| Plan Review Stops For Permit 21071098 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-12 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-12 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2021-10-12 10:30:05 | APPLICATIONS AND PLANS ALL HAD CONFLICTING ADDRESSES. | | | CORRECT ADDRESS IS 1741 PALM BEACH LAKES BLVD E243, | | | UPDATED THE PLANS AND APPLICATION FORM. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-10-19 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-09-15 |
Time |
16:43 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-15 16:43:30 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected] THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-11-09 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-11-09 13:13:53 | SUPPLEMENT 002 BUILDING J-10 WAS BUILT UNDER THE 2010 | | | FBC-BUILDING, AND ASCE 7-10. THE PLAN INDICATES THE | | | PRODUCT APPROVAL TO BE FL 12882-R1 EXTERIOR SWING DOOR | | | AND FL 14218-R3 STOREFRONT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-10-19 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-19 13:44:43 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21071098 | | | ADD: 1781 PALM BEACH LAKES BLVD. SUITE W28 | | | CONT: OTHERS CONSTRUCTION CO. | | | TEL: 561-262-4088 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. OCT. 19TH/ 2021 | | | ACTION: DENIED | | | | | | 1) SEMI-COMPLIED. SUBMITTED THIS REVIEW SUPPLEMENT 002 | | | PROVIDING BUILDING J-10 WAS BUILT UNDER THE 2010 | | | FBC-BUILDING, AND ASCE 7-10. THE PLAN INDICATES THE | | | PRODUCT APPROVAL TO BE FL 12882-R1 EXTERIOR SWING DOOR | | | AND FL 14218-R3 STOREFRONT. PLEASE SUBMIT THESE PRODUCT | | | APPROVALS AND TECHNICAL SHEETS IDENTIFYING THE OPENING | | | WIDTH & HEIGHT, SILL HEIGTH, TYPE OF GLAZING, MULLION | | | SIZE, LENGTH IF UNREINFORCED OR REINFORCED INFORMATION | | | IF REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR | | | EACH OPENING SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. | | | WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH | | | APPROVED MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND | | | SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND | | | SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING | | | USED IN THE TESTS. | | | | | | PLEASE NOTE YOU MAY REQUEST A RECORDS RESEARCH REQUEST | | | FOR THE APPROVED PRODUCT APPROVALS AND STOREFRONT SHOP | | | DRAWINGS. THEY ARE FOUND UNDER REVISION 13080564. | | | RECORD RESEARCH REQUEST GO TO MR. CRAIG MCPHERSON | | | TELEPHONE NUMBER 561-805-6684. THERE MAYBE A FEE | | | INVOLVED DEPENDING ON THE AMOUNT OF TIME IT TAKES TO | | | RETRIEVE YOUR REQUEST. | | | | | | 1ST ROUND OF COMMENTS. SHEET D-1 & A-8 DETAIL A | | | INDICATES THE REMOVAL OF THE STOREFRONT DOORS AND A | | | WINDOW, THEN RELOCATE IN A DIFFERENT LOCATION. TO REUSE | | | THE STOREFRONT SYSTEM YOU MAY OBTAIN THE ORIGINAL | | | PRODUCT APPROVALS WHEN THE GLAZING SYSTEM WAS INSTALLED | | | OR YOU MAY HAVE AN ENGINEER CERTIFY THE INSTALLATION BY | | | PROVIDING A RATIONAL ANALYSIS FOR THE ANCHORING SYSTEM | | | AND ALSO DETERMINE IF THE INSTALLATION IS LARGE MISSILE | | | IMPACT GLAZING. 104.11 ALTERNATE MATERIALS AND METHODS. | | | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-09-15 |
Time |
