|
 |
 |
 |
 |
 |
Plan Review Details - Permit 21070374
| Plan Review Stops For Permit 21070374 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-09 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-09 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-01 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-01 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-28 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-28 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2021-07-28 12:24:56 | 2ND FLOOR TRELLIS | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) DRAWING A001 NOTE NUMBER 1 - SHOWS DESIGN PER 2017 | | | FBC - SHOULD BE 2020 FBC. | | | 2) PLEASE SHOW THE EXISTING BUILDING CONSTRUCTION TYPE | | | PER FBC CHAPTER 6 | | | 3) WOOD FRAMING MAY NEED TO BE FIRE RETARDANT PER FBC | | | 602.2 TYPES I AND II. | | | TYPES I AND II CONSTRUCTION ARE THOSE TYPES OF | | | CONSTRUCTION IN WHICH THE BUILDING ELEMENTS LISTED IN | | | TABLE 601 ARE OF NONCOMBUSTIBLE MATERIALS, EXCEPT AS | | | PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-29 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-29 |
Time |
06:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-10-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-26 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-13 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2021-07-13 11:55:02 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE PROPOSED TRELLIS INSTALLATION APPEARS TO IMPACT | | | AND OBSTRUCTT THE EXISTING FIRE SPRINKLER PROTECTION | | | SYSTEM. | | | | | | A REVIEW BY A CERTIFIED FIRE SPRINKLER CONTRACTOR IS | | | REQUIRED. | | | | | | ANY WORK ON THE FIRE SPRINKLER SYSTEM, INCLUDING DEMO, | | | SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | 1A) SHEET A 501 - WITHIN THE LEGEND DIAMOND NOTE # 9 | | | INDICATES THE EXISTING FIRE SPRINKLERS TO REMAIN. | | | | | | THE DIAMOND # 9 COULD NOT BE FROUND IN ANY OF THE | | | CALL-OUTS SECTIONS. | | | | | | THOUGH EXISTING SPRINKLERS MAY REMAIN ABOVE THE | | | TRELLIS, THEY ARE NOT IDENTIFIED CORRECTLY, AND | | | SPRINKLER PROTECTION MAY BE REQUIRED TO EXTEND UNDER | | | THE TRELLIS | | | | | | PLEASE REVIEW AND CORRECT AND ADDRESS # 1 ABOVE. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-01 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-22 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-08-16 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-09 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-28 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-28 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-10-27 |
Time |
16:08 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-10-27 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
eshneide |
Date |
2021-08-16 |
Time |
16:13 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-08-16 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2021-08-16 16:14:50 | FAILED | | | | | | THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS | | | REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A | | | LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES | | | THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |