Plan Review Details - Permit 21070222
Plan Review Stops For Permit 21070222
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-09-15 Cont ID  
Sent By jwitmer Date 2021-09-15 Time 07:45 Rev Time 0.00
Received By jwitmer Date 2021-09-14 Time 17:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-15 Cont ID  
Sent By pvalenti Date 2021-10-15 Time 16:39 Rev Time 0.00
Received By pvalenti Date 2021-10-15 Time 06:53 Sent To  
Notes
2021-10-15 16:41:51PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 THE HANDICAPPED PARKING SPACE(SHOWN WITH DIMENSIONS,
 SIGN, & ACCESS AISLE) MUST BE SHOWN ON PLAN CLOSE TO
 MAIN ENTRY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-15 Cont ID  
Sent By jwitmer Date 2021-09-15 Time 09:47 Rev Time 0.00
Received By jwitmer Date 2021-09-14 Time 17:26 Sent To  
Notes
2021-09-15 09:47:19WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21070222
 ADD: 4806 S. DIXIE HWY.
 CONT: MAC ENTERPRISES INC.
 TEL: 561-840-0063
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 15TH/ 2021
 ACTION: DENIED
  
 1A) IT IS NOTED THIS PERMIT IS FOR INTERIOR
 RENOVATIONS, A VANILLA SHELL. THERE ARE QUESTIONS ABOUT
 THE ENTRANCE, ENTRY VESTIBULE BEING IN THE REAR OF THE
 BUILDING. LOOKING AT THE PROPERTY WITH GOOGLE MAPS IT
 APPEARS THERE ARE GATES IMPEDING ENTRY TO THE REAR
 ENTRANCE. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 1B) THE LIFE SAFETY PLAN DOES NOT INDICATE IF THE MAIN
 ENTRANCE, THE REAR ENTRANCE IS A ACCESSIBLE ENTRANCE.
 2020 FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 AND 303.3.
 WHERE CHANGES IN LEVEL ARE PERMITTED IN THE FLOOR OR
 GROUND SURFACES, THEY SHALL COMPLY WITH SECTION 303.
 SEE 303.1 & 303.2.
  
 2) THE LIFE SAFETY PLAN HAS A ROOM NAMED A KITCHENETTE.
 IN COMMERCIAL USE YOU CAN NOT HAVE EGRESS THROUGH A
 KITCHEN , STORAGE ROOM OR SPACE USED FOR SIMILAR
 PURPOSES.
  
 3) THE LIFE SAFETY PLAN FOR A BUSINESS OCCUPANCY THE
 OCCUPANT LOAD TABLE THE DESIGNER IS TAKING 100 GROSS
 AND 50 GROSS FOR THE OCCUPANT LOAD FACTOR. PLEASE NOTE
 IN THE 2020 FBC-BUILDING CODE THERE WAS A CHANGE FOR
 THE BUSINESS OCCUPANCY THE OCCUPANT LOAD FACTOR IS NOW
 150 GROSS. PLEASE UPDATE THE PLANS.
  
 4) THE LIFE SAFETY PLAN SHOWS A COUNTER AND SINK WITH
 UPPER CABINETS AND OR SHELVING, PLEASE PROVIDE A
 ELEVATION VIEW OF THIS AREA. SHOW COMPLIANCE WITH THE
 2020 FBC-ACCESSIBILITY CODE SECTIONS:
  
 4A) 2020 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 4B) 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED, SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED
 CLEAR FLOOR SPACE ON THE FLOOR PLAN.
  
 4C) 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY &
 DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE
 INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
 CONTACT.
  
 5) WHAT IS NOT KNOWN IF IN THE BREAK ROOM ELEVATION, IF
 THERE IS A MICROWAVE IN THE UPPER CABINETS. A MICROWAVE
 WILL NEED TO COMPLY WITH THE 2020 FBC-ACCESSIBILITY
 CODE:
  
 5A) 308 REACH RANGES:
 308.2 FORWARD REACH./ 308.2.1 UNOBSTRUCTED/ 308.2.2
 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 5B) 309 OPERABLE PARTS
 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE
 OR MORE OF THE REACH RANGES SPECIFIED IN 308.
 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH
 ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
 PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED
 TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N)
 MAXIMUM.
  