16:42 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-15 16:42:53 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21071098 | | | ADD: 1781 PALM BEACH LAKES BLVD. SUITE W28 | | | CONT: OTHERS CONSTRUCTION CO. | | | TEL: 561-262-4088 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. SEPT. 15 / 2021 | | | ACTION: DENIED | | | | | | 1) SHEET D-1 & A-8 DETAIL A INDICATES THE REMOVAL OF | | | THE STOREFRONT DOORS AND A WINDOW, THEN RELOCATE IN A | | | DIFFERENT LOCATION. TO REUSE THE STOREFRONT SYSTEM YOU | | | MAY OBTAIN THE ORIGINAL PRODUCT APPROVALS WHEN THE | | | GLAZING SYSTEM WAS INSTALLED OR YOU MAY HAVE AN | | | ENGINEER CERTIFY THE INSTALLATION BY PROVIDING A | | | RATIONAL ANALYSIS FOR THE ANCHORING SYSTEM AND ALSO | | | DETERMINE IF THE INSTALLATION IS LARGE MISSILE IMPACT | | | GLAZING. 104.11 ALTERNATE MATERIALS AND METHODS. | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-10-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-10-09 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-10-09 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-13 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2021-10-13 12:58:55 | ANY AND ALL WORK ON FIRE ALARM AND SPRINKLER SYSTEMS | | | SHALL BE DONE BY A FIRE ALARM CONTRACTOR UNDER SEPARATE | | | PERMITS. SEPARATE SHOP DRAWINGS ARE REQUIRED TO BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION | | | BUREAU PRIOR TO ANY INSTALLATION. | | | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-09-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2021-09-02 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2021-09-02 14:00:11 | ANY AND ALL WORK ON FIRE ALARM AND SPRINKLER SYSTEMS | | | SHALL BE DONE BY A FIRE ALARM CONTRACTOR UNDER SEPARATE | | | PERMITS. SEPARATE SHOP DRAWINGS ARE REQUIRED TO BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION | | | BUREAU PRIOR TO ANY INSTALLATION. | | | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-23 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-23 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-11-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2021-11-01 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-10-12 |
Time |
06:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-10-09 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-08-26 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-15 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-09 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2021-11-15 14:01:17 | MU-2021-054024 - $0.00 DUE LEM | | 2021-11-09 16:46:12 | 11/9/21 EMAILED IMPACT FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-10-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-09 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-09 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2021-10-09 16:30:46 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2021-10-21 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2021-10-21 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-01 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-01 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2021-09-01 16:44:18 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21071098 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE ADD A NOTE ON THE DRAWINGS STATING ALL | | | REFRIGERATION SHALL HAVE A SEPARATE PERMIT APPLICATION, | | | DRAWINGS AND PLAN REVIEW. THE REFRIGERATION WILL NOT BE | | | REVIEWED UNDER THIS PERMIT. | | | | | | 2) PLEASE PROVIDE DETAILS FOR THE OVEN. DO THE SPECS | | | REQUIRE A HOOD OVER THIS OVEN? FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-09 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-08 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-10-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-26 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-26 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2021-10-26 14:10:40 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21071098 | | | 10/26/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH NOTES ADDED IN CAP | | | LETTERS. | | | | | | 1) FAILED. SHEETS P1 & P2: REFER TO SECTION 1003.3.3.1 | | | FBC P AND REMOVE THE DRAINAGE FROM THE HAND SINKS, ICE | | | MAKER, ICE BINS, AND WIC/WIF CONDENSATE FROM THE GREASE | | | WASTE LINE. GREASE INTERCEPTORS SHALL RECEIVE DRAINAGE | | | ONLY FROM FIXTURES AND EQUIPMENT WITH GREASE-LADEN | | | WASTE. PLEASE RELOCATE HE DRAINAGE FROM THE ABOVE | | | FIXTURES AND EQUIPMENT TO THE SANITARY LINE EXCEPT FOR | | | THE CONDENSATE WHICH IS PROHIBITED FROM DRAINING INTO | | | THE SYSTEM PER SEC. 90-126 WPB CODE OF ORDINANCES. THE | | | CONDENSATE SHALL DRAIN INTO THE STORM SYSTEM, DRYWELL | | | OR PERMEABLE GROUND. THE MOP SINK AND PREP SINK SHALL | | | DRAIN INTO THE GREASE WASTE INTERCEPTOR- SECTION | | | 1003.3.1 FBC P. | | | | | | 3) FAILED. P1 & P2: PROVIDE AN INDIRECT WASTE DETAIL | | | FOR THE 3-COMPARTMENT SINK- SECTION 802.1.1 FBC P. EACH | | | WELL OF THE 3-COMPARTMENT SINK SHALL DRAIN | | | INDEPENDENTLY INTO THE FLOOR SINK- SECTION 802.1.1. FBC | | | P. | | | | | | 5) FAILED P1 & P2: PROVIDE A FILTERED WATER ISOMETRIC. | | | SHOW THE TYPE OF PIPING, PIPING RUNS TO FIXTURES AND | | | EQUIPMENT, AND LOCATIONS OF WATER HAMMER ARRESTORS AND | | | BACKFLOW PREVENTERS- SECTIONS 604.9 & 608.3 FBC P. | | | BACKFLOW PREVENTER IS REQUIRED FOR THE SUPPLY LINE TO | | | THE FILTER (P17)- SECTION 608.3.1 FBC P. | | | | | | NEW COMMENTS. | | | | | | 1) SHEET P1- WATER RISER: REMOVE THE ASSE 1024 | | | REFERENCE AT THE RPZA BY THE ICE MAKER. AN RPZ SHALL | | | MEET THE ASSE 1013 STANDARD- TABLE 608.3 FBC P. | | | | | | 2) P1 & P2: THE SUPPLY LINES TO THE DISPENSERS LISTED | | | IN THE BACKFLOW MATRIX ON P2 ARE NOT SHOWN ON THE WATER | | | RISER- SECTION 107.2.1 WPB. | | | | | | 3) P2 BACKFLOW MATRIX: THE WATTS DCDA MODELS ARE NOT | | | RPZ?S- PLEASE CORRECT- TABLE 608.3 FBC P. A) LIST THE | | | MAKE AND MODEL OF THE DUAL CHECK VALVE LISTED AS 7 IN | | | THE MATRIX- TABLE 608.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-27 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2021-09-27 17:52:57 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21071098 | | | 9/27/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P1 & P2: REFER TO SECTION 1003.3.3.1 FBC P | | | AND REMOVE THE DRAINAGE FROM THE HAND SINKS, ICE MAKER, | | | ICE BINS, AND WIC/WIF CONDENSATE FROM THE GREASE WASTE | | | LINE. GREASE INTERCEPTORS SHALL RECEIVE DRAINAGE ONLY | | | FROM FIXTURES AND EQUIPMENT WITH GREASE-LADEN WASTE. | | | PLEASE RELOCATE HE DRAINAGE FROM THE ABOVE FIXTURES AND | | | EQUIPMENT TO THE SANITARY LINE EXCEPT FOR THE | | | CONDENSATE WHICH IS PROHIBITED FROM DRAINING INTO THE | | | SYSTEM PER SEC. 90-126 WPB CODE OF ORDINANCES. THE | | | CONDENSATE SHALL DRAIN INTO THE STORM SYSTEM, DRYWELL | | | OR PERMEABLE GROUND. | | | | | | 2) P1 & P2: THE GREASE WASTE DRAINAGE LOAD FROM THE | | | TENANT SPACE INTO THE EXISTING INTERCEPTOR APPEARS TO | | | HAVE INCREASED. PROVIDE GREASE WASTE CALCULATIONS IN | | | ACCORDANCE