| Plan Review Stops For Permit 21070703 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-16 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-16 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2021-07-16 16:24:44 | SOUTH BOULDING HAS THE ADDRESS OF 238 9TH ST # 2, | | | UPDATED PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-10-14 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-10-14 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-30 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-30 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2021-07-30 15:36:34 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE DEMOLITION PLANS SHOW THAT THERE ARE 4 EXISTING | | | APARTMENTS EACH WITH A KITCHEN AND AND A BATHROOM. THE | | | OCCUPANCY TYPE FOR THIS BUILDING IS R-2. BECAUSE THIS | | | IS NOT A ONE/ TWO FAMILY DWELLING OR A TOWNHOUSE THE | | | FBC RESIDENTIAL CODE DOES NOT APPLY. THE CODES THAT DO | | | APPLY ARE THE 2020 FBC EXISTING BUILDING AND FBC | | | BUILDING. | | | | | | 2) THE PROPOSED FIRST FLOOR PLAN SHOWS ONE OF THE TWO | | | UNITS WITH THE KITCHEN REMOVED AND BEING CONVERTED TO A | | | GYM WITH A LAUNDRY ROOM AND A BEDROOM. PLEASE CLARIFY | | | THE PURPOSE AND USE OF THIS AREA. FBC AMENDMENTS | | | 107.2.1 | | | | | | 3) THE APARTMENTS ARE REQUIRED TO BE SEPARATED FROM | | | EACH OTHER AND COMMON AREAS BY FIRE RESISTIVE RATED | | | WALL PARTIONS AND FLOOR CEILING ASSEMBLIES. INDICATE | | | THE RATED WALLS AND CEILINGS ON THE PLANS. FBC 420 | | | | | | 4) PROVIDE DETAILS THAT SHOW THE GUARDS AT THE | | | BALCONIES AND STAIRS COMPLY WITH FBC 1015 FOR HEIGHT | | | AND OPENING LIMITATIONS. | | | | | | 5) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION ON | | | THE SUBMITTED PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | | MAY BE GENERATED WHEN MORE INFORMATION IS PROVIDED. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-04-05 |
Time |
22:47 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-04-05 |
Time |
19:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-09-28 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-28 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2021-09-28 14:51:31 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) BRANCH CIRCUITS FROM BOTTOM UNIT PANEL "A" NOT | | | ALLOWED TO FEED CIRCUITS IN GYM, STORAGE, LAUNDRY, | | | OUTSIDE LIGHTS ECT. ECT. 210.25 NEED A SEPARATE PANEL | | | AND MAIN. | | | | | | 210.25 BRANCH CIRCUITS IN BUILDINGS WITH MORE THAN ONE | | | OCCUPANCY. | | | (A) DWELLING UNIT BRANCH CIRCUITS. BRANCH CIRCUITS IN | | | EACH DWELLING UNIT SHALL SUPPLY ONLY LOADS WITHIN THAT | | | DWELLING UNIT | | | OR LOADS ASSOCIATED ONLY WITH THAT DWELLING UNIT. | | | (B) COMMON AREA BRANCH CIRCUITS. BRANCH CIRCUITS | | | INSTALLED FOR THE PURPOSE OF LIGHTING, CENTRAL ALARM, | | | SIGNAL, COMMUNICATIONS, | | | OR OTHER PURPOSES FOR PUBLIC OR COMMON AREAS OF A | | | TWOFAMILY DWELLING, A MULTIFAMILY DWELLING, OR A | | | MULTI-OCCUPANCY | | | BUILDING SHALL NOT BE SUPPLIED FROM EQUIPMENT THAT | | | SUPPLIES AN INDIVIDUAL DWELLING UNIT OR TENANT SPACE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-07-24 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-07-24 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-07-24 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-15 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-11-15 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-17 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2021-09-17 10:51:59 | APPLICANT CONFIRMED THIS IS A DUPLEX. | | | | | | NO LIFE SAFETY REVIEW REQUIRED BY FIRE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-08-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-08-05 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2021-08-05 12:42:38 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) IT APPEARS THAT THE BUILDING IS A DUPLEX WITH ONE | | | UNIT ON THE 1ST FLOOR AND ONE ON THE 2ND FLOOR. | | | | | | FOR CLARIFICATION PURPOSES, PLEASE INDICATE/VERIFY HOW | | | MANY UNITS ARE WITHIN THIS BUILDING. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2022-06-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-15 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-15 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2022-06-15 16:51:18 | GAS SUB-PERMIT REQUIRED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-25 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-25 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2022-05-25 17:28:55 | 3RD REVIEW FBC-2020 RES. GAS | | | PERMIT- 21070703 | | | 5/25/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. CORRECTED GAS PLANS WERE | | | JOT SUBMITTED FOR REVIEW. PLEASE SUBMIT CORRECT PLANS | | | IN COMPLAINCE WITH THE COMMENTS BELOW. | | | | | | 1) THE GAS RISER IS INCOMPLETE. REFER TO FBC RES AND | | | PROVIDE: | | | | | | A) TYPE AND SIZE OF RISER PIPES AT THE METER AND AT THE | | | WATER HEATERS- SEC. G2413.1. | | | | | | B) LOCATIONS OF REGULATORS AND INLET AND OUTLET | | | PRESSURES- SEC. G2421.1. | | | | | | C) TOTAL DEVELOPED LENGTH OF THE PIPING- SEC. | | | G2413.4.1. | | | | | | D) ELECTRICAL BONDING OF PIPING THAT IS LIKELY TO | | | BECOME ENERGIZED- SEC. G2411.1 | | | | | | 2) PROVIDE A PLAN VIEW SHOWING THE LOCATION OF THE | | | WATER HEATERS AND REQUIRED CLEARANCE DISTANCES FROM | | | GRADE, OVERHEAD CONSTRUCTION, AND OPENINGS AND AIR | | | INTAKES INTO THE BUILDING- SEC.