| Plan Review Stops For Permit 21070505 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-13 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-13 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2021-08-28 08:41:43 | T.LARGE ENTERED NAME BY MISTAKE. | | 2021-07-13 13:16:03 | ADDRESS CORRECT, HOWEVER ABOVE THE MAIN ENTRANCE THE | | | ADDRESS OF 460 SOUTH ROSEMARY AVE SUITE 170E PLEASE | | | REMOVE THE E FROM ABOVE THE DOOR. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-22 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-13 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-13 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2021-10-13 07:41:41 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-02 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-01 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2021-09-02 08:35:34 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-06 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-06 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-22 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-22 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2021-11-22 15:09:50 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC RESIDENTIAL WITH WPB | | | CHAPTER 1 AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE EXTERIOR WALL FRAMING DETAILS - | | | SHOW FRAMING DESIGNATION, ON CENTER SPACING, ATTACHMENT | | | TYPE AND ON CENTER SPACING OF THE ATTACHMENTS ETC.- FBC | | | WPB 107.2.4 | | | | | | DEFERRED SUBMITTALS WILL NEED TO BE LISTED ON THE | | | DRAWINGS - FBC WPB 107.3.4.1 DEFERRED SUBMITTALS. FOR | | | THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-13 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-12 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2021-10-12 17:00:18 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC RESIDENTIAL WITH WPB | | | CHAPTER 1 AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE EXTERIOR WALL FRAMING DETAILS - | | | SHOW FRAMING DESIGNATION, ON CENTER SPACING, ATTACHMENT | | | TYPE AND ON CENTER SPACING OF THE ATTACHMENTS ETC.- FBC | | | WPB 107.2.4 | | | | | | 2) PLEASE SHOW THE EXTERIOR CLADDING DETAILS - | | | ATTACHMENT TYPE AND ON CENTER SPACING OF THE | | | ATTACHMENTS OR PROVIDE A PRODUCT APPROVAL FOR THE | | | EXTERIOR CLADDING. FBC 1405.11.1 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-02 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-01 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2021-09-02 08:30:34 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC RESIDENTIAL WITH WPB | | | CHAPTER 1 AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) PRODUCT APPROVALS THAT ARE | | | LISTED ON THE DRAWINGS. | | | 2) EXTERIOR WALL (EWS02) - PLEASE PROVIDE EFIS | | | ATTACHMENT DETAILS - PLEASE SHOW THE STRUCTURAL BACKING | | | FOR THE EFIS IF REQUIRED FBC 1408.3 STRUCTURAL DESIGN. | | | THE UNDERLYING STRUCTURAL FRAMING AND SUBSTRATE SHALL | | | BE DESIGNED AND CONSTRUCTED TO RESIST LOADS AS REQUIRED | | | BY CHAPTER 16. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-12 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-12 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-25 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-25 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2021-08-25 16:25:50 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-102 | | | | | | GFCI PROTECTION OF KITCHEN OUTLETS PER 210.8(B)(2) | | | | | | 210.8(B) OTHER THAN DWELLING UNITS. ALL SINGLE-PHASE | | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 | | | AMPERES OR LESS AND THREEPHASE | | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 | | | AMPERES OR LESS INSTALLED IN THE FOLLOWING LOCATIONS | | | SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION | | | FOR PERSONNEL. | | | | | | PAGE E-103 | | | | | | FAULT CURRENT CALCULATION REQUIRED FOR SERVICE AND | | | PANELS PER 110.9, 110.10 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-13 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-21 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2021-07-26 11:02:16 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) LIFE SAFETY SHEET - THE OCCUPANCY LOAD TOTAL FOR | | | DINING INDICATES 43. OUTSIDE SEATING SHALL NOT NE | | | INCLUDED IN THE OCCUPANCY TOTAL. | | | | | | 630/15= 42 | | | | | | PLEASE CORRECT. | | | | | | | | | 1A) LIFE SAFETY SHEET - THE OCCUPANCY LOAD COUNT OF 42 | | | APPEARS TO BE TOO LARGE FOR THIS AREA. THERE ARE | | | APPROX. 16 CHAIRS AND 6 BAR STOOLS INDICATED = 22. HOW | | | WOULD 20 MORE CHAIRS FIT? | | | | | | PLEASE PROVIDE DIMENSIONS OF HOW THE 630SQ FT IS | | | CALCULATED. | | | | | | | | | 1B) AS THIS IS A PROPOSED DONUT SHOP, IT WOULD APPEAR | | | THAT WALKIN SERVICE AND STANDING ROOM IS REQUIRED. | | | | | | THAT AREA OCCUPANCY LOAD WOULD BE CLACULATED AT 7SQ | | | FT/PERSON, NOT 15 FOR THE SEATING AREA. | | | | | | PLEAE EVIEW AND INDICATED DESIGNATED AREA AND CORRECT. | | | | | | | | | | | | 2) LIFE SAFETY SHEET - THE BAR COUNT INDICATES 2, | | | | | | THERE ARE 6 BAR STOOLS INDICATED. | | | | | | PLEASE CORRECT OR EXPLAIN. | | | | | | | | | | | | 3) LIFE SAFETY SHEET - THERE IS AN INDICATION UNDER | | | GENERAL NOTES #6 & 15; SEE FIRE PROTECTION DRAWINGS FOR | | | SPRINKLER LAYOUT. | | | | | | THIS OCCUPNACY HAS AN EXISTING SPRINKLER PROTECTION | | | WITH ODIFICATION BEING REQUIRED. | | | | | | ANY AND ALL WORK, INCLUDING DEMO, ON THE FIRE SPRINKLER | | | SYSTEM SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 4) THERE ARE INDICATIONS OF HOOD INSTALLATION. | | | | | | ANY AND ALL WORK ON THE HOOD SYSTEM SHALL BE DONE UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 5) ELECTRICAL - THERE ARE INDICATIONS OF FIRE ALARM | | | DEVICES.. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | | UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-21 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-24 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-23 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-21 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2021-10-22 14:01:12 | 2ND REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21070505 | | | 10/22/2021 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC. | | | | | | PLAN REVIEW RESULTS: DENIED | | | FAILED COMMENT #5 IS LISTED BELOW WITH ADDITONAL NOTES | | | IN CAP LETTERS. | | | | | | 5) FAILED. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE | | | GAS APPLIANCES. FBC-FUEL GAS SEC. 304.1. WHERE | | | COMBUSTION AIR IS PROVIDED BY THE BUILDING?S MECHANICAL | | | VENTILATION SYSTEM, THE SYSTEM SHALL PROVIDE THE | | | SPECIFIED COMBUSTION AIR RATE IN ADDITION TO THE | | | REQUIRED VENTILATION AIR. FBC-FUEL GAS SEC.304.9.3. I | | | WAS NOT ABLE TO LOCATE THE COMBUSTION AIR CALCULATIONS. | | | PLEASE INDICATE IN THE RESPONSE NARRATIVE WHICH PLAN | | | SHEET SHOWS THE COMBUSTION AIR CALCS AND METHOD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-08-28 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-08-28 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2021-08-28 07:31:37 | 1) SUBMIT THE SIZING TABLE FOR THE PE PIPE FROM THE | | | 2020 FBC-FUEL GAS CODE. WPB AMEND. TO BC SEC. 107.2.1. | | | 2) THE 3/4 INCH METALLIC LINE IS UNDERSIZED TO THE TWO | | | GAS APPLIANCES. THE SYSTEM IS CAPABLE OF HANDLING A | | | MAXIMUM 83 MBTU AT A DISTANCE OF 150 FEET DEVELOPED | | | LENGTH. THE PIPING SHALL BE INCREASED TO 1 INCH PER | | | FBC-FUEL GAS TABLE 402.4 (2). | | | 3) A SEPARATE PERMIT IS REQUIRED FOR THE GAS. PLACE A | | | NOTE TO THIS EFFECT ON THE PLAN. | | | 4) SUBMIT COPIES OF THE GAS EQUIPMENT PECIFICATIONS. | | | ALL GAS EQUIPMENT/ APPLIANCES SHALL BE LISTED AND | | | LABELED PER FBC-FUEL GAS SEC.301.3. | | | 5) ) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE GAS | | | APPLIANCES. FBC-FUEL GAS SEC. 304.1. WHERE COMBUSTION | | | AIR IS PROVIDED BY THE BUILDING?S MECHANICAL | | | VENTILATION SYSTEM, THE SYSTEM SHALL PROVIDE THE | | | SPECIFIED COMBUSTION AIR RATE IN ADDITION TO THE | | | REQUIRED VENTILATION AIR. FBC-FUEL GAS SEC.304.9.3. | | | 6) SHT. P-102. THE PLAN SHOWS THE GAS LINE LABELED AS | | | GW. CLARIFY | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-06 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-06 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-11-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-03 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-09-23 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-02 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-21 |
Time |
05:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-17 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-10 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2021-12-16 13:26:04 | RECEIPT MU-2021-058365 - $102.82 PAID | | 2021-12-10 08:48:45 | 12/10/21 EMAILED IMPACT FOR REVIEW-AO | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-02 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-02 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2021-09-02 08:32:33 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-06 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-06 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-20 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-20 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2021-08-20 15:55:00 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21070505 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE ADD A NOTE TO THE DRAWINGS STATING THAT THE | | | KITCHEN HOODS WILL REQUIRE A SEPARATE PERMIT | | | APPLICATION, DRAWINGS AND REVIEW. THE KITCHEN HOODS | | | WILL NOT BE REVIEWED UNDER THIS PERMIT. | | | | | | 2) PLEASE ADD A NOTE TO THE DRAWINGS STATING THAT THE | | | REFRIGERATION SYSTEMS WILL REQUIRE A SEPARATE PERMIT | | | APPLICATION, DRAWINGS AND REVIEW. THE REFRIGERATION | | | SYSTEMS WILL NOT BE REVIEWED UNDER THIS PERMIT. | | | | | | 3) SHEET -M-102: PLEASE BE MORE SPECIFIC WITH THE USE | | | OF SPACE FOR THE OUTDOOR AIR CALCULATIONS. USING FBC M | | | 403.3.1.1 AND TABLE 403.3.1.1 AND USING KITCHEN AND | | | DINING ROOM AS THE USE OF SPACES. THE REQUIRED OUTDOOR | | | AIR AND KITCHEN EXHAUST IS BELOW: | | | KITCHEN- 214 CFM OF OUTDOOR AIR; KITCHEN 550 CFM OF | | | EXHAUST; BAR- 211 CFM OF OUTDOOR AIR; DINING- 471 CFM | | | OF OUTDOOR AIR. | | | | | | 4) PLEASE PROVIDE A MECHANICAL DRAWING SHOWING THE | | | COMPLETE MECHANICAL SYSTEM. FBC 107.2.1 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-24 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-23 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-21 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2021-10-22 13:27:56 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 21070505 | | | 10/22/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTED IN | | | CAP LETTERS. | | | | | | 8) FAILED. BOTH TOILET ROOMS SHALL BE FULLY ACCESSIBLE | | | AND COMPLY WITH FBC-ACCESS. SEC.213.2. SHOW FULL | | | COMPLIANCE FOR TOILET ROOM #104 ON THE PLANS. THE | | | ARCHITECT IS REFERRING TO SECTION 213.2 EXCEPTION 4 FOR | | | CLUSTERED TOILET ROOMS. THE TOILET ROOMS DO NOT APPEAR | | | TO MEET THE EXCEPTION BECAUSE IT STATES ?NOT MORE THAN | | | 50 PERCENT OF THE SINGLE USE TOILET ROOMS FOR EACH USE | | | AT EACH CLUSTER SHALL BE REQUIRED TO COMPLY WITH 603. | | | IT APPEARS THE INTENT OF THE SECTION WAS TO ALLOW | | | ADDITIONAL TOILET ROOMS OVER AND ABOVE THE MINIMUM | | | REQUIREMENTS TO NOT BE ACCESSIBLE WHEN CLUSTERED | | | TOGETHER. BASED ON THE 48 OCCUPANT LOAD TWO SEPARATE | | | TOILET ROOMS WERE REQUIRED TO BE INSTALLED- ONE F0R | | | MALE AND ONE FOR FEMALE USE (EACH USE). THE FACT THAT | | | THE PLUMBING CODE WHICH IS A COMPLETELY SEPARATE CODE | | | VOLUME ALLOWS THOSE ROOMS TO BE LABELED UNISEX DOES NOT | | | APPEAR TO EXEMPT ONE OF THE ROOMS FROM BEING ACCESSIBLE | | | AS REQUIRED BY 213.2. IF THE INTENT IS TO STAY WITH | | | THIS DESIGN PLEASE PROVIDE A SIGNED AND SEALED LETTER | | | FROM THE ARCHITECT OF RECORD PROVIDING EVIDENCE THAT | | | THE INTENT OF THE CODE IS BEING MET- SECTION 107.1 WPB | | | 12) FAILED. SHT. A-400 - DETAIL #9 - THE DOOR SWINGS | | | INTO THE CLEAR FLOOR SPACE FOR THE LAVATORY AND WATER | | | CLOSET IN BOTH TOILET ROOMS. COMPLY WITH FBC-ACCESS. | | | SEC.603.2.3. TOILET ROOM DOORS ARE NOT PERMITTED TO | | | SWING INTO THE CLEAR FLOOR SPACES PROVIDED FOR | | | FIXTURES. APPROVAL OF THE DOOR SWINGING INWARD WILL | | | DEPEND ON APPROVAL OF THE ROOM AS NON-ACCESSIBLE. | | | | | | 15) FAILED. A HOT WATER RECIRCULATION LINE WILL BE | | | REQUIRED PER FBC-PLUMBING SEC.607.2. IN ACCORDANCE WITH | | | SECTION C404.5.1 AND TABLE C404.5.1 THE MAXIMUM PIPING | | | LENGTH FOR A ?-INCH HOT WATER LINE SUPPLYING A PUBLIC | | | LAVATORY IS 2 FT. THE DESIGNER MUST DECIDE TO EITHER | | | SPECIFY POINT OF USE WATER HEATERS AT THE LAVATORIES OR | | | PROVIDE A RECIRCULATION PUMP FOR THE HW SYSATEM. PLEASE | | | NOTE THAT SECTION 419.5 OF THE FBC P ALLOWS EITHER | | | TEMPERED OR COLD WATER TO BE SUPPLIED TO A LAVATORY. | | | | | | 16) FAILED. SHT.P-101 - INDICATE ON THE PLAN WHAT | | | STANDARD WAS USED IN THE SIZING OF THE GREASE | | | INTERCEPTOR. THE PLAN REFERS TO A CH.24-42-6 FOR | | | CHANGING DFU'S TO GPM. WHAT STANDARD IS THIS FROM? | | | CLARIFY. THE CALCULATION METHOD IS ACCEPTED HOWEVER THE | | | HAND SINK AND FLOOR SINK DRAINAGE LOADS HAVE BEEN ADDED | | | TO THE CALCULATIONS AND THE DRAINAGE FROM THOSE | | | FIXTURES CANNOT GO INTO THE GREASE INTERCEPTOR- SECTION | | | 1003.3.1 FBC P. | | | | | | 17) FAILED. SUBMIT FACTORY SIZING CALCULATIONS FROM | | | SCHIER FOR THE SIZING OF THE GREASE INTERCEPTOR PER | | | FBC-PLUMBING SEC. 1003.2. SEE COMMENT NOTES FOR COMMENT | | | #16. | | | | | | 19) FAILED. SHT. P-103 - THE HAND SINKS SHALL DISCHARGE | | | TO THE SANITARY PER FBC-PLUMBING SEC.1003.3.1. SHEETS | | | P103, P105, RS-3.0: REMOVE CLEAR WATER WASTE DRAINAGE | | | FROM ALL OF THE HAND SINKS AND THE FLOOR SINKS | | | CONVEYING DRAINAGE FROM THE ICE MAKER, WATER DISPENSER, | | | RO SYSTEM, ETC.- SECTION 1003.3.1. | | | | | | 23) FAILED. THE WATER SUPPLY LINE TO THE COFFEE | | | BREWERS, ICE MACHINES, ESPRESSO MACHINE, WATER | | | DISPENSER, REVERSE OSMOSIS SYSTEM SHALL BE PROTECTED | | | WITH A BACKFLOW DEVICE COMPLYING WITH FBC-PLUMBING | | | TABLE 608.1 & ASSE 1024. SHEET P-106: BACKFLOW | | | PREVENTERS FOR LINES SUPPLYING THE RO FILTER AND TANK | | | NOT PROVIDED. TO THE ROUGH-IN SCHEDULE OR PROVIDE A | | | SEPARATE SCHEDULE LISTING THE MAKES AND MODELS AND | | | INSTALLATION LOCATIONS- SECTION 608.3 FBC P. | | | | | | 24) FAILED. ANY CARBONATED BEVERAGE MACHINE SHALL HAVE | | | THE WATER SUPPLY LINE PROTECTED AGAINST BACKFLOW IN | | | COMPLIANCE WITH FBC-PLUMBING TABLE 608.1 AND ASSE 1022. | | | SHEETS P-101 & FS-3.0: TO HELP EXPEDITE THE REVIEW | | | PLEASE ADD THE BACKFLOW DEVICES TO THE ROUGH-IN | | | SCHEDULE OR PROVIDE A SEPARATE SCHEDULE LISTING THE | | | MAKES AND MODELS AND INSTALLATION LOCATIONS- SECTION | | | 608.3 FBC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-08-28 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-08-27 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2021-08-27 05:54:56 | 1) SHT. G103 - PLUMBING SYSTEMS TABLE LISTS GREASE | | | INTERCEPTOR AS "NR" YET ONE IS BEING INSTALLED. LIST | | | THE TYPE, MANUFACTURER, AND SIZE OF THE INTERCEPTOR ON | | | THIS TABLE. | | | 2) SHT. G-104 - THE SIDE WALL GRAB BAR SHALL BE LOCATED | | | IN ACCORDANCE WITH FBC-ACCESS. SEC.604.5.1 & FIGURE | | | 604.5.1. THE LENGTH OF THE GRAB BAR SHALL BE A MINIMUM | | | OF 42 INCHES. | | | 3) SHT. G-104 - THE URINAL SCREEN SHALL BEGIN AT A | | | HEIGHT NOT MMORE THAN 12 INCHES FROM AND EXTEND NOT | | | LESS THAN 60 INCHES ABOVE THE FFINISHED FLOOR SURFACE | | | PER FBC -BUILDING SEC.1210.3.2. THE PLAN SHOWS THE | | | BOTTOM OF THE SCREEN AT 18 INCHES ABOVE THE FINISH | | | FLOOR. | | | 4) SHT. G-104 - WATER COOLER (DOUBLE) - SHOW COMPLIANCE | | | WITH FBC-ACCESS. SEC. 602.7 FOR THE SPOUT OUTLET HEIGHT | | | FOR STANDING PERSONS. | | | 5) SHT. G-104 - ROOM SIGNAGE - TACTILE CHARACTERS ON | | | SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE | | | FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | | BASELINE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES | | | MMAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, | | | MEASUURED FROM THE BASELINE OF THE HIGHEST TACTILE | | | CHARACTER. FBC-ACCESS. SEC. 703.4.1. | | | 6) SHT. B-101 SHOWS THE OCCUPANT LOAD OF THIS SPACE AS | | | 49 PERSONS.A BUILDING OR TENANT SPACE USED FOR ASSEMBLY | | | PURPOSES WITH AN OCCCUPANT LOAD OF LES THAN 50 PERSONS | | | SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY.THE PLANS | | | CLASSIY THIS OCCUPANCY AS AN A-2 