Plan Review Details - Permit 21071007
| Plan Review Stops For Permit 21071007 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-21 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-21 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-08-03 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-08-03 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-21 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-21 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2021-07-21 14:15:47 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC R 301: | | | | | | 1. ON THE INSTALLATION SCHEDULE IT STATES THAT THE | | | SUBSTRATE IS CONCRETE/BLOCK. DOES THAT MEAN CONCRETE ON | | | THE TOP, BLOCK ON THE BOTTOM, OR CONCRETE BLOCK? | | | | | | PAGE 6, THE TRAPPED MOUNT IS CIRCLED. AT THE TOP POURED | | | CONCRETE IS REQUIRED, SPACING CAN BE 24" PER THE | | | DETAIL. THEREFORE IT APPEARS THAT THE ANCHOR SPACING | | | PROPOSED IS FOR THE SIDES. | | | | | | PAGE 8 BUILDOUT MOUNT IS CIRCLED, IT REFERS TO ANCHOR | | | CHARTS ON SHEETS 17 AND 15, THIS ALLOWS FOR FILLED | | | CONCRETE BLOCK SUBSTRATE, NOTHING ON PAGES 17 AND 18 | | | ARE CIRCLED. | | | | | | PAGE 16 ANCHOR SPACING FOR TRAPPED MOUNT IS CIRCLED. | | | SUBSTRATE IS REQUIRED TO BE POURED CONCRETE (NOT BLOCK, | | | NOT FILLED CELL BLOCK). | | | | | | PLEASE CORRELATE THE ANCHOR SCHEDULE, THE MARKUPS ON | | | THE PRODUCT APPROVAL, AND THE PROPOSED INSTALLATION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-19 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-19 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-27 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-27 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2021-07-27 11:47:22 | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLEASE SUBMIT A PLAN SHOWING THE SIZE OF THE WIRE AND | | | OVERCURRENT PROTECTION FOR THE ROLL UP SHUTTER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-22 |
Time |
19:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-22 |
Time |
19:51 |
Sent To |
|
|
| Notes |
| 2021-07-22 19:53:16 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLEASE SUBMIT AN ELECTRICAL PLAN FOR SHUTTER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-21 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-12 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-08-03 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-07-23 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-22 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-20 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
|