| Plan Review Stops For Permit 21070679 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-14 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-14 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2021-07-14 10:23:30 | 7201 GEORGIA AVE ASSIGNED TO THIS BUILDING. |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
2021-07-19 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2021-07-19 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2021-07-19 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-27 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-27 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-12 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-12 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-10-12 10:59:48 | NEW COMMERCIAL BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) STORAGE ROOM ENTRY FROM THE INTERIOR OF THE BUILDING | | | - AN ACCESSIBLE ENTRY SHOULD BE PROVIDED PER FBC | | | A206.2.4 SPACES AND ELEMENTS. | | | AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE | | | BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE | | | SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY | | | WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION PATH | | | UNLESS EXEMPTED BY 206.2.3 EXCEPTIONS 1 THROUGH 7. | | | | | | 2) DRAWING C1.0 SHOWS 228 PARKING SPACES - 7 ACCESSIBLE | | | PARKING SPACES ARE REQUIRED PER FBC A TABLE 208.2 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-23 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-19 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2021-08-23 15:19:36 | NEW COMMERCIAL BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) DRAWING S3.1.K SHOWS WIND DESIGN 170MPH FOR RISK | | | CATEGORY III - RISK CATEGORY III REQUIRES A WIND SPEED | | | OF 180MPH - FBC WPB SECTION 120 | | | 2) DRAWING A5.0.3 SHOWS ROOF SHEATHING 5/8 PLYWOOD - | | | DRAWING A2.0.3 SHOWS ROOF SHEATHING 3/4 PLYWOOD - | | | DRAWINGS NEED TO MATCH. | | | 3) PLEASE PROVIDE A WALL FINISH DETAIL FOR THE SERVICE | | | SINK AREA TO COMPLY WITH FBC 1210.2.2 (DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE) | | | 4) ROOF TILE PRODUCT APPROVAL PROVIDED - PLEASE CIRCLE | | | THE ROOFING TILE ATTACHMENT TYPE TO BE USED ON THE | | | PRODUCT APPROVAL (ATTACHMENT TYPE WILL NEED TO MEET OR | | | EXCEED THE REQUIRED PRESSURES). IF USING ADHESIVE | | | PLEASE PROVIDE THE ADHESIVE PRODUCT APPROVAL. | | | 5) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR MAXIMUM | | | DIMENSION FROM THE FINISHED FLOOR TO THE BOTTOM OF THE | | | "REFLECTIVE SURFACE" PER FBC A603.3 | | | 6) STORAGE ROOM ENTRY FROM THE INTERIOR OF THE BUILDING | | | - AN ACCESSIBLE ENTRY SHOULD BE PROVIDED PER FBC | | | A206.2.4 SPACES AND ELEMENTS. | | | AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE | | | BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE | | | SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY | | | WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION PATH | | | UNLESS EXEMPTED BY 206.2.3 EXCEPTIONS 1 THROUGH 7. | | | 7) CORRIDOR 128 SHOWS DOORS THAT MAY BE BLOCKING THE | | | EGRESS - 1005.7.1DOORS. | | | DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED | | | WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY | | | POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE | | | THAN ONE-HALF. | | | 8) PLEASE SHOW THE FLAT DECK ROOF SLOPE TO COMPLY WITH | | | FBC 1507.13.1 | | | 9) PLEASE SHOW THE ATTIC ACCESS TO COMPLY WITH FBC | | | 1209.2 | | | 10) DRAWING C1.0 SHOWS 228 PARKING SPACES - 7 | | | ACCESSIBLE PARKING SPACES ARE REQUIRED PER FBC A TABLE | | | 208.2 | | | 11) CIVIL PLANS SHOW PROPERTY IN AN "X" AND "AE 14.8" - | | | PLEASE CLEARLY SHOW THE FLOOD ZONE DELINEATION LINES - | | | ARE ANY OF THE BUILDINGS IN THE "AE 14.8" FLOOD ZONE? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-15 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-15 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-19 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-19 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2021-08-19 16:13:57 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E2.1.1 | | | | | | 1) LOUNGE NEED TO IDENTIFY OUTLETS THAT WILL BE GFCI | | | PROTECTED PER 210.8(B) | | | | | | 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | PERSONNEL. | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | PERSONNEL SHALL BE PROVIDED AS REQUIRED IN 210.8(A) | | | THROUGH (E). THE | | | GROUND-FAULT CIRCUIT INTERRUPTER SHALL BE INSTALLED IN | | | A READILY ACCESSIBLE LOCATION. | | | | | | (B) OTHER THAN DWELLING UNITS. ALL SINGLE-PHASE | | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 | | | AMPERES OR LESS AND THREEPHASE | | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 | | | AMPERES OR LESS INSTALLED IN THE FOLLOWING LOCATIONS | | | SHALL | | | HAVE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | PERSONNEL. (5) SINKS ? WHERE RECEPTACLES ARE INSTALLED | | | WITHIN 1.8 M | | | (6 FT) FROM THE TOP INSIDE EDGE OF THE BOWL OF THE SINK | | | | | | 2) CONFERENCE ROOM 100, ? AND BOARD ROOM WALL AND FLOOR | | | OUTLETS TO MEET THE REQUIREMENTS OF 210.71 | | | 210.71 MEETING ROOMS. | | | (A) GENERAL. EACH MEETING ROOM OF NOT MORE THAN 93 M2 | | | (1000 FT2) IN OTHER THAN DWELLING UNITS SHALL HAVE | | | OUTLETS FOR | | | NONLOCKING-TYPE, 125-VOLT, 15- OR 20-AMPERE | | | RECEPTACLES. THE OUTLETS SHALL BE INSTALLED IN | | | ACCORDANCE WITH 210.71(B)(1)(2) | | | | | | (1) RECEPTACLE OUTLETS IN FIXED WALLS. RECEPTACLE | | | OUTLETS SHALL | | | BE INSTALLED IN ACCORDANCE WITH 210.52(A)(1) THROUGH | | | (A)(4). | | | | | | (2) FLOOR RECEPTACLE OUTLETS. A MEETING ROOM THAT IS AT | | | LEAST | | | 3.7 M (12 FT) WIDE AND THAT HAS A FLOOR AREA OF AT | | | LEAST 20 M2 | | | (215 FT2) SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET | | | LOCATED IN THE | | | FLOOR AT A DISTANCE NOT LESS THAN 1.8 M (6 FT) FROM ANY | | | FIXED WALL | | | FOR EACH 20 M2 (215 FT2) OR MAJOR PORTION OF FLOOR | | | SPACE | | | | | | 3) PLEASE IDENTIFY THE OUTLETS THAT WILL BE TAMPER | | | RESISTANT PER 406.12(B)(5) | | | | | | 406.12 TAMPER-RESISTANT RECEPTACLES. ALL 15- AND | | | 20-AMPERE, 125- AND 250-VOLT NONLOCKING-TYPE | | | RECEPTACLES IN THE AREAS | | | SPECIFIED IN 406.12(1) THROUGH (7) SHALL BE LISTED | | | TAMPERRESISTANT RECEPTACLES. | | | (1) DWELLING UNITS IN ALL AREAS SPECIFIED IN 210.52 AND | | | 550.13 | | | (2) GUEST ROOMS AND GUEST SUITES OF HOTELS AND MOTELS | | | (3) CHILD CARE FACILITIES | | | (4) PRESCHOOLS AND ELEMENTARY EDUCATION FACILITIES | | | (5) BUSINESS OFFICES, CORRIDORS, WAITING ROOMS AND THE | | | LIKE