Plan Review Details - Permit 21070890
| Plan Review Stops For Permit 21070890 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-03 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-03 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-09-24 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-09-24 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2021-09-24 18:33:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 107 PROVIDE A PLAN SHOWING LOCATIONS OF PROPOSED | | | GRATE REPLACEMENT. | | | | | | 2. A PERMIT APPLICATION WITH THE OWNER'S NOTARIZED | | | SIGNATURE IS REQUIRED FOR ALL PROJECTS OVER $2500. THE | | | APPLICATION SUBMITTED DOES NOT MEET THE REQUIRMENTS OF | | | THE REMOTE ONLINE NOTARY PER FLORIDA STATUTE FS117. A | | | SCAN OF A PAPER NOTARIZED DOCUMENT IS ACCEPTABLE, AS IS | | | AN APPLICATION THAT WAS NOTARIZED REMOTELY ONLINE IN | | | ACCORDANCE WITH FS117. | | | | | | 3. FBC 107, SHOP DRAWINGS ARE TO BE REVIEWED BY THE | | | ENGINEER (SHOP DRAWING REVIEW STAMP). | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-11-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-11-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-11-22 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-08-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-08-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-08-26 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2021-08-26 12:34:38 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATIONS OF WHERE THE REPLACEMENT | | | FRAMES ARE LOCATED WITHIN THE SITE. | | | | | | PLEASE PROVIDE A SITE PLAN AND THE SPECIFIC LOCATIONS | | | OF THE PROPOSED FRAMES. | | | | | | | | | 1A) THERE ARE NO INDICATIONS OF A LIFE SAFETY PLAN THAT | | | INDICATES WHAT MEASURES WILL BE IMPLEMENTED TO PROTECT | | | PEDESTRIAN/WORKERS FROM ACCESS AREAS | | | UNDERCONSTRUCTION/REPAIR. | | | | | | PLEASE PROVIDE A DETAILED LIFE SAFETY PLAN INDICATING | | | SAFETY MEASUSRES/FEATURES FOR TH PROPOSED REPLACEMENT | | | PROJECT. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-03 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-11-17 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-09-24 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-25 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-03 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-03 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-09-24 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-09-24 |
Time |
18:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-09-10 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-09-10 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |