| Plan Review Stops For Permit 21070481 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-10 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-10 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2021-12-10 13:37:32 | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE: SUBMIT FOR REVIEW PRIOR TO INSPECTIONS TO AVOID | | | CONFLICT/DELAYS): | | | 1)MUD ROOM ADDITION: NEED COMPLETE ROOF FRAMING PLAN | | | FOR CONVENTIONAL FRAMING. SHOW ALL STRUCTURAL FRAMING | | | MEMBERS AND CONNECTORS AT EACH END. | | | | | | 2)WALL SECTION (SHEET A202):PROVIDE ROOF SHEATHING | | | COMPLETE INFORMATION. PLYWOOD THICKNESS AND FASTENING. | | | SEE SEC. R803 FBC-RESIDENTIAL. NOTE: COORDINATE WITH | | | CURRENT CEDAR SHINGLES PRODUCT APPROVAL. PROVIDE | | | COMPLETE SPECS FOR WALL SHEATHING, EXTERIOR FINISH, | | | FLOOR JOISTS CONNECTION TO NEW STEM WALL AND EXISTING | | | WALL. PROVIDE COMPLETE SPECS FOR STEM WALL BEAM, ETC. | | | | | | 3)PROVIDE COMPLETE PRODUCT APPROVAL (NEED COVER PAGE & | | | COMPLETE INSTALLATION DWGS)FOR: | | | A)CEDAR SHINGLES. PROVIDE COMPLETE CURRENT PRODUCT | | | APPROVAL SHOWING COMPLIANCE WITH SEC. R905.7 | | | FBC-RESIDENTIAL. | | | B)SKYLIGHT. | | | C)WINDOW MULLIONS. NOTE: NEED TO SPECIFY MULLION SIZE. | | | D)CASEMENT WINDOWS. NOTE: MULLION HIGHLIGHTED ON SHEET | | | 13 OF 28 DOESN'T MEET THE CALCULATED DESIGN PRESSURES. | | | NEED TO REVISE SIZE. | | | E)DOUBLE HUNG WINDOWS. | | | F)EXTERIOR DOORS. | | | G)FIXED WINDOWS. IF REPLACED. | | | D)HURRICANE SHUTTERS AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | | | | 4)ARCHITECT OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | | APPROVALS. | | | | | | 5)PROVIDE STAIRWAY, STAIRS, HANDRAILS, GUARDRAILS SHOP | | | DRAWINGS REVIEWED BY ARCHITECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-17 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-17 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2021-11-17 16:15:29 | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE: SUBMIT FOR REVIEW PRIOR TO INSPECTIONS TO AVOID | | | CONFLICT/DELAYS): | | | 1)MUD ROOM ADDITION: NEED COMPLETE ROOF FRAMING PLAN | | | FOR CONVENTIONAL FRAMING. SHOW ALL STRUCTURAL FRAMING | | | MEMBERS AND CONNECTORS AT EACH END. | | | | | | 2)WALL SECTION (SHEET A202):PROVIDE ROOF SHEATHING | | | COMPLETE INFORMATION. PLYWOOD THICKNESS AND FASTENING. | | | SEE SEC. R803 FBC-RESIDENTIAL. NOTE: COORDINATE WITH | | | CURRENT CEDAR SHINGLES PRODUCT APPROVAL. PROVIDE | | | COMPLETE SPECS FOR WALL SHEATHING, EXTERIOR FINISH, | | | FLOOR JOISTS CONNECTION TO NEW STEM WALL AND EXISTING | | | WALL. PROVIDE COMPLETE SPECS FOR STEM WALL BEAM, ETC. | | | | | | 3)PROVIDE COMPLETE PRODUCT APPROVAL (NEED COVER PAGE & | | | COMPLETE INSTALLATION DWGS)FOR: | | | A)CEDAR SHINGLES. PROVIDE COMPLETE CURRENT PRODUCT | | | APPROVAL SHOWING COMPLIANCE WITH SEC. R905.7 | | | FBC-RESIDENTIAL. | | | B)SKYLIGHT. | | | C)WINDOW MULLIONS. NOTE: NEED TO SPECIFY MULLION SIZE. | | | D)CASEMENT WINDOWS. NOTE: MULLION HIGHLIGHTED ON SHEET | | | 13 OF 28 DOESN'T MEET THE CALCULATED DESIGN PRESSURES. | | | NEED TO REVISE SIZE. | | | E)DOUBLE HUNG WINDOWS. | | | F)EXTERIOR DOORS. | | | G)FIXED WINDOWS. IF REPLACED. | | | D)HURRICANE SHUTTERS AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | | | | 4)ARCHITECT OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | | APPROVALS. | | | | | | 5)PROVIDE STAIRWAY, STAIRS, HANDRAILS, GUARDRAILS SHOP | | | DRAWINGS REVIEWED BY ARCHITECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-08 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-08 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2021-10-08 16:30:25 | RESIDENTIAL (R3) ALTERATION. SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21070481 | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | ORIGINAL COMMENT: | | | 1- ARCHITECT TO PROVIDE ALL THE WIND DESIGN CRITERIA AS | | | REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. SPECIFY THE | | | ULTIMATE AND NOMINAL WIND LOAD, BUILDING EXPOSURE, | | | BUILDING MEAN ROOF HEIGHT. ALSO, SPECIFY THE COMPONENTS | | | AND CLADDING DESIGN PRESSURES FOR DOORS AND WINDOWS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | 2- OK | | | 3- OK | | | | | | ORIGINAL COMMENT. | | | 4- SECOND FLOOR WINDOW OPENING CONTROL DEVICES: WINDOW | | | OPENING CONTROL DEVICES IN WINDOW REPLACEMENT ARE | | | REQUIRED WHEN THE TOP SILL OF THE WINDOW OPENING IS AT | | | A HEIGHT LESS THAN 24 INCHES (610 MM) ABOVE THE | | | FINISHED FLOOR. | | | CLEARLY SPECIFY IF THERE ARE ANY WINDOWS WHERE THE | | | WINDOW SILL IS LESS THAN 24" ABOVE THE FINISH FLOOR. | | | SEE SEC. 702.4 FBC-EXISTING BUILDING CODE. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. BASED ON THE WINDOW | | | SCHEDULE, IT LOOKS LIKE SOME WINDOWS WILL NEED OPENING | | | CONTROL DEVICES. PLEASE IDENTIFY OPENINGS WITH WINDOW | | | SILL LESS THAN 2'-0". | | | | | | 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)EXTERIOR DOORS. (IF REPLACED). OR NEW DOOR. | | | B)WINDOWS (IF REPLACED). SINGLE HUNG, CASEMENT AND | | | FIXED WINDOWS. OR NEW WINDOWS. | | | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE | | | TO AVOID DELAYS/CONFLICTS). | | | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | E)ROOFING MATERIAL SPECIFIED ON PLANS. | | | F)ROOFING UNDERLAYMENT AS SPECIFIED ON PLANS AND | | | APPROVED FOR PROPOSED ROOFING. | | | F)SKYLIGHT AS SHOWN ON PLANS. | | | | | | ORIGINAL COMMENT: | | | 6- INTERIOR DEMOLITION PERMIT SHOWS ROOFING REMOVAL. | | | ARCHITECT OF RECORD TO SPECIFY ROOFING UNDERLAYMENT | | | SHOWING COMPLIANCE WITH SEC. R905.1.1.1 | | | FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REVISED PLANS SPECIFY ALASKAN YELLOW CEDAR SHINGLES. | | | ARCHITECT OF RECORD NEEDS TO SPECIFY ONE OF THE | | | UNDERLAYMENT METHODS SHOWING COMPLIANCE WITH SEC. | | | R905.1.1.3 FBC-RESIDENTIAL. ICE & WATER SHIELD | | | SPECIFIED ON THE WALL SECTION ON SHEET A202 IS NOT | | | SPECIFIED ON THE NEW CODE SECTION. REVISE AS REQUIRED. | | | | | | 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 8- DEMOLITION PLANS SHOW REMOVAL OF WALLS BY THE | | | STAIRWAY. NO INFORMATION WAS PROVIDED FOR THE NEW | | | GUARDRAIL AND HANDRAIL. PROVIDE COMPLETE DETAILS AND | | | SPECIFICATIONS SHOWING COMPLIANCE WITH SEC. R312.1 | | | FBC-RESIDENTIAL AND SEC. R311.7.8 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | 9- OK. | | | 10- OK. | | | | | | ORIGINAL COMMENT: | | | 11- VALUATION DECLARED IN THE PERMIT APPLICATION IS | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. | | | REVISE VALUATION TO INCLUDE ALL THE SCOPE OF WORK. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | NEW COMMENTS BASED ON REVISED PLANS SUBMITTED: | | | 12- NEW PLANS SHOW A MUDROOM ADDITION. PROVIDE | | | FOUNDATION, FLOOR FRAMING AND ROOF FRAMING PLANS WITH | | | COMPLETE DETAILS AND SPECIFICATIONS. SPECIFY ALL | | | FRAMING MEMBERS AND CONNECTORS AT EACH END. SPECIFY | | | ROOF SHEATHING FASTENING. SEC. R301.1 FBC-RESIDENTIAL. | | | SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | 13- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | FOR NEW SKYLIGHT, NEW DOOR AND NEW WINDOW. SPECIFY ALL | | | FRAMING MEMBERS AND CONNECTORS. SEC. R301.1 | | | FBC-RESIDENTIAL. SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | 14- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | | CONSTRUCTION OF THE NEW FIREPLACE AND CHIMNEY AS SHOWN | | | ON PLANS. SEC. R301.1 FBC-RESIDENTIAL. SEC. 107.3.5.3 | | | CITY AMENDMENTS. | | | | | | 15- ARCHITECT TO PROVIDE SPECIFICATIONS FOR PROTECTION | | | OF NEW FLOOR