Plan Review Details - Permit 21070703
Plan Review Stops For Permit 21070703
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-07-16 Cont ID  
Sent By cpuell Date 2021-07-16 Time 16:24 Rev Time 0.00
Received By cpuell Date 2021-07-16 Time 16:24 Sent To  
Notes
2021-07-16 16:24:44SOUTH BOULDING HAS THE ADDRESS OF 238 9TH ST # 2,
 UPDATED PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-14 Cont ID  
Sent By rmcdouga Date 2021-10-14 Time 11:18 Rev Time 0.00
Received By rmcdouga Date 2021-10-14 Time 10:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-30 Cont ID  
Sent By rmcdouga Date 2021-07-30 Time 16:31 Rev Time 0.00
Received By rmcdouga Date 2021-07-30 Time 13:48 Sent To  
Notes
2021-07-30 15:36:34PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE DEMOLITION PLANS SHOW THAT THERE ARE 4 EXISTING
 APARTMENTS EACH WITH A KITCHEN AND AND A BATHROOM. THE
 OCCUPANCY TYPE FOR THIS BUILDING IS R-2. BECAUSE THIS
 IS NOT A ONE/ TWO FAMILY DWELLING OR A TOWNHOUSE THE
 FBC RESIDENTIAL CODE DOES NOT APPLY. THE CODES THAT DO
 APPLY ARE THE 2020 FBC EXISTING BUILDING AND FBC
 BUILDING.
  
 2) THE PROPOSED FIRST FLOOR PLAN SHOWS ONE OF THE TWO
 UNITS WITH THE KITCHEN REMOVED AND BEING CONVERTED TO A
 GYM WITH A LAUNDRY ROOM AND A BEDROOM. PLEASE CLARIFY
 THE PURPOSE AND USE OF THIS AREA. FBC AMENDMENTS
 107.2.1
  
 3) THE APARTMENTS ARE REQUIRED TO BE SEPARATED FROM
 EACH OTHER AND COMMON AREAS BY FIRE RESISTIVE RATED
 WALL PARTIONS AND FLOOR CEILING ASSEMBLIES. INDICATE
 THE RATED WALLS AND CEILINGS ON THE PLANS. FBC 420
  
 4) PROVIDE DETAILS THAT SHOW THE GUARDS AT THE
 BALCONIES AND STAIRS COMPLY WITH FBC 1015 FOR HEIGHT
 AND OPENING LIMITATIONS.
  
 5) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE
 COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION ON
 THE SUBMITTED PLANS. ADDITIONAL PLAN REVIEW COMMENTS
 MAY BE GENERATED WHEN MORE INFORMATION IS PROVIDED.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-04-05 Cont ID  
Sent By fgiaquin Date 2022-04-05 Time 22:47 Rev Time 0.00
Received By fgiaquin Date 2022-04-05 Time 19:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2021-09-28 Cont ID  
Sent By jleahy Date 2021-09-28 Time 14:51 Rev Time 0.00
Received By jleahy Date 2021-09-28 Time 14:43 Sent To  
Notes
2021-09-28 14:51:31ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) BRANCH CIRCUITS FROM BOTTOM UNIT PANEL "A" NOT
 ALLOWED TO FEED CIRCUITS IN GYM, STORAGE, LAUNDRY,
 OUTSIDE LIGHTS ECT. ECT. 210.25 NEED A SEPARATE PANEL
 AND MAIN.
  
