| Plan Review Stops For Permit 21071155 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-16 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-16 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2022-02-16 10:21:00 | REAR UNIT GIVEN A NEW ADDRESS OF 3810 WESTVIEW AVE TO | | | REPLACE 3808 WESTVIEW AVE 3, 3808 WESTVIEW AVE 1 AND 2 | | | RETIRED. UPDATED PERMIT |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-25 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-01-25 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2022-01-25 11:26:22 | CURRENTLY OUR SYSTEMS ARE SHOWING INCORRECT | | | CONFIGURATIONS, BASED ON THE PERMIT 19120887, THE FRONT | | | HOUSE IS NO LONGER A DUPLEX, HOWEVER WE HAVE THE REAR | | | GARAGE APARTMENT LISTED AS A UNIT, THIS REAR BUILDING | | | NEEDS TO BE READDRESSED. PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO DISCUSS THE | | | ADDRESSING OPTIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-27 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-27 |
Time |
17:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-18 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-18 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2022-03-18 09:25:17 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21071155 | | | | | | NOTE: | | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | A)EXTERIOR DOOR AS SHOWN ON PLANS. | | | B)WINDOWS AS SHOWN ON PLANS. | | | | | | 2-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. UPDATE VALUATION TO INCLUDE ALL COSTS, | | | INCLUDING DESIGN PROFESSIONAL FEES. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-28 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-02 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-02 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2022-09-02 12:27:18 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; | | | | | | FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-23 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-23 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2022-05-23 13:34:40 | ELECTRIC REVIEW FAILED | | | 1)PLEASE PROVIDE ELECTRICAL FLOOR PLAN REMOVED FROM | | | VERSION 2. FBC 107.2 | | | 2)IT APPEARS RISER DIAGRAM IS INCORRECT. IT DETAILS 2 | | | SETS OF 3/0 CONDUCTORS TO A 125-AMP PANEL. IT DOES NOT | | | DETAIL WHETHER, IF THEY REALLY EXIST, THEY ARE AL OR CU | | | CONDUCTORS PLEASE DETAIL WHETHER THIS IS A MAIN PANEL | | | OR A DISCONNECT ONLY. PLEASE DETAIL WHETHER A BRANCH | | | CIRCUIT PANEL IS EXISTING ON THE INTERIOR OF THE MAIN | | | HOUSE. NEC 215.5 AND FBC 107.2 | | | 3) PLEASE DETAIL SMOKE/CARBON ALARMS AS REQUIRED FBC | | | 553.883 | | | 4) PLEASE DETAIL THE REQUIRED GROUNDING ELECTRODE | | | SYSTEM AT PANEL B AS REQUIRED. NEC 250.32 | | | 5) PLEASE DETAIL THE 2 REQUIRED SMALL APPLIANCE | | | CIRCUITS REQUIRED AT THE KITCHEN AS REQUIRED NEC | | | 210.11(C)(1) ON FLOOR PLAN AND LOAD CALCULATION | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-31 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-31 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2022-01-31 16:19:16 | ELECTRICAL REVIEW FAILED | | | 1) PROVIDE UPSTREAM ELECTRIC PANEL LOCATION (SITE | | | PLAN), LOAD CALCULATIONS AND FEEDER DIAGRAMS NEC 215.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-06-02 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-06-02 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-01-24 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-01-24 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-08 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-02 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-23 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-27 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-04 |
Time |
19:36 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-18 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-01-19 |
Time |
09:49 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-27 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-27 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2022-06-27 18:33:12 | PLAT CITY RECORDS SHOWS APT/GARAGE. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-18 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-18 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2022-03-18 09:27:09 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-10 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-10 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-20 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-20 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2022-01-20 09:04:05 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21071155 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS | | | NEWLY CONDITIONED SPACE. FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7.1 | | | | | | 3) PLEASE SHOW THAT THE THROUGH THE WALL UNIT IS | | | PROVIDING THE REQUIRED HEAT FOR THIS SPACE. FBC RES | | | R303.10 | | | | | | 4) PLEASE SHOW THE BATH EXHAUST FAN, CFM?S AND EXHAUST | | | DUCT TERMINATION LOCATION. FBC RES M1507.4 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-01-25 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-01-25 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-28 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-02 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-02 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-23 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-23 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-18 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-18 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-01-24 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-01-24 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|