JOISTS AGAINST DECAY AS REQUIRED BY SEC. | | | R317.1 FBC-RESIDENTIAL. | | | | | | 16- SPECIFY CARBON MONOXIDE ALARM WITHIN ALL SLEEPING | | | ROOMS, INCLUDING EXISTING BEDROOMS AS REQUIRED BY SEC. | | | R315.1 FBC-RESIDENTIAL. | | | | | | 17- WINDOW SCHEDULE ON SHEET A601: | | | IT IS NOT CLEAR WHY THERE IS A MISCELLANEOUS NOTE | | | STATING "NOT APPROVED BY W.P.B. H.P.B". CLARIFY WHAT IS | | | THIS NOTE FOR? | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-08-18 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-08-18 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2021-08-18 15:53:40 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21070481 | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | 1- ARCHITECT TO PROVIDE ALL THE WIND DESIGN CRITERIA AS | | | REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. SPECIFY THE | | | ULTIMATE AND NOMINAL WIND LOAD, BUILDING EXPOSURE, | | | BUILDING MEAN ROOF HEIGHT. ALSO, SPECIFY THE COMPONENTS | | | AND CLADDING DESIGN PRESSURES FOR DOORS AND WINDOWS. | | | | | | 2- THE DEMOLITION PLANS SUBMITTED UNDER THIS | | | APPLICATION AND THE DEMOLITION PLANS SHOWN UNDER PERMIT | | | #21080674 DON'T MATCH. REVISE AS REQUIRED TO MATCH TO | | | AVOID CONFLICTS/DELAYS. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 3- SCOPE OF WORK IS NOT CLEAR. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | ARE EXISTING WINDOWS AND EXTERIOR DOORS GOING TO BE | | | REPLACED?. IF SO, THEN SPECIFIC THE EXISTING WINDOW | | | TYPE AND SIZE AND SPECIFY PROPOSED WINDOW TYPE AND SIZE | | | TO VERIFY COMPLIANCE WITH SEC. 7025 FBC-EXISTING | | | BUILDING. FOR EXTERIOR SWING DOORS, SPECIFY EXISTING | | | DOOR SIZE AND PROPOSED SIZE. | | | | | | 4- SECOND FLOOR WINDOW OPENING CONTROL DEVICES: WINDOW | | | OPENING CONTROL DEVICES IN WINDOW REPLACEMENT ARE | | | REQUIRED WHEN THE TOP SILL OF THE WINDOW OPENING IS AT | | | A HEIGHT LESS THAN 24 INCHES (610 MM) ABOVE THE | | | FINISHED FLOOR. | | | CLEARLY SPECIFY IF THERE ARE ANY WINDOWS WHERE THE | | | WINDOW SILL IS LESS THAN 24" ABOVE THE FINISH FLOOR. | | | SEE SEC. 702.4 FBC-EXISTING BUILDING CODE. | | | | | | 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)EXTERIOR DOORS. (IF REPLACED). | | | B)WINDOWS (IF REPLACED) | | | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE | | | TO AVOID DELAYS/CONFLICTS). | | | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | E)ROOFING MATERIAL. | | | | | | 6- INTERIOR DEMOLITION PERMIT SHOWS ROOFING REMOVAL. | | | ARCHITECT OF RECORD TO SPECIFY ROOFING UNDERLAYMENT | | | SHOWING COMPLIANCE WITH SEC. R905.1.1.1 | | | FBC-RESIDENTIAL. | | | | | | 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 8- DEMOLITION PLANS SHOW REMOVAL OF WALLS BY THE | | | STAIRWAY. NO INFORMATION WAS PROVIDED FOR THE NEW | | | GUARDRAIL AND HANDRAIL. PROVIDE COMPLETE DETAILS AND | | | SPECIFICATIONS SHOWING COMPLIANCE WITH SEC. R312.1 | | | FBC-RESIDENTIAL AND SEC. R311.7.8 FBC-RESIDENTIAL. | | | | | | 9- DEMOLITION PLANS CALLS FOR REMOVAL OF WALLS BY THE | | | MASTER BEDROOM ENTRY AREA. NEED TO PROVIDE COMPLETE | | | DETAILS AND SPECIFICATIONS FOR THE NEW WALLS. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | 10- PROPOSED FIRST FLOOR PLAN SHOWS THE CONVERSION OF | | | THE FLORIDA ROOM | | | TO BAR LOUNGE. THE FLORIDA ROOM WAS NOT PART OF THE | | | HEATED (AND AIR CONDITIONED) SPACE OF THE MAIN HOUSE. | | | BASED ON THE PROPOSED PLAN, IT LOOKS LIKE NOW THE BAR | | | LOUNGE IS GONG TO BE PART OF THE HEATED SPACE OF THE | | | MAIN HOUSE. ARCHITECT TO PROVIDE DETAILS/SPECIFICATIONS | | | SHOWING HOW THIS ROOM IS GOING TO BE HEATED AS REQUIRED | | | BY SEC. R303.10 FBC-RESIDENTIAL. | | | | | | 11- VALUATION DECLARED IN THE PERMIT APPLICATION IS | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. | | | REVISE VALUATION TO INCLUDE ALL THE SCOPE OF WORK. | | | | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-09 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-09 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-18 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-18 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2021-10-18 11:51:34 | SEE PERMIT #21081237 FOR THE ELECTRICAL WORK FOR THIS | | | PROJECT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-10-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-10-11 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-10-11 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2021-10-11 19:40:59 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SMOKE/CO ALARMS REQUIRED PER FBC-RE 314 AND 315 | | | | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | | | | 3. ARC-FAULT PROTECTION REQUIRED PER NEC 210.12A, | | | 210.12B | | | | | | 4. TAMPERPROOF RECEPTACLES REQUIRED PER NEC 406.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-07-29 |
Time |
20:14 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-07-29 |
Time |
19:18 |
Sent To |
|
|
| Notes |
| 2021-07-29 20:14:32 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY | | | THE ELECTRICAL CONTRACTOR QUALIFIER. . FS | | | 471.003(2)(H); 471.025; WPB FBC 107.2.1, 107.3.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-10 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-10 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-11-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-02 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-02 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2021-11-02 17:25:58 | 2ND REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21070481 | | | 11/2/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A100 GAS RISER: PLEASE CORRECT THE NOTE | | | INDICATING A 1 PSI SYSTEM AT THE SERVICE REGULATOR- | | | SECTION G2413.1 FBC RES. | | | | | | 2) A100 GAS RISER: PLEASE INDICATE THE SIZE OF THE PIPE | | | FROM THE METER TO THE FIRST TEE- G24313.3 FBC RES. | | | | | | 3) A100: CONCERNING COMBUSTION AIR FOR THE RANGE PLEASE | | | USE ONE OF THE METHODS LISTED UNDER SECTION G2407.1 FBC | | | RES. THE RESPONSE NARRATIVE IS INDICATING THE MAKEUP | | | AIR FOR THE EXHAUST HOOD IS THE SOURCE OF THE | | | COMBUSTION AIR, HOWEVER THE MAKEUP AIR IS DEDICATED FOR | | | REPLACEMENT OF THE HOOD EXHAUST AIR. | | | | | | 4) A100: COMMENT #5 FROM THE 1ST REVIEW PRINTED BELOW | | | WAS PARTIALLY ADDRESSED. PLEASE PROVIDE THE REQUESTED | | | MANUFACTURER'S SPECIFICATIONS AND VENTING PLAN. | | | | | | 5) PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW FIREPLACE | | | AND SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION MANUAL - SECTION G2434.1 FBC RES. PROVIDE | | | COMBUSTION AIR AND VENTING PLANS FOR THE FIREPLACE IN | | | ACCORDANCE WITH MANUFACTURER?S GUIDELINES. PLEASE | | | INCLUDE COMBUSTION AIR CALCULATIONS, AND A VENTING | | | DIAGRAM WHICH SHOWS THE TYPE AND SIZE OF VENT | | | PIPES/DUCTS, VENT RUN LENGTHS AND VENT TERMINATION | | | LOCATION- REFER TO SPECS AND SECTION G2427 FBC RES. | | | | | | 6) A101: SHOW THE GAS DRYER VENT RUN AND SPECIFICTIONS, | | | AND INDICATE HOW AIR IS BEING PROVIDED TO THE | | | APPLIANCE- SECTION G2439.1 & G2439.4 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-29 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2021-09-30 08:28:01 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21070481 | | | 9/28/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS A100 & A101: THE GAS PIPING AND APPLIANCE | | | INSTALLATIONS FOR THE PROPOSED PROJECT SHALL BE | | | DESIGNED AND INSTALLED IN ACCORDANCE WITH THE FBC- 2020 | | | 7TH EDITION RESIDENTIAL CODE. PLEASE PROVIDE DESIGN | | | CRITERIA ON THE