IN | | | CLINICS, MEDICAL AND DENTAL OFFICES AND OUTPATIENT | | | FACILITIES | | | (6) SUBSET OF ASSEMBLY OCCUPANCIES DESCRIBED IN 518.2 | | | TO | | | INCLUDE PLACES OF WAITING TRANSPORTATION, GYMNASIUMS, | | | SKATING RINKS, AND AUDITORIUMS | | | (7) DORMITORIE | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-10-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-10-05 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-08-04 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-08-04 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-08-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-08-04 13:49:35 | CURRENTLY UNDER REVIEW AS FORMAL ENGINEERING SUBMITTAL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-09-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-22 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-23 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-27 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-22 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-20 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-21 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-09 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-03 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-22 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2021-10-29 15:42:01 | RECEIPT MU-2021-0051614 - $37,321.91 PAID | | 2021-10-22 09:37:00 | 10/22/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-23 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-23 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2021-08-23 15:43:24 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-04 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-04 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-19 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-19 |
Time |
06:47 |
Sent To |
|
|
| Notes |
| 2021-08-19 07:44:32 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21070679 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M6.0.1: PLEASE PROVIDE THE OUTDOOR AIR | | | CALCULATIONS FOR EACH USE OF SPACE ACCORDING TO FBC | | | 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 2) SHEET M1.1.1: PLEASE IDENTIFY THE RTU FOR EACH DUCT | | | SYSTEM ON THIS SHEET (EXAMPLE, THE MULTIPURPOSE AREA IS | | | SERVED BY WHICH AHU? FBC 107.2.1 | | | | | | 3) SHEET M1.1.1: IT APPEARS THAT THE RETURN GRILLS FOR | | | THE OFFICES AT THE SOUTH SIDE OF THE BUILDING HAVE THE | | | SUPPLY SYMBOL, PLEASE CORRECT. FBC 107.2.1 | | | | | | 4) SHEET M1.1.1: NOTE 1 SENDS ME TO THE ELEVATION SHEET | | | FOR THE LOCATION OF THE FRESH AIR LOUVER FOR AHU-1. THE | | | ELEVATION SHEET DOES NOT SHOW THIS LOUVER. PLEASE SHOW | | | THE LOCATION OF THIS LOUVER. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-19 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-19 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2021-10-19 18:53:51 | 10/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-07 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-07 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-25 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2021-09-07 08:39:25 | 09/07/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET A9.0.1; | | | | | | A. ON DETAIL 9, WOULD YOU PLEASE SHOW THE CLEAR FLOOR | | | SPACE UNDER THE DRINKING FOUNTAIN OF 27 INCHES OF KNEE | | | CLEARANCE PER THE 2020 FBC SEC. 306.3 KNEE CLEARANCE. | | | | | | B. WOULD YOU PLEASE ADD THE MIRROR'S REFLECTIVE PART TO | | | THE OF 40 INCHES TO THE REFLECTIVE SIDE PER THE 2020 | | | FBC ACC SEC. 603.3. | | | | | | C. THE TOILET GRAB BAR SAYS 6 INCHES FROM THE WALL, | | | WHICH IS NOT AN ACTUAL NUMBER AS THE TOILET IS 16 | | | INCHES TO 18 INCHES TO THE CENTER, AND THAT NUMBER MAY | | | CONFUSE THE INSTALLER. WOULD YOU PLEASE CORRECT PER THE | | | WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS? | | | | | | D. WOULD YOU, PLEASE SHOW THE FLUSH CONTROL TO BE 36 | | | INCHES MAXIMUM ABOVE THE FINISH FLOOR PER THE 2020 FBC | | | ACC SEC. 604.9.5. | | | | | | E. ON DETAIL A, WOULD YOU PLEASE PROVIDE THE DIMENSION | | | FOR THE CLEAR FLOOR SPACE FOR THE WATER CLOSET AND LAV | | | PER THE 2020 FBC ACCESSIBILITY CODE. | | | | | | F. DETAIL 3 AND 7 SHOW THE FLUSH CONTROL, NOT THE OPEN | | | SPACE PER THE 2020 FBC SEC. 604.6 FLUSH CONTROLS. | | | | | | 2. ON SHEET A9.0.2; | | | | | | A. ON DETAIL 1, WOULD YOU PLEASE PROVIDE THE DIMENSION | | | FOR THE CLEAR FLOOR SPACE FOR THE WATER CLOSET AND LAV | | | PER THE 2020 FBC ACCESSIBILITY CODE. | | | | | | B. ON THAT SAME DETAIL, WOULD YOU PLEASE PROVIDE THE | | | CLEAR FLOOR SPACE AND DIMENSION FOR THE LAV IN THE OPEN | | | AREA OF 30 INCHES X 48 INCHES PER THE 2020 FBC SEC. ACC | | | 305.3. | | | | | | C. ON DETAIL 2, THE LAV ACCESSIBLE ON THE OPEN AREA, | | | WOULD YOU PLEASE SHOW THE MIRROR'S REFLECTIVE PART TO | | | THE OF 40 INCHES TO THE REFLECTIVE SIDE PER THE 2020 | | | FBC ACC SEC. 603.3. | | | | | | D. ON DETAIL 6, IT HAS THE HANDLE ON THE OPEN SIDE PER | | | THE 2020 FBC ACC SEC. 604.9.5. | | | | | | E. THERE IS A DRINKING FOUNTAIN AND NO DETAIL FOR | | | ACCESSIBILITY WITH ITS DEMISSION AND THE HEIGHT EITHER. | | | WOULD YOU PLEASE PROVIDE PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 3. ON SHEET A9.0.2; | | | | | | A. ON DETAIL 1, WOULD YOU PLEASE PROVIDE THE DIMENSION | | | FOR THE CLEAR FLOOR SPACE FOR THE WATER CLOSET AND LAVS | | | AND URINAL PER THE 2020 FBC ACCESSIBILITY CODE. | | | | | | B. ON DETAIL 5, THE REFLECTIVE PART OF THE MIRROR NEEDS | | | TO BE 40 INCHES TO THE REFLECTIVE SIDE PER THE 2020 FBC | | | ACC SEC. 603.3. | | | | | | C. ON DETAIL 6, IT HAS THE HANDLE ON THE OPEN SIDE PER | | | THE 2020 FBC ACC SEC. 604.9.5. | | | | | | D. ON THAT SAME DETAIL, WOULD YOU PLEASE PROVIDE THE | | | CLEAR FLOOR SPACE AND DIMENSION FOR THE LAV IN THE OPEN | | | AREA OF 30 INCHES X 48 INCHES PER THE 2020 FBC SEC. ACC | | | 305.3. | | | | | | E. WOULD YOU PLEASE SHOW THE DIMENSION FOR THE URINAL | | | OF A MINIMUM OF 30 INCHES PER THE 2020 FBC SEC. P | | | 405.3.1. | | | | | | 4. ON SHEET P6.0.1; | | | | | | A. ICEMAKER AND COFFEE MAKER SHALL BE EQUIPPED WITH AN | | | IN-LINE VACUUM BREAKER THAT COMPLIES WITH ASSE 1024 PER | | | THE 2020 FBC SEC. 608.13.10. | | | | | | B. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL | | | SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE | | | 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P | | | 310.3. WOULD YOU PLEASE MAKE A NOTE ON THIS SHEET? | | | | | | 5. ON SHEET P7.0.2; | | | | | | A. ON THE ROOF, THERE IS A HOSE BIBB THAT REQUIRES A | | | SHUT-OFF VALVE PER THE 2020 606.2 (2) LOCATION OF | | | SHUTOFF VALVES. | | | | | | B. THE RECIRCULATING MANIFOLD TO THE HOT WATER LINES | | | SHALL BE SUPPLIED TO THE SOURCE; PLEASE REFER TO THE | | | 2020 FBC ENERGY CODE TABLE C404.5.1. MAXIMUM ALLOWABLE | | | PIPE LENGTH METHOD. | | | | | | C. HOT WATER LINES ARE LOOPED FOR THE RECIRCULATING | | | SYSTEM, AND IT IS NOT IN A CONTINUOUS LOOP. THERE IS A | | | REQUIREMENT IN THE FLORIDA ENERGY CODE SEC. C404.6.1. | | | THERE IS A TABLE THAT LIMITS THE BETWEEN THE SOURCE AND | | | THE OUTLET. PLEASE REFER TO TABLE 405.5.1 FOR THE | | | MAXIMUM ALLOWABLE PIPE LENGTH METHOD AND SIZE | | | ACCORDANTLY. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, DESCRIBING THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-23 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-23 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2021-08-23 15:44:11 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-27 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-27 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-23 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-23 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2021-08-23 16:05:31 | SIGNATURE REVIEW | | | | | | CIVIL AND LANDSCAPE DRAWINGS NEED TO BE SIGNED AND | | | SEALED BY THE DESIGNER FBC WPB 107.1 | | | | | | FYI - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO | | | BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR - | | | IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | | | | MECHANICAL SHEETS APPROVED ME | | 2021-08-19 07:45:07 | MECHANICAL SHEETS APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-10-05 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-10-05 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2021-10-05 08:37:47 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 10.01.2021 | | | PERMIT NO.: 21070675 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW IS LIMITED TO THE SFPGA OFFICE BUILDING | | | ONLY AND HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. SEPARATE PERMITS REQUIRED FOR: | | | | | | 1.1. LANDSCAPING | | | 1.2. FENCING/GATES | | | 1.3. SITE/PRIVACY WALLS | | | 1.4. SITE LIGHTING | | | 1.5. IRRIGATION | | | 1.6. GENERATOR | | | 1.7. SIGNAGE | | | 1.8. PARING LOT / STRIPING / HARDSCAPE | | | 1.9. SITE FIXTURES (I.E. BIKE RACKS, ETC.) | | | | | | 2. THE WPB GOLF PARK DEVELOPMENT SHALL BE SUBJECT TO | | | ALL DEVELOPMENT ORDER CONDITIONS, AS OUTLINED IN FORMAL | | | SITE PLAN REVIEW (FSPR) CASE NO. 21-02, AND AS MAY BE | | | AMENDED. ALL CONDITIONS OF APPROVAL IMPOSED BY FSPR | | | CASE NO. 21-02, AS AMENDED, SHALL BE ADDRESSED WITHIN | | | THE APPROPRIATE SPECIFIED TIMEFRAMES. | | | | | | 3. A REVISION TO THE BUILDING AND LANDSCAPE PERMITS | | | SHALL BE SUBMITTED AND APPROVED TO REVISE THE PLANS AND | | | ACCURATELY REFLECT THE FOLLOWING: | | | | | | 3.1 LOCATION OF ALL MECHANICAL EQUIPMENT | | | 3.2 DETAIL ON THE MARKING FOR COMPACT PARKING SPACES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-25 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-09-25 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-09-25 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2021-09-25 11:48:11 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 09.03.2021 | | | PERMIT NO.: 21070679 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - THE SITE PLAN SUBMITTED DOES NOT | | | MATCH THE SITE PLAN THAT WAS APPROVED DURING THE FORMAL | | | SITE PLAN REVIEW PROCESS; A SIGNIFICANT AMOUNT OF | | | INFORMATION IS MISSING FROM THE SUBMITTED PLAN, ETC. | | | PLEASE INCLUDE THE SITE PLAN, DETAILS, ETC. THAT WAS | | | PREPARED BY URBAN DESIGN STUDIOS AND APPROVED AS PART | | | OF FSPR CASE NO. 21-02. IF MODIFICATIONS TO THE | | | APPROVED PLAN ARE NECESSARY, PLEASE INDICATE THE SCOPE | | | OF THE MODIFICATIONS TO DETERMINE IF AN AMENDMENT IS | | | REQUIRED. | | | | | | 2. [ SATISFIED ] - LANDSCAPE PLANS SHALL BE REMOVED | | | FROM THE BUILDING PERMIT SUBMITTAL AND SHALL BE | | | SUBMITTED AS A SEPARATE LANDSCAPE PERMIT. | | | | | | 3. [ SATISFIED ] - THE PARKING STRIPING DETAIL ON SHEET | | | C1.0 DOES NOT COMPLY WITH THE CITY?S STANDARD DETAIL. | | | PLEASE CONTACT ME FOR THE APPROPRIATE DETAIL (IF | | | NEEDED). | | | | | | 4. [ NOT SATISFIED ] - A DETAIL SHALL BE PROVIDED | | | INDICATING HOW THE COMPACT PARKING SPACES WILL BE | | | MARKED. | | | | | | 4.1 [ NEW COMMENT ] - THE RESPONSE TO COMMENTS | | | INDICATES THAT NO DETAIL IS BEING PROVIDED FOR THE | | | COMPACT SPACES AS NO COMPACT SPACES ARE PROPOSED. | | | HOWEVER, ACCORDING TO THE APPROVED SITE PLAN, THERE ARE | | | AT LEAST 16 COMPACT SPACES PROPOSED. AS SUCH, A DETAIL | | | SHOWING HOW THE SPACES WILL BE MARKED SHALL BE | | | PROVIDED. | | | | | | 5. [ SATISFIED ] - SEPARATE PERMITS REQUIRED FOR: | | | 5.1. LANDSCAPING | | | 5.2. FENCING/GATES | | | 5.3. SITE/PRIVACY WALLS | | | 5.4. SITE LIGHTING | | | 5.5. IRRIGATION | | | 5.6. GENERATOR | | | 5.7. SIGNAGE | | | 5.8. PARING LOT / STRIPING / HARDSCAPE | | | 5.9. SITE FIXTURES (I.E. BIKE RACKS, ETC.) | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-09-03 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-09-03 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2021-09-03 16:51:19 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 09.03.2021 | | | PERMIT NO.: 21070679 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE SITE PLAN SUBMITTED DOES NOT MATCH THE SITE PLAN | | | THAT WAS APPROVED DURING THE FORMAL SITE PLAN REVIEW | | | PROCESS; A SIGNIFICANT AMOUNT OF INFORMATION IS MISSING | | | FROM THE SUBMITTED PLAN, ETC. PLEASE INCLUDE THE SITE | | | PLAN, DETAILS, ETC. THAT WAS PREPARED BY URBAN DESIGN | | | STUDIOS AND APPROVED AS PART OF FSPR CASE NO. 21-02. IF | | | MODIFICATIONS TO THE APPROVED PLAN ARE NECESSARY, | | | PLEASE INDICATE THE SCOPE OF THE MODIFICATIONS TO | | | DETERMINE IF AN AMENDMENT IS REQUIRED. | | | | | | 2. LANDSCAPE PLANS SHALL BE REMOVED FROM THE BUILDING | | | PERMIT SUBMITTAL AND SHALL BE SUBMITTED AS A SEPARATE | | | LANDSCAPE PERMIT. | | | | | | 3. THE PARKING STRIPING DETAIL ON SHEET C1.0 DOES NOT | | | COMPLY WITH THE CITY?S STANDARD DETAIL. PLEASE CONTACT | | | ME FOR THE APPROPRIATE DETAIL (IF NEEDED). | | | | | | 4. A DETAIL SHALL BE PROVIDED INDICATING HOW THE | | | COMPACT PARKING SPACES WILL BE MARKED. | | | | | | 5. SEPARATE PERMITS REQUIRED FOR: | | | 5.1. LANDSCAPING | | | 5.2. FENCING/GATES | | | 5.3. SITE/PRIVACY WALLS | | | 5.4. SITE LIGHTING | | | 5.5. IRRIGATION | | | 5.6. GENERATOR | | | 5.7. SIGNAGE | | | 5.8. PARING LOT / STRIPING / HARDSCAPE | | | 5.9. SITE FIXTURES (I.E. BIKE RACKS, ETC.) | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|