 210.25 BRANCH CIRCUITS IN BUILDINGS WITH MORE THAN ONE
 OCCUPANCY.
 (A) DWELLING UNIT BRANCH CIRCUITS. BRANCH CIRCUITS IN
 EACH DWELLING UNIT SHALL SUPPLY ONLY LOADS WITHIN THAT
 DWELLING UNIT
 OR LOADS ASSOCIATED ONLY WITH THAT DWELLING UNIT.
 (B) COMMON AREA BRANCH CIRCUITS. BRANCH CIRCUITS
 INSTALLED FOR THE PURPOSE OF LIGHTING, CENTRAL ALARM,
 SIGNAL, COMMUNICATIONS,
 OR OTHER PURPOSES FOR PUBLIC OR COMMON AREAS OF A
 TWOFAMILY DWELLING, A MULTIFAMILY DWELLING, OR A
 MULTI-OCCUPANCY
 BUILDING SHALL NOT BE SUPPLIED FROM EQUIPMENT THAT
 SUPPLIES AN INDIVIDUAL DWELLING UNIT OR TENANT SPACE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-24 Cont ID  
Sent By fgiaquin Date 2021-07-24 Time 12:52 Rev Time 0.00
Received By fgiaquin Date 2021-07-24 Time 11:48 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-11-15 Cont ID  
Sent By jleahy Date 2022-11-15 Time 10:11 Rev Time 0.00
Received By jleahy Date 2022-11-15 Time 10:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2021-09-17 Cont ID  
Sent By pleduc Date 2021-09-17 Time   Rev Time 0.00
Received By pleduc Date 2021-09-17 Time 10:51 Sent To  
Notes
2021-09-17 10:51:59APPLICANT CONFIRMED THIS IS A DUPLEX.
  
 NO LIFE SAFETY REVIEW REQUIRED BY FIRE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-08-05 Cont ID  
Sent By pleduc Date 2021-08-05 Time   Rev Time 0.00
Received By pleduc Date 2021-08-05 Time 12:39 Sent To  
Notes
2021-08-05 12:42:38THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) IT APPEARS THAT THE BUILDING IS A DUPLEX WITH ONE
 UNIT ON THE 1ST FLOOR AND ONE ON THE 2ND FLOOR.
  
 FOR CLARIFICATION PURPOSES, PLEASE INDICATE/VERIFY HOW
 MANY UNITS ARE WITHIN THIS BUILDING.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 4 Status P Date 2022-06-15 Cont ID  
Sent By ccole Date 2022-06-15 Time 16:50 Rev Time 0.00
Received By ccole Date 2022-06-15 Time 12:58 Sent To  
Notes
2022-06-15 16:51:18GAS SUB-PERMIT REQUIRED.

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2022-05-25 Cont ID  
Sent By ccole Date 2022-05-25 Time 17:26 Rev Time 0.00
Received By ccole Date 2022-05-25 Time 17:26 Sent To  
Notes
2022-05-25 17:28:553RD REVIEW FBC-2020 RES. GAS
 PERMIT- 21070703
 5/25/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. CORRECTED GAS PLANS WERE
 JOT SUBMITTED FOR REVIEW. PLEASE SUBMIT CORRECT PLANS
 IN COMPLAINCE WITH THE COMMENTS BELOW.
  
 1) THE GAS RISER IS INCOMPLETE. REFER TO FBC RES AND
 PROVIDE:
  
 A) TYPE AND SIZE OF RISER PIPES AT THE METER AND AT THE
 WATER HEATERS- SEC. G2413.1.
  
 B) LOCATIONS OF REGULATORS AND INLET AND OUTLET
 PRESSURES- SEC. G2421.1.
  
 C) TOTAL DEVELOPED LENGTH OF THE PIPING- SEC.
 G2413.4.1.
  
 D) ELECTRICAL BONDING OF PIPING THAT IS LIKELY TO
 BECOME ENERGIZED- SEC. G2411.1
  
 2) PROVIDE A PLAN VIEW SHOWING THE LOCATION OF THE
 WATER HEATERS AND REQUIRED CLEARANCE DISTANCES FROM
 GRADE, OVERHEAD CONSTRUCTION, AND OPENINGS AND AIR
 INTAKES INTO THE BUILDING- SEC.- G2427.8 & G2448.1 FBC
 RES.
  
 3) THE RISER AND OTHER PLANS SHALL INCLUDE THE
 SIGNATURE OF THE LICENSED CONTRACTOR OR QUALIFIER
 RESPONSIBLE FOR THE DESIGN- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-03-15 Cont ID  
Sent By ccole Date 2022-03-15 Time 15:49 Rev Time 0.00
Received By ccole Date 2022-03-15 Time 13:29 Sent To  
Notes
2022-03-15 15:53:431ST REVIEW FBC-2020 RES. GAS
 PERMIT- 21070703
 3/15/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GAS RISER IS INCOMPLETE. REFER TO FBC RES AND
 PROVIDE:
  
 A) TYPE AND SIZE OF RISER PIPES AT THE METER AND AT THE
 WATER HEATERS- SEC. G2413.1.
  
 B) LOCATIONS OF REGULATORS AND INLET AND OUTLET
 PRESSURES- SEC. G2421.1.
  
 C) TOTAL DEVELOPED LENGTH OF THE PIPING- SEC.
 G2413.4.1.
  
 D) ELECTRICAL BONDING OF PIPING THAT IS LIKELY TO
 BECOME ENERGIZED- SEC. G2411.1
  
 2) PROVIDE A PLAN VIEW SHOWING THE LOCATION OF THE
 WATER HEATERS AND REQUIRED CLEARANCE DISTANCES FROM
 GRADE, OVERHEAD CONSTRUCTION, AND OPENINGS AND AIR
 INTAKES INTO THE BUILDING- SEC.- G2427.8 & G2448.1 FBC
 RES.
  
 3) THE RISER AND OTHER PLANS SHALL INCLUDE THE
 SIGNATURE OF THE LICENSED CONTRACTOR OR QUALIFIER
 RESPONSIBLE FOR THE DESIGN- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-01-28 Cont ID  
Sent By ccole Date 2022-01-28 Time 12:50 Rev Time 0.00
Received By ccole Date 2022-01-28 Time 12:19 Sent To  
Notes
2022-01-28 12:50:341ST REVIEW FBC-2020 RES. GAS
 PERMIT- 21070703
 1/28/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW
 GAS-FIRED TANKLESS WATER HEATER AND SUBMIT
 MANUFACTURER?S SPECIFICATIONS- SEC. G2408.1 FBC RES.
  
 2) A.1: PROVIDE A COMPLETE GAS RISER DRAWING THAT
 INCLUDES ALL NEW AND EXISTING GAS PIPING AND APPLIANCES
 AT THE RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES.
 REFER TO FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL
 INDICATE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 3) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 REGULATORS MARKED UP TO SHOW MAKES AND MODEL
 SELECTIONS, INLET AND OUTLET PIPE SIZES AND PRESSURES-
 SECS. G2421.1 & G2421.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date   Cont ID  
Sent By   Date 2022-06-15 Time   Rev Time 0.00
Received By aoliver Date 2022-06-14 Time 07:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-05-27 Cont ID  
Sent By medwards Date 2022-05-27 Time 06:38 Rev Time 0.00
Received By medwards Date 2022-05-12 Time 08:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-04-05 Cont ID  
Sent By fgiaquin Date 2022-04-05 Time 22:49 Rev Time 0.00
Received By fgiaquin Date 2022-03-11 Time 08:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2022-01-28 Time   Rev Time 0.00
Received By aoliver Date 2022-01-12 Time 17:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-14 Cont ID  
Sent By rmcdouga Date 2021-10-14 Time 11:18 Rev Time 0.00
Received By rmcdouga Date 2021-09-16 Time 08:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-05 Cont ID  
Sent By lmarchan Date 2021-08-05 Time 13:23 Rev Time 0.00
Received By lmarchan Date 2021-07-19 Time 15:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2022-05-27 Cont ID  
Sent By medwards Date 2022-05-27 Time 06:36 Rev Time 0.00
Received By medwards Date 2022-05-27 Time 06:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2022-04-01 Cont ID  
Sent By medwards Date 2022-04-01 Time 11:06 Rev Time 0.00
Received By medwards Date 2022-04-01 Time 11:06 Sent To  
Notes
2022-04-01 11:07:01THE MECHANICAL EQUIPMENT SIZING CALCULATIONS STILL DO
 NOT REFLECT THE MECHANICAL DRAWING.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2022-01-24 Cont ID  
Sent By medwards Date 2022-01-24 Time 16:22 Rev Time 0.00
Received By medwards Date 2022-01-24 Time 15:15 Sent To  
Notes
2022-01-24 16:22:233RD REVIEW FBC-2020 MECHANICAL
 PERMIT-21070703
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS
 BUILDING. THE ENERGY CALCULATIONS SUBMITTED ARE FOR
 SINGLE FAMILY UNIT WITH 3 BEDROOMS AND A TOTAL
 CONDITIONED FLOOR AREA OF 2221. THE BUILDING IS A 2
 UNIT APARTMENT BUILDING WITH A HOUSE LAUNDRY AND GYM
 AREA. THESE ENERGY CALCULATIONS SHOW 1 60 GAL. WATER
 HEATER BUT THE LATEST DRAWING SHOWS A GAS TANKLESS
 WATER HEATER. THESE ENERGY CALCULATIONS ALSO INDICATE 2
 ZONES, BUT THERE ARE 3 HEATING SYSTEMS. FBC EC R403.7.1
  
 2) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 INDICATE ONLY 2 ZONES, BUT THERE ARE 3 MECHANICAL
 SYSTEMS: 1 FOR THE 1ST FLOOR APARTMENT, 1 FOR THE
 LAUNDRY ROOM, STORAGE AND GYM; AND 1 FOR THE 2ND FLOOR
 APARTMENT. PLEASE PROVIDE THE MECHANICAL EQUIPMENT
 SIZING CALCULATIONS TO REFLECT THIS. FBC EC R403.7.1
  
 3) WITH THE ADDITION OF THE NEW GAS WATER HEATER A GAS
 PERMIT WILL BE REQUIRED.
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-09-28 Cont ID  
Sent By medwards Date 2021-09-28 Time 13:22 Rev Time 0.00
Received By medwards Date 2021-09-28 Time 13:22 Sent To  
Notes
2021-09-28 14:10:592ND REVIEW FBC-2020 MECHANICAL
 PERMIT-21070703
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A.1 SHOWS A RATED WALL BETWEEN THE APARTMENT
 AND THE BUILDING COMMON AREA. THE MECHANICAL SYSTEM
 CANNOT BE SHARED BETWEEN THE DWELLING UNIT AND THE
 COMMON AREA AS THEY ARE 2 SEPARATE OCCUPANCIES. PLEASE
 SHOW THAT EACH SPACE HAS IT?S OWN MECHANICAL SYSTEM.
 FBC EC R403.1
  
 2) PLEASE PROVIDE NEW MECHANICAL EQUIPMENT SIZING
 CALCULATIONS FOR EACH APARTMENT AND THE COMMON AREA.
 FBC EC R403.7.1 AND FBC EC C403.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-07-29 Cont ID  
Sent By medwards Date 2021-07-29 Time 11:17 Rev Time 0.00
Received By medwards Date 2021-07-29 Time 11:17 Sent To  
Notes
2021-07-29 11:19:351ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21070703
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THIS IS 3 APARTMENTS WITH A COMMON GYM AND LAUNDRY
 AREA. THERE SHOULD BE TENANT SEPARATION AND EACH UNIT
 MUST HAVE ITS OWN MECHANICAL SYSTEM. PLEASE SUBMIT
 MECHANICAL EQUIPMENT SIZING CALCULATIONS AND MECHANICAL
 DRAWINGS SHOWING EACH UNIT HAVING IT?S OWN SYSTEM. THE
 EQUIPMENT SIZING CALCULATIONS AND THE MECHANICAL SYSTEM
 DESIGN MUST BE DIGITALLY SIGNED BY AN ENGINEER OR THE
 MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT TO INSTALL
 THE SYSTEMS FOR THIS PROJECT. F.S. 471.003(H), NEITHER
 SPACE CAN SHARE WITH THE OTHER. FBC M DEFINITIONS-
 DWELLING UNIT.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-06-15 Cont ID  
Sent By ccole Date 2022-06-15 Time 16:41 Rev Time 0.00
Received By ccole Date 2022-06-15 Time 12:58 Sent To  
Notes
2022-06-15 16:52:17PLUMBING SUB-PERMIT REQUIRED.

