Plan Review Details - Permit 21070953
| Plan Review Stops For Permit 21070953 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-09 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-09 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2021-08-09 16:45:49 | 08/09/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-07-27 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-07-27 |
Time |
05:25 |
Sent To |
|
|
| Notes |
| 2021-07-27 06:08:25 | 1) SUBMIT MANUFACTURER'S SPECIFICATION SHEETSS FOR ALL | | | GAS APPLIANCES. GAS APPLIANCES SHALL BE LISTED AND | | | LABELED PER FBC-FUEL GAS SEC.301.3. | | | 2) THE REFERENCED TABLE ON THE PLANS FOR THE PE PIPE IS | | | FOR A 2 PSI SYSTEM YET THE PLANS SHOW A 12 INCH WATER | | | COLUMN. CLARIFY. | | | 3) SHOW THE DEVELOPED LENGTH OF THE SYSTEM FROM THE GAS | | | METER TO THE MOST REMOTE OUTLET ON THE SYSTEM. FBC-GAS | | | SEC.402.4. | | | 4) SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF THE GAS | | | APPLIANCES. THE DRYER MAY REQUIRE COMBUSTION AIR IF | | | LOCATED IN A ROOM WITH A DOOR. SUBMIT CALCULATIONS FOR | | | COMBUSTION AIR PER THE FBC-RES. SEC.G 2407.1 AND | | | G2439.4 (CLOTHES DRYERS). | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-09 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-05 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-27 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-23 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-09 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-09 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-07-27 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-07-27 |
Time |
06:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-07-27 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-07-27 |
Time |
06:08 |
Sent To |
|
|
| Notes |
|
|
|