OCUPANCCY. CLARIFY | | | 7) THE REQUIRED PLUMBING FIXTURES SHALL BE BASED ON A B | | | OCCUPANCY PER FBC-PLUMBING TABLE 403.1. | | | 8) BOTH TOILET ROOMS SHALL BE FULLLY ACCESSIBLE AND | | | COMPLY WITH FBC-ACCESS. SEC.213.2. SHOW FULL COMPLIANCE | | | FOR TOILET ROOM #104 ON THE PLANS. | | | 9) SHOW THE LOCATION OF THE REQUIRED DRINKING FOUNTAIN | | | ON THE PLAN AND THE REQUIRED CLEAR FLOOR SPACE FOR THE | | | FIXTURE PER FBC-ACCESS. SEC.305 & 602.2. | | | 10) SHT. B-101 NOTES THE SQUARE FOOTAGE OF THIS SPACE | | | AS 1797 SQUARE FEET AND SHT. A-001 NOTES THE SQUARE | | | FOOTAGE AS 1039 SQUARE FEET. CLARIFY. | | | 11) SHT. AD-100 IS MISSING A DIGITAL SEAL & SIGNATURE. | | | COMPLY WITH FL. ADMIN. CODE RULE 61G1-16.005. | | | 12) SHT. A-400 - DETAIL #9 - THE DOOR SWINGS INTO THE | | | CLEAR FLOOR SPACE FOR THE LAVATORY AND WATER CLOSET IN | | | BOTH TTOILET ROOMS. COMPLY WITH FBC-ACCESS. | | | SEC.603.2.3. | | | 13) SHT. A-420 - DEATIL #4 - WHERE IS THIS FIXTURE | | | LOCATED? SHOW ON THE PLANS. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 14) SHT.ID-101 - FINISH MATERIAL CT-2 IS NOT LISTED ON | | | THE FINISH SCHEDULE. CLARIFY. | | | 15) A HOT WATER RECRCULATION LINE WILL BE REQUIRED PER | | | FBC-PLUMBING SEC.607.2. | | | 16) SHT.P-101 - INDICATE ON THE PLAN WHAT STANDARD WAS | | | USED IN THE SIZING OF THE GREASE INTERCEPTOR.THE PLAN | | | REFERS TO A CH.24-42-6 FOR CHANGING DFU'S TO GPM. WHAT | | | STANDARD IS THIS FROM? CLARIFY. | | | 17) SUBMIT FACTORY SIZING CALCULATIONS FROM SCHIER FOR | | | THE SIZING OF THE GREASE INTERCEPTOR PER FBC-PLUMBING | | | SEC. 1003.2. | | | 18) SUBMIT A DETAIL OF THE GREASE INTERCEPTOR THAT IS | | | BEING INSTALLED. FBC-PLUMBING SEC. 1003.2. | | | 19) SHT. P-103 - THE HAND SINKS SHALL DISCHARGE TO THE | | | SANITARY PER FBC-PLUMBING SEC.1003.3.1. | | | 20) TRAP PRIMERS ARE REQUIRED ON THE FLOOR DRAINS PER | | | FBC-PLUMBING SEC.1002.4.1. | | | 21) SHT. P-105 SHOWS THE DRAIN FROM EVAPORATOR W18A | | | DISCHARGING TO THE GRESE WASTE SYSTEM. THE CONDENSATE | | | SHALL DISCHARGE TO THE SANITARY OR THE STORM SYSTEM. | | | FBC-PLUMBING SEC.1003.2. | | | 22) SHT. P-104 CALLS OUT A NEW 1 1/2 INCH SHUTOFF VALVE | | | ON THE WATER SUPPLY LINE BY THE TOILET ROOMS YET P-106 | | | CALLS OUT THIS LINE AS 1 1/4. CLARIFY. | | | 23) THE WATER SUPPLY LINE TO THE COFFE BREWERS, ICE | | | MACHINES, ESPRESSO MACHINE, WATER DISPENSER, REVERSE | | | OSMOSIS SYSTEM SHALL BE PROTECTED WITH A BACKFLOW | | | DEVICE COMPLYING WITH FBC-PLUMBING TABLE 608.1 & ASSE | | | 1024. | | | 24) ANY CARBONATED BEVERAGE MACHINE SHALL HAVE THE | | | WATER SUPPY LINE PROTECTED AGAINST BACKFLOW IN | | | COMPLIANCE WITH FBC-PLUMBING TABLE 608.1 AND ASSE 1022. | | | 25)THE DISHWASHER SHALL BE EQUIPPED WITH A BACKFLOW | | | DEVICE. FBC-PLUMBING SEC. 608.16. | | | 26) THE FOOD SEVICE PLANS ON THEM IN THE LOWER RIGHT | | | HAND CORNER THAT READS "NOT FOR CONSTRUCTION". CLARIFY. | | | 27) THE FOOD SERVICE PLANS HAVE NOT BEEN SIGNED & | | | SEALED BY THE ARCHITECT OF RECORD ALTHOUGH THE TITLE | | | BLOCK IS ON THE PLANS. COMPLY WITH FL. ADMIN. CODE RULE | | | 61G1-16.005. | | | 28) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | KITCHEN EQUIPMENT PER WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-24 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-23 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2021-11-24 