PLANS. | | | | | | 2) PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES | | | ALL NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE | | | RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO | | | FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL SHOW: | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | H) OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | 3) PLEASE NOTE THAT THE MOST RECENT GAS PERMIT AT THE | | | RESIDENCE WAS PERMIT #04121077. WPB BUILDING DEPT. | | | RECORDS INDICATE A 505,000 BTU SYSTEM WITH AN EXISTING | | | RANGE, STORAGE TYPE WATER HEATER AND A NEW POOL HEATER. | | | THERE IS NO RECORD OF AN EXTERIOR TANKLESS GAS-FIRED | | | WATER HEATER BEING LEGALLY PERMITTED THEREFORE IT SHALL | | | BE REVIEWED AS A NEW WATER HEATER. PLEASE SUBMIT | | | MANUFACTURER?S SPECIFICATIONS AND INSTALLATION MANUAL | | | FOR THE WATER HEATER. PROVIDE AN EQUIPMENT SCHEDULE ON | | | THE PLAN INDICATING THE MAKE AND MODEL, BTUH LOAD, AND | | | EFFICIENCY RATING- TABLE C404.2 FBC EC. PROVIDE A | | | DETAIL SHOWING THE INSTALLATION LOCATION AND REQUIRED | | | CLEARANCES AS RECOMMENDED BY THE MANUFACTURER- SECTIONS | | | G2406.1 & G2448.1 FBC RES. | | | | | | 4) PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW RANGE AND | | | SUBMIT MANUFACTURER'S SPECIFICATIONS- SECTION G2447.1 | | | FBC RES. PROVIDE COMBUSTION AIR CALCULATIONS AND | | | INDICATE HOW THE AIR WILL BE PROVIDED- SECTION G2407.1 | | | FBC RES. | | | | | | 5) PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW FIREPLACE | | | AND SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION MANUAL - SECTION G2434.1 FBC RES. PROVIDE | | | COMBUSTION AIR AND VENTING PLANS FOR THE FIREPLACE IN | | | ACCORDANCE WITH MANUFACTURER?S GUIDELINES. PLEASE | | | INCLUDE COMBUSTION AIR CALCULATIONS, AND A VENTING | | | DIAGRAM WHICH SHOWS THE TYPE AND SIZE OF VENT | | | PIPES/DUCTS, VENT RUN LENGTHS AND VENT TERMINATION | | | LOCATION- REFER TO SPECS AND SECTION G2427 FBC RES. | | | | | | 6) INDICATE THE MAKES AND MODELS OF REGULATORS TO BE | | | INSTALLED ON THE SYSTEM AND SUBMIT MANUFACTURER?S | | | SPECIFICATIONS MARKED UP TO SHOW THE SELECTED MODELS, | | | AND INPUT AND OUT PIPE SIZES AND PRESSURES- SECTION | | | G2421.2 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-10-18 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-10-18 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-08-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-08-24 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-08-24 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-10 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-06 |
Time |
14:58 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-17 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-29 |
Time |
08:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-19 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-23 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-08-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2021-07-27 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-22 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-15 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2021-12-22 09:34:20 | RECEIPT MU-2021-58870 - $2291.74 PAID | | | | | 2021-12-15 08:01:13 | 12/15/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-08-18 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-08-18 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2021-08-18 15:58:17 | IMPACT FEES REVIEW: | | | CHANGING THE USE OF THE COVERED FLORIDA ROOM TO LIVABLE | | | AREA. PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY | | | FOR IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-10 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-10 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-11-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-02 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-02 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-29 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-29 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2021-09-29 17:09:41 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21070481 | | | 9/28/21 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A100 SANITARY RISER: SHOW A 2-INCH FIXTURE | | | DRAIN FOR THE WASHING MACHINE CONNECTING TO A MINIMUM | | | 3-INCH STACK AND BRANCH DRAIN- SECTION 406.2 FBC P. | | | | | | 2) A101: SHOW THE LOCATIONS OF THE WASHING MACHINE | | | SHUTOFF VALVES TO VERIFY THEY WILL BE IN A LOCATION | | | WITH ACCESS- SECTION P2903.5.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-07-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-30 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-30 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2021-07-30 13:11:48 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 21070481 | | | 7/30/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE PLUMBING PLANS, SPECIFICATIONS, | | | FIXTURE AND APPLIANCE SCHEDULES, AND RISER DRAWINGS FOR | | | REVIEW SECTIONS 107.1 AND 107.3.5.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-17 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-17 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2021-11-17 16:17:50 | ROOFING REVIEW APPROVED WITH PROVISO | | | (NOTE: SUBMIT FOR REVIEW PRIOR TO INSPECTIONS TO AVOID | | | CONFLICT/DELAYS): | | | | | | 1)PROVIDE COMPLETE PRODUCT APPROVAL (NEED COVER PAGE & | | | COMPLETE INSTALLATION DWGS)FOR: | | | A)CEDAR SHINGLES. PROVIDE COMPLETE CURRENT PRODUCT | | | APPROVAL SHOWING COMPLIANCE WITH SEC. R905.7 | | | FBC-RESIDENTIAL. | | | | | | 2)ARCHITECT OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | | APPROVALS. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-10-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-08 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-08 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2021-10-08 14:56:12 | ROOFING REVIEW: | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)ROOFING MATERIAL SPECIFIED ON PLANS. | | | B) ROOFING UNDERLAYMENT AS SPECIFIED ON PLANS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-10 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-10 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-17 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-17 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-10-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-08 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-08 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-08-18 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-08-18 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2021-08-18 16:05:25 | SIGNATURE REVIEW COMMENTS: | | | | | | 1- ALL DRAWINGS NEED ARCHITECT'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY SEC. 481 F.S. WHEN | | | SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | | PLANS SUBMITTED HAVE A COPY OF A DIGITAL SIGNATURE. | | | PLANS WITH DIGITAL SIGNATURE ARE NOT ALLOWED TO BE | | | PRINTED. NEED PLANS SUBMITTED ELECTRONICALLY WITH | | | ARCHITECT'S ORIGINAL DIGITAL SIGNATURE OR PROVIDE HARD | | | COPY PLANS WITH THE ORIGINAL SEAL AND SIGNATURE. | | | | | | ARCHITECTS | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-10-18 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-10-18 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-08-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-08-24 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-08-24 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|