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-05-25 Cont ID  
Sent By ccole Date 2022-05-25 Time 17:29 Rev Time 0.00
Received By ccole Date 2022-05-25 Time 17:24 Sent To  
Notes
2022-05-25 17:32:163RD REVIEW FBC-2020 RES. PLUMBING.
 PERMIT- 21070703
 5/25/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. THE CORRECTED GAS PLAN
 SHOWING THE NEW WATER HEATERS WAS NOT SUBMITTED FOR
 REVIEW. PLEASE NOTE A PLUMBING SUB-PERMIT IS REQUIRED
 FOR INSTALLATION OF THE WATER SUPPLY PIPING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-03-15 Cont ID  
Sent By ccole Date 2022-03-15 Time 15:01 Rev Time 0.00
Received By ccole Date 2022-03-15 Time 15:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-01-28 Cont ID  
Sent By ccole Date 2022-01-28 Time 12:28 Rev Time 0.00
Received By ccole Date 2022-01-28 Time 12:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date   Cont ID  
Sent By   Date 2022-06-15 Time   Rev Time 0.00
Received By ccole Date 2022-06-15 Time 12:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status N Date 2022-05-27 Cont ID  
Sent By medwards Date 2022-05-27 Time 06:38 Rev Time 0.00
Received By medwards Date 2022-05-27 Time 06:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-04-05 Cont ID  
Sent By fgiaquin Date 2022-04-05 Time 22:48 Rev Time 0.00
Received By fgiaquin Date   Time   Sent To  
Notes
2022-04-05 22:48:31ELEC SIGNATURE OK

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-01-28 Cont ID  
Sent By ccole Date 2022-01-28 Time 12:34 Rev Time 0.00
Received By ccole Date 2022-01-28 Time 12:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-09-28 Cont ID  
Sent By medwards Date 2021-09-28 Time 14:12 Rev Time 0.00
Received By medwards Date 2021-09-28 Time 14:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-29 Cont ID  
Sent By medwards Date 2021-07-29 Time 11:20 Rev Time 0.00
Received By medwards Date 2021-07-29 Time 11:20 Sent To  
Notes
2021-07-29 11:22:54THE MECHANICAL EQUIPMENT SIZING CALCULATIONS MUST BE
 DIGITALLY SIGNE AND SEALED BY A LICENSED ENGINEER OR
 THE MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT TO
 INSTALL THE SYSTEMS FOR THIS PROJECT MAY PRINT THEN
 SIGN HIS NAME. F.S. 471.003(H)
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-01-14 Cont ID  
Sent By ckimmerl Date 2022-01-14 Time 11:48 Rev Time 0.00
Received By ckimmerl Date 2022-01-14 Time 11:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2021-09-27 Cont ID  
Sent By ckimmerl Date 2021-09-27 Time 16:37 Rev Time 0.00
Received By ckimmerl Date 2021-09-27 Time 16:31 Sent To  
Notes
2021-09-27 16:36:48- INCONSISTENCY BETWEEN SUBMITTED LANDSCAPE PLAN FOR
 PROPERTY AND GENERAL SITE PLAN FOR BUILDING #2. PLEASE
 PROVIDE A RECENT SURVEY TO CONFIRM THE SPACING BETWEEN
 THE PROPERTY LINE, THE SIDE LOT SETBACK, AND PROPOSED
 AC UNITS. MECHANICAL EQUIPMENT CANNOT ENCROACH MORE
 THAN 4 FT. INTO SETBACK.
  
 - A SEPARATE LANDSDCAPE PERMIT IS REQUESTED UNDER THE
 MAIN BUILDING RENOVATION PERMIT.
 - ANY ADDITIONAL PERMITS FOR THE RENOVATION/PROPERTY
 WILL BE SEPARATE THIS INCLUDES BUT IS NOT LIMITED TO:
 IRRIGATION, POOL. FENCE, LANDSCAPE, ETC.

Review Stop Z ZONING
Rev No 1 Status F Date 2021-08-05 Cont ID  
Sent By aaponte Date 2021-08-05 Time 11:28 Rev Time 0.00
Received By ckimmerl Date 2021-08-05 Time 11:26 Sent To  
Notes
2021-08-05 11:27:16- PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY,
 WHICH INCLUDES PROPERTY?S ADDRESS AND LEGAL DESCRIPTION
  
 - THE VALUE OF THE CONSTRUCTION ($200,000) EXCEEDS 50%
 OF BOTH THE STRUCTURE'S VALUE ($304,452) ACCORDING TO
 THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY.
  
2021-07-21 10:15:57NEW STAIRS SHOWN ON 002A