 6) SHEET A1.1 THE RESTROOM ELEVATIONS TOILET PAPER
 DISPENSERS. SEE THE 2020 ACCESS. CODE SECTION. 604.7.
 THE TOILET PAPER DISPENSER SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM TO 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-10-13 Cont ID  
Sent By jleahy Date 2021-10-13 Time 15:48 Rev Time 0.00
Received By jleahy Date 2021-10-13 Time 15:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By jleahy Date 2021-09-07 Time 15:49 Rev Time 0.00
Received By jleahy Date 2021-09-07 Time 15:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-08 Cont ID  
Sent By   Date 2021-10-08 Time   Rev Time 0.00
Received By bdolan Date 2021-10-08 Time 10:55 Sent To  
Notes
2021-10-08 10:55:16REVISION PASS FIRE.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By   Date 2021-09-07 Time   Rev Time 0.00
Received By bdolan Date 2021-09-07 Time 12:07 Sent To  
Notes
2021-09-07 12:13:17PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-15 Cont ID  
Sent By pvalenti Date 2021-10-15 Time 16:42 Rev Time 0.00
Received By pvalenti Date 2021-10-06 Time 06:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-16 Cont ID  
Sent By lcrespo Date 2021-09-16 Time 14:30 Rev Time 0.00
Received By lcrespo Date 2021-09-03 Time 09:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-10-06 Cont ID  
Sent By medwards Date 2021-10-06 Time 15:05 Rev Time 0.00
Received By medwards Date 2021-10-06 Time 15:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-09-08 Cont ID  
Sent By medwards Date 2021-09-08 Time 08:19 Rev Time 0.00
Received By medwards Date 2021-09-07 Time 06:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-10-15 Cont ID  
Sent By lcrespo Date 2021-10-15 Time 10:06 Rev Time 0.00
Received By lcrespo Date 2021-10-15 Time 09:37 Sent To  
Notes
2021-10-15 10:07:1510/15/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-16 Cont ID  
Sent By lcrespo Date 2021-09-16 Time 14:30 Rev Time 0.00
Received By lcrespo Date 2021-09-16 Time 13:09 Sent To  
Notes
2021-09-16 15:02:0309/16/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET A1.0;
 A. WOULD YOU PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE
 DRINKING FOUNTAIN AND BREAKROOM PER THE 2020 FBC ACC
 SEC. 606.2. 2 CLEAR FLOOR SPACE.
  
 B. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. WOULD YOU PLEASE MAKE A NOTE ON THIS SHEET?
  
 2. ON SHEET A1.1, DETAIL A;
  
 A. THE TOILET GRAB BAR SAYS 6 INCHES FROM THE WALL,
 WHICH IS NOT AN ACTUAL NUMBER AS THE TOILET IS 16
 INCHES TO 18 INCHES TO THE CENTER, AND THAT NUMBER MAY
 CONFUSE THE INSTALLER. WOULD YOU PLEASE CORRECT PER THE
 2020 FBC ACC SEC. 604.2 LOCATION AND WPB AMENDMENTS TO
 THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS? REFER TO G1.2 F.
  
 B. WOULD YOU PLEASE LABEL THE RESTROOM PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 C. ON DETAIL 1, THE 5'-0" FOR THE TURNING RADIUS IS NOT
 THE RIGHT LOCATION FOR THE MEN'S RESTROOM. WOULD YOU
 PLEASE CORRECT PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS?
  
 D. WATER CLOSET FLUSH CONTROL SHALL BE OPEN SIDE PER
 THE 2020 FBC ACC SEC. 604.9.5.
  
 E. SEATS OF WATER CLOSETS SHALL BE OPEN-FRONT TYPE PER
 2020 FBC P 425.3 WATER CLOSET SEATS.
  
 F. WOULD YOU PLEASE PROVIDE ELEVATIONS FOR THE
 ACCESSIBLE KITCHEN SINK PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. ON SHEET G1.2 DETAIL C, IT SHOWS THE VALVE AT 44"
 HANDICAP CAP WATER CLOSET FLUSH CONTROL SHALL BE HAND
 OPERATED OR AUTOMATIC AND SHALL BE 36" INCHES MAXIMUM
 ABOVE THE FINISH FLOOR PER THE 2020 FBC ACC SEC.
 604.9.5. IF YOU ARE USING TANK-TYPE WOULD YOU, PLEASE
 DELETE OR CORRECT DETAIL C PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 4. ON SHEET P0.1;
  
 A. IN THE SANITARY ISOMETRIC, THE TOILETS IS NOT DO NOT
 MATCH THE LAYOUT ON PAGE P2.1. WOULD YOU PLEASE CORRECT
 PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS?
  
 B. IN THE WATER ISOMETRIC, THE HOT WATER LINES LOOPED
 FOR THE RECIRCULATING SYSTEM ARE NOT IN A CONTINUOUS
 LOOP. THERE ARE REQUIREMENTS IN THE FLORIDA ENERGY CODE
 SEC. C404.6.1.
  
 C. IN THAT SAME DETAIL, A TABLE LIMITS THE DISTANCE
 BETWEEN THE SOURCE AND THE OUTLET. PLEASE REFER TO
 TABLE 405.5.1 FOR THE MAXIMUM ALLOWABLE PIPE LENGTH
 METHOD AND SIZE ACCORDANTLY.
  
 D. THE RECALCULATING PER MANUFACTURES SPECIFICATION AND
 MAINTENANCE MAY REQUIRE SHUT-OFF VALVES ON EACH SIDE OF
 THE RECALCULATING PUMP PER THE 2020 FBC SEC. 606.2
 LOCATION OF SHUTOFF VALVES.
  
 F. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125 PER THE 2020 FBC P
 419.5 WATER FOR PUBLIC HAND-WASHING FACILITIES.
  
 5. ON SHEET P2.1;
  
 A. THE CONDENSATE LINE SAYS IT IS DRAINING INTO THE
 ROOF DRAIN, AND THIS IS NOT PERMITTED TO DISCHARGE INTO
 THE CITY'S STORM SYSTEM PER CITY ORDINANCE CHAPTER 90,
 ARTICLE III, SEC.90-126 (B)(5). WOULD YOU PLEASE
 PROVIDE AN ALTERNATIVE SOURCE?
  
 PLEASE FEEL FREE TO CONTACT ME ON ANY OF THE COMMENTS
 BY PHONE OR ZOOM MEETