
Sent By medwards Date 2021-08-23 Time 16:48 Rev Time 0.00
Received By medwards Date 2021-08-23 Time 16:48 Sent To  
Notes
2021-08-23 16:49:05NO MECHANICAL WORK SHOWN ON DRAWINGS FOR THIS PROJECT.
 ME

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-12-23 Cont ID  
Sent By ccole Date 2021-12-23 Time 11:14 Rev Time 0.00
Received By ccole Date 2021-12-23 Time 10:13 Sent To  
Notes
2021-12-23 11:18:47RESTROOM AND PLUMBING WORK REMOVED FROM SCOPE.

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-08-10 Cont ID  
Sent By pvalenti Date 2021-08-10 Time 16:41 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 14:50 Sent To  
Notes
2021-08-10 16:42:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21071167 2471 OKEECHOBEE BLVD #A
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6 PROVIDE PLAN AND ELEVATION DETAILS
 FOR NEW TOILET ROOM INDICATING THE FOLLOWING:
 ?.A)PROVIDE DETAIL FOR ACCESSIBLE LAVATORIES.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC ACC
 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 ?.B)PROVIDE LOCATIONS AND DETAIL FOR ACCESSIBLE
 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES OR
 COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF
 THE REFLECTING SURFACE40 INCHES (1015 MM) MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 603.3.
 ?.C)PROVIDE DIMENSIONED FLOOR PLAN OF AFFECTED PUBLIC
 RESTROOMS. PER FBC ACC 602.2 SHOW ALL REQUIRED CLEAR
 FLOOR SPACES COMPLYING WITH 305 AND TURNING SPACES
 COMPLYING WITH 304.3.1 OR 304.3.2.
  
 2.RE: PLAN SHEET CS1-0; INDEX OF DRAWINGS DOES NOT LIST
 SUBMITTED PLAN SHEETS E0.0 LEGENDS & KEYNOTES AND MP1.0
 MECH & PLUMBING. PER WPB FBC 107.2, REVISE TO REFLECT.
  
 3.ARCHITECTURAL INDICATE PUBLIC RESTROOMS AND SINGLE
 USE RESTROOM ARE NOT IN THE SCOPE OF WORK/CONTRACT AND
 DEMO PLANS SEEM TO INDICATE THE SAME. MP1.0 AND
 ELECTRICAL DRAWINGS INDICATE THE PUBLIC RESTROOMS ARE
 IN THE SCOPE OF WORK/CONTRACT. ELECTRICAL DRAWINGS ALSO
 INDICATE THE SINGLE USE RESTROOM IS IN THE SCOPE OF
 WORK/CONTRACT; MP1.0 DOES NOT. PER WPB FBC 107.2.1,
 CLARIFY.
  
 4.PER WPB FBC 107.2.1, SHOW EXISTING DRINKING FOUNTAIN
 WITH DESCRIPTION OF THE SAME (I.E. BI-LEVEL ADA
 COMPLIANT).
  
 5. MP1.0 PLUMBING PLAN NOTE 1 INDICATES BUT DOES NOT
 DIRECTLY STATE THAT MODIFICATION OF IN-WALL PLUMBING
 MAY BE REQUIRED TO REPLACE EXISTING PLUMBING FIXTURES
 WITH THE NEW FIXTURES. IT IS ASSUMED THAT THIS WOULD BE
 CAUSED BY CHANGED ROUGH IN ELEVATIONS OR MINOR OFF-SETS
 WITH-OUT CHANGE TO THE ORIGINAL PIPING INTENT (I.E.,
 ADDING, DELETING VENTS, FIXTURE BRANCHES, ETC.) IF THIS
 IS THE CASE, NEW PLUMBING PIPING PLAN VIEW AND RISER
 DIAGRAMS ARE NOT REQUIRED. HOWEVER, AN IN-WALL ROUGH-IN
 INSPECTION WILL BE REQUIRED. PER WPB FBC 107.2.1,
 CONFIRM THE INTENT OF THE NOTE.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21071167 2471 OKEECHOBEE BLVD #A
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-02-16 Cont ID  
Sent By rmcphers Date 2022-02-16 Time 16:38 Rev Time 0.00
Received By rmcphers Date 2022-02-16 Time 16:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-02-15 Cont ID  
Sent By rmcphers Date 2022-02-15 Time 10:39 Rev Time 0.00
Received By rmcphers Date 2022-02-15 Time 10:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-01-19 Cont ID  
Sent By rmcphers Date 2022-01-19 Time 07:38 Rev Time 0.00
Received By rmcphers Date 2022-01-19 Time 07:38 Sent To  
Notes
2022-01-19 07:40:43SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING E3.0 DOES NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-09-20 Cont ID  
Sent By medwards Date 2021-09-20 Time 14:10 Rev Time 0.00
Received By medwards Date 2021-09-20 Time 14:09 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-02-23 Cont ID  
Sent By llouie Date 2022-02-23 Time   Rev Time 0.00
Received By llouie Date 2022-02-23 Time   Sent To  
Notes
2022-02-23 11:12:32* SEPARATE PERMIT REQURIED FOR REPLACEMENT WALL SIGNAGE
 (NOTED IN THE PERMIT PLANS).

Review Stop Z ZONING
Rev No 2 Status P Date 2022-01-07 Cont ID  
Sent By llouie Date 2022-01-07 Time   Rev Time 0.00
Received By llouie Date 2022-01-07 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-08-06 Cont ID  
Sent By llouie Date 2021-08-06 Time   Rev Time  
Received By llouie Date 2021-08-06 Time   Sent To  
Notes
***NONE***