12:57:20 | A SEPARATE PERMIT IS REQUIRED ROR INSTALLATION OF THE | | | GREASE INTERCEPTOR. |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-21 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2021-10-22 14:04:24 | 2ND REVIEW FBC-2020 GREASE WASTE | | | PERMIT- 21070505 | | | 10/22/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTED IN | | | CAP LETTERS. | | | | | | 16) FAILED. SHT.P-101 - INDICATE ON THE PLAN WHAT | | | STANDARD WAS USED IN THE SIZING OF THE GREASE | | | INTERCEPTOR. THE PLAN REFERS TO A CH.24-42-6 FOR | | | CHANGING DFU'S TO GPM. WHAT STANDARD IS THIS FROM? | | | CLARIFY. THE CALCULATION METHOD IS ACCEPTED HOWEVER THE | | | HAND SINK AND FLOOR SINK DRAINAGE LOADS HAVE BEEN ADDED | | | TO THE CALCULATIONS AND THE DRAINAGE FROM THOSE | | | FIXTURES CANNOT GO INTO THE GREASE INTERCEPTOR- SECTION | | | 1003.3.1 FBC P. | | | | | | 17) FAILED. SUBMIT FACTORY SIZING CALCULATIONS FROM | | | SCHIER FOR THE SIZING OF THE GREASE INTERCEPTOR PER | | | FBC-PLUMBING SEC. 1003.2. SEE COMMENT NOTES FOR COMMENT | | | #16. | | | | | | 19) FAILED. SHT. P-103 - THE HAND SINKS SHALL DISCHARGE | | | TO THE SANITARY PER FBC-PLUMBING SEC.1003.3.1. SHEETS | | | P103, P105, RS-3.0: REMOVE CLEAR WATER WASTE DRAINAGE | | | FROM ALL OF THE HAND SINKS AND THE FLOOR SINKS | | | CONVEYING DRAINAGE FROM THE ICE MAKER, WATER DISPENSER, | | | RO SYSTEM, ETC.- SECTION 1003.3.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-08-28 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-08-28 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2021-08-28 07:14:55 | 1) SHT.P-101 - INDICATE ON THE PLAN WHAT STANDARD WAS | | | USED IN THE SIZING OF THE GREASE INTERCEPTOR.THE PLAN | | | REFERS TO A CH.24-42-6 FOR CHANGING DFU'S TO GPM. WHAT | | | STANDARD IS THIS FROM? CLARIFY. | | | 2) SUBMIT FACTORY SIZING CALCULATIONS FROM SCHIER FOR | | | THE SIZING OF THE GREASE INTERCEPTOR PER FBC-PLUMBING | | | SEC. 1003.2. | | | 3) A SEPARATE PERMIT WILL BE REQUIRED FOR THE GREASE | | | INTERCEPTOR. PLACE THIS NOTE ON THE PLAN. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-06 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-06 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-22 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-22 |
Time |
15:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-13 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-13 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-02 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-02 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2021-10-01 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-10-01 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2021-10-01 09:53:02 | PROVISO: SIGNAGE IS UNDER A SEPARATE PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-04 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-08-04 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-08-04 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2021-08-04 16:04:46 | - PLEASE INDICATE, NOTE, OR SHOW THE ADDITIONAL/TOTAL | | | SQUARE FOOTAGE GAINED FROM THE REMOVAL OF THE RECESSED | | | DOOR AREA (D08 & D03 ON AD-100 - CENTER LEFT OF | | | BUILDING) THAT'S PROPOSED AS INTERIOR SPACE AND IS | | | FLUSH WITH THE FACADE ALONG ROSEMARY AVE. | | | | | | - SIGNAGE IS UNDER A SEPARATE PERMIT. |
|
|