WITH SECTIONS 1003.3.4 OR 1003.3.6 FBC P. | | | PLEASE INDICATE THE CAPACITY OF THE EXISTING | | | INTERCEPTOR AND VERIFY NO INCREASE IN SIZE WILL BE | | | REQUIRED. | | | | | | 3) P1 & P2: PROVIDE AN INDIRECT WASTE DETAIL FOR THE | | | 3-COMPARTMENT SINK- SECTION 802.1.1 FBC P. | | | | | | 4) P1 & P2: SHOW THE LOCATIONS OF WATER HAMMER | | | ARRESTORS IN THE RISER DRAWING- SECTION 604.9 FBC P. | | | | | | 5) P1 & P2: PROVIDE A FILTERED WATER ISOMETRIC. SHOW | | | THE TYPE OF PIPING, PIPING RUNS TO FIXTURES AND | | | EQUIPMENT, AND LOCATIONS OF WATER HAMMER ARRESTORS AND | | | BACKFLOW PREVENTERS- SECTIONS 604.9 & 608.3 FBC P. | | | | | | 6) P1 & P2: SHOW THE SUPPLY LINE TO THE CHEMICAL | | | DISPENSER IN THE DRAWINGS, AND THE TYPE OF BACKFLOW | | | PREVENTER TO BE INSTALLED. SHOW THE MAKE AND MODEL IN | | | THE SCHEDULE- SECTION 608.3 FBC P. | | | | | | 7) P1 & P2: PROVIDE THE EFFICIENCY RATING OF THE WATER | | | HEATER- SECTION C404.2 FBC EC. PROVIDE AN ENLARGED | | | WATER HEATER PIPING DETAIL SHOWING THE LOCATIONS OF | | | CONTROL VALVES AND THE REQUIRED THERMAL EXPANSION TANK- | | | SECTION 607.3 FBC P. | | | | | | 8) P2: REFER TO TABLE C403.2.10 FBC EC AND CORRECT NOTE | | | 4 INDICATING THE 1/2-INCH THICK PIPE INSULATION. | | | | | | 9) P1 & P2: PLACE A NOTE TO INDICATE A SEPARATE PERMIT | | | IS REQUIRED FOR THE WATER SERVICE BACKFLOW PREVENTER- | | | SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-23 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-23 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2021-11-23 11:47:00 | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS APPROVED, | | | ROUTED TO STORAGE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-11-09 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-11-09 13:20:49 | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) THE | | | SUBMITTED PLANS IN THE PLAN FOLDER, ARE EITHER SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEE?S SIGNATURE SHALL NOT BE USED ON DIGITALLY | | | SIGNED AND SEALED ENGINEERING PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-10-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-26 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-26 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2021-10-26 14:18:59 | 2ND SIGNATURE REVIEW | | | PERMIT- 21071098 | | | 10/26/21 | | | | | | THIS IS THE 2ND REQUEST FOR DIGITALLY SIGNED AND SEALED | | | PLANS TO BE SUBMITTED IN ACCORDANCE WITH FLORIDA | | | STATUTES 471.025 AND 481.221, AND FAC 61G15-23.005 & | | | 61G1-16.005. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | SIGNATURE REVIEW | | | 9/21/21 | | | | | | THIS IS A DIGITALLY SUBMITTED PROJECT BUT THE DOCUMENTS | | | HAVE A COPY OF A WET SEAL FROM THE DESIGNER. PLEASE | | | PROVIDE DIGITALLY SIGNED AND SEALED DOCUMENTS FROM THE | | | DESIGNER. F.S. 471,481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-01 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-01 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2021-09-01 16:47:02 | THIS IS A DIGITALLY SUBMITTED PROJECT BUT THE DOCUMENTS | | | HAVE A COPY OF A WET SEAL FROM THE DESIGNER. PLEASE | | | PROVIDE DIGITALLY SIGNED AND SEALED DOCUMENTS FROM THE | | | DESIGNER. F.S. 471,481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
eshneide |
Date |
2021-10-25 |
Time |
14:06 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2021-10-25 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|