- G2427.8 & G2448.1 FBC | | | RES. | | | | | | 3) THE RISER AND OTHER PLANS SHALL INCLUDE THE | | | SIGNATURE OF THE LICENSED CONTRACTOR OR QUALIFIER | | | RESPONSIBLE FOR THE DESIGN- SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-15 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-15 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2022-03-15 15:53:43 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 21070703 | | | 3/15/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GAS RISER IS INCOMPLETE. REFER TO FBC RES AND | | | PROVIDE: | | | | | | A) TYPE AND SIZE OF RISER PIPES AT THE METER AND AT THE | | | WATER HEATERS- SEC. G2413.1. | | | | | | B) LOCATIONS OF REGULATORS AND INLET AND OUTLET | | | PRESSURES- SEC. G2421.1. | | | | | | C) TOTAL DEVELOPED LENGTH OF THE PIPING- SEC. | | | G2413.4.1. | | | | | | D) ELECTRICAL BONDING OF PIPING THAT IS LIKELY TO | | | BECOME ENERGIZED- SEC. G2411.1 | | | | | | 2) PROVIDE A PLAN VIEW SHOWING THE LOCATION OF THE | | | WATER HEATERS AND REQUIRED CLEARANCE DISTANCES FROM | | | GRADE, OVERHEAD CONSTRUCTION, AND OPENINGS AND AIR | | | INTAKES INTO THE BUILDING- SEC.- G2427.8 & G2448.1 FBC | | | RES. | | | | | | 3) THE RISER AND OTHER PLANS SHALL INCLUDE THE | | | SIGNATURE OF THE LICENSED CONTRACTOR OR QUALIFIER | | | RESPONSIBLE FOR THE DESIGN- SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-28 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-28 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2022-01-28 12:50:34 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 21070703 | | | 1/28/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW | | | GAS-FIRED TANKLESS WATER HEATER AND SUBMIT | | | MANUFACTURER?S SPECIFICATIONS- SEC. G2408.1 FBC RES. | | | | | | 2) A.1: PROVIDE A COMPLETE GAS RISER DRAWING THAT | | | INCLUDES ALL NEW AND EXISTING GAS PIPING AND APPLIANCES | | | AT THE RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. | | | REFER TO FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL | | | INDICATE: | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | H) OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | 3) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | REGULATORS MARKED UP TO SHOW MAKES AND MODEL | | | SELECTIONS, INLET AND OUTLET PIPE SIZES AND PRESSURES- | | | SECS. G2421.1 & G2421.2 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-06-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-06-14 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-27 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-12 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-04-05 |
Time |
22:49 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-03-11 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-01-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-01-12 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-10-14 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-16 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-08-05 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-19 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-27 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-27 |
Time |
06:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-04-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-01 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-01 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2022-04-01 11:07:01 | THE MECHANICAL EQUIPMENT SIZING CALCULATIONS STILL DO | | | NOT REFLECT THE MECHANICAL DRAWING. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-24 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-24 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2022-01-24 16:22:23 | 3RD REVIEW FBC-2020 MECHANICAL | | | PERMIT-21070703 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS | | | BUILDING. THE ENERGY CALCULATIONS SUBMITTED ARE FOR | | | SINGLE FAMILY UNIT WITH 3 BEDROOMS AND A TOTAL | | | CONDITIONED FLOOR AREA OF 2221. THE BUILDING IS A 2 | | | UNIT APARTMENT BUILDING WITH A HOUSE LAUNDRY AND GYM | | | AREA. THESE ENERGY CALCULATIONS SHOW 1 60 GAL. WATER | | | HEATER BUT THE LATEST DRAWING SHOWS A GAS TANKLESS | | | WATER HEATER. THESE ENERGY CALCULATIONS ALSO INDICATE 2 | | | ZONES, BUT THERE ARE 3 HEATING SYSTEMS. FBC EC R403.7.1 | | | | | | 2) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | INDICATE ONLY 2 ZONES, BUT THERE ARE 3 MECHANICAL | | | SYSTEMS: 1 FOR THE 1ST FLOOR APARTMENT, 1 FOR THE | | | LAUNDRY ROOM, STORAGE AND GYM; AND 1 FOR THE 2ND FLOOR | | | APARTMENT. PLEASE PROVIDE THE MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS TO REFLECT THIS. FBC EC R403.7.1 | | | | | | 3) WITH THE ADDITION OF THE NEW GAS WATER HEATER A GAS | | | PERMIT WILL BE REQUIRED. | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-28 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-28 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2021-09-28 14:10:59 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21070703 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A.1 SHOWS A RATED WALL BETWEEN THE APARTMENT | | | AND THE BUILDING COMMON AREA. THE MECHANICAL SYSTEM | | | CANNOT BE SHARED BETWEEN THE DWELLING UNIT AND THE | | | COMMON AREA AS THEY ARE 2 SEPARATE OCCUPANCIES. PLEASE | | | SHOW THAT EACH SPACE HAS IT?S OWN MECHANICAL SYSTEM. | | | FBC EC R403.1 | | | | | | 2) PLEASE PROVIDE NEW MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR EACH APARTMENT AND THE COMMON AREA. | | | FBC EC R403.7.1 AND FBC EC C403.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-29 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-29 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2021-07-29 11:19:35 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21070703 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THIS IS 3 APARTMENTS WITH A COMMON GYM AND LAUNDRY | | | AREA. THERE SHOULD BE TENANT SEPARATION AND EACH UNIT | | | MUST HAVE ITS OWN MECHANICAL SYSTEM. PLEASE SUBMIT | | | MECHANICAL EQUIPMENT SIZING CALCULATIONS AND MECHANICAL | | | DRAWINGS SHOWING EACH UNIT HAVING IT?S OWN SYSTEM. THE | | | EQUIPMENT SIZING CALCULATIONS AND THE MECHANICAL SYSTEM | | | DESIGN MUST BE DIGITALLY SIGNED BY AN ENGINEER OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT TO INSTALL | | | THE SYSTEMS FOR THIS PROJECT. F.S. 471.003(H), NEITHER | | | SPACE CAN SHARE WITH THE OTHER. FBC M DEFINITIONS- | | | DWELLING UNIT. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-06-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-15 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-15 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2022-06-15 16:52:17 | PLUMBING SUB-PERMIT REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-25 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-25 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2022-05-25 17:32:16 | 3RD REVIEW FBC-2020 RES. PLUMBING. | | | PERMIT- 21070703 | | | 5/25/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. THE CORRECTED GAS PLAN | | | SHOWING THE NEW WATER HEATERS WAS NOT SUBMITTED FOR | | | REVIEW. PLEASE NOTE A PLUMBING SUB-PERMIT IS REQUIRED | | | FOR INSTALLATION OF THE WATER SUPPLY PIPING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-15 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-15 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-28 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-28 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-06-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-15 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-27 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-27 |
Time |
06:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-04-05 |
Time |
22:48 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-04-05 22:48:31 | ELEC SIGNATURE OK |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-28 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-28 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-28 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-28 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-29 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-29 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-07-29 11:22:54 | THE MECHANICAL EQUIPMENT SIZING CALCULATIONS MUST BE | | | DIGITALLY SIGNE AND SEALED BY A LICENSED ENGINEER OR | | | THE MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT TO | | | INSTALL THE SYSTEMS FOR THIS PROJECT MAY PRINT THEN | | | SIGN HIS NAME. F.S. 471.003(H) | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-01-14 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-01-14 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2021-09-27 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-09-27 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2021-09-27 16:36:48 | - INCONSISTENCY BETWEEN SUBMITTED LANDSCAPE PLAN FOR | | | PROPERTY AND GENERAL SITE PLAN FOR BUILDING #2. PLEASE | | | PROVIDE A RECENT SURVEY TO CONFIRM THE SPACING BETWEEN | | | THE PROPERTY LINE, THE SIDE LOT SETBACK, AND PROPOSED | | | AC UNITS. MECHANICAL EQUIPMENT CANNOT ENCROACH MORE | | | THAN 4 FT. INTO SETBACK. | | | | | | - A SEPARATE LANDSDCAPE PERMIT IS REQUESTED UNDER THE | | | MAIN BUILDING RENOVATION PERMIT. | | | - ANY ADDITIONAL PERMITS FOR THE RENOVATION/PROPERTY | | | WILL BE SEPARATE THIS INCLUDES BUT IS NOT LIMITED TO: | | | IRRIGATION, POOL. FENCE, LANDSCAPE, ETC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-08-05 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-08-05 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2021-08-05 11:27:16 | - PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, | | | WHICH INCLUDES PROPERTY?S ADDRESS AND LEGAL DESCRIPTION | | | | | | - THE VALUE OF THE CONSTRUCTION ($200,000) EXCEEDS 50% | | | OF BOTH THE STRUCTURE'S VALUE ($304,452) ACCORDING TO | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | | PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | | TO BRING THE SITE INTO CONFORMITY. | | | | | 2021-07-21 10:15:57 | NEW STAIRS SHOWN ON 002A |
|
|