Plan Review Details - Permit 21071042
| Plan Review Stops For Permit 21071042 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-21 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-21 |
Time |
06:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-24 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-24 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2021-07-24 10:18:35 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1010.1.10, PROVIDE THE OCCUPANCY | | | CLASSIFICATIONS THAT THIS BUILDING SERVES. IF THIS | | | BUILDING INCLUDES ASSEMBLY OCCUPANCY (SUCH AS AN | | | AUDITORIUM OR A CAFETERIA) AND THE OCCUPANT LOAD IS 50 | | | OR MORE, PANIC HARDWARE IS REQUIRED. REVISE THE PLAN TO | | | SHOW OCCUPANCY CLASSIFICATIONS AND OCCUPANT LOAD FOR | | | THOSE OCCUPANCIES, OR REVISE DOCUMENTS TO INCLUDE PANIC | | | HARDWARE. | | | | | | 2. FBC A 404.2.5, PAGE 9 OF THE DOOR PRODUCT APPROVAL | | | PROPSES A 4" BUMPER THRESHOLD WITH A STATEMENT THAT | | | "ADA COMPLIANT TO BE REVIEWED BY BUILDING OFFICIAL". | | | THIS PERMIT WILL BE REDLINED THAT COMPLIANCE WILL BE | | | FIELD VERIFIED. | | | | | | THRESHOLD SHALL BE 1/2" MAX. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-08-10 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-08-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2021-08-10 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-08-10 11:56:35 | PER SUBMITTED REVISION, THIS DOOR INSTALLATION DOES NOT | | | SERVE AS AN EXIT IN THE EGRESS PLAN. DOOR ASSEMBLY | | | MEETS REQUIREMENTS FOR CODE | | | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-26 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2021-07-26 12:53:03 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE PROPOSED DOOR INSTALL IS WITHIN AN ASSEMBLY | | | OCCUPANCY. | | | | | | THERE ARE NO INDICATIONS OF THE REQUIRED EXIT DOOR | | | HARDWARE INDICATED IN THE CODE BELOW. | | | | | | PER NFPA 101, CHAPTER 13, EXISTING OCCUPUCANCIES. | | | | | | 13.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM | | | AN AREA HAVING | | | AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE | | | PERMITTED TO BE PROVIDED | | | WITH A LATCH OR LOCK ONLY IF THE LATCH OR LOCK IS PANIC | | | HARDWARE OR | | | FIRE EXIT HARDWARE COMPLYING WITH 7.2.1.7, UNLESS | | | OTHERWISE PERMITTED | | | BY ONE OF THE FOLLOWING: | | | (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS | | | ELECTRICAL LOCKING | | | SYSTEMS AS PERMITTED IN 13.2.2.2.5. | | | (2) THIS REQUIREMENT SHALL NOT APPLY TO SENSOR-RELEASE | | | OF ELECTRICAL | | | LOCKING SYSTEMS AS PERMITTED IN 13.2.2.2.6. | | | 13.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5 | | | SHALL BE PERMITTED | | | TO BE USED ON A SINGLE DOOR OR A SINGLE PAIR OF DOORS | | | IF BOTH OF THE FOLLOWING | | | CONDITIONS APPLY: | | | (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT | | | FROM ASSEMBLY | | | OCCUPANCIES HAVING AN OCCUPANT LOAD NOT GREATER THAN | | | 600. | | | (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN | | | ASSEMBLY OCCUPANCY | | | HAVING AN OCCUPANT LOAD OF 100 OR MORE ARE RELEASED BY | | | PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | | | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIREMENTS | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-21 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-09 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-26 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-21 |
Time |
06:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-24 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-24 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
|