Plan Review Details - Permit 21070456
Plan Review Stops For Permit 21070456
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-08-02 Cont ID  
Sent By jbrooks Date 2021-08-02 Time 13:26 Rev Time 0.00
Received By jbrooks Date 2021-08-02 Time 07:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-28 Cont ID  
Sent By jbrooks Date 2021-07-28 Time 13:10 Rev Time 0.00
Received By jbrooks Date 2021-07-28 Time 11:48 Sent To  
Notes
2021-07-28 13:11:14JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R8 SELECTED OPTION FOR SYSTEM NO W-2;
 EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15);
 ULTIMATE WIND SPEED (170). ZONE 3 IS MARKED ?N/A? WHICH
 INDICATES SYSTEM IS ?NOT APPLICABLE? TO ZONE1 PRIME
 DESIGN PRESSURE REQUIREMENTS AND CANNOT BE USED. PLEASE
 PROVIDE 2020 CODE VERSION PRODUCT APPROVAL/NOA THAT
 MEETS OR EXCEEDS DESIGN PRESSURE REQUIREMENTS FOR
 EXPOSURE C AREAS. YOU MAY WANT TO CONSIDER USING SYSTEM
 W-3.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-02 Cont ID  
Sent By jbrooks Date 2021-08-02 Time 13:27 Rev Time 0.00
Received By jbrooks Date 2021-07-30 Time 11:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-28 Cont ID  
Sent By jbrooks Date 2021-07-28 Time 13:11 Rev Time 0.00
Received By jbrooks Date 2021-07-13 Time 17:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-08-03 Cont ID  
Sent By jbrooks Date 2021-08-03 Time 08:31 Rev Time 0.00
Received By jbrooks Date 2021-08-03 Time 08:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-08-02 Cont ID  
Sent By jbrooks Date 2021-08-02 Time 13:26 Rev Time 0.00
Received By jbrooks Date 2021-08-02 Time 13:13 Sent To  
Notes
2021-08-02 13:26:46JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO ME, OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED
 AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 PETER VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6673.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-07-28 Cont ID  
Sent By jbrooks Date 2021-07-28 Time 13:11 Rev Time 0.00
Received By jbrooks Date 2021-07-28 Time 11:48 Sent To  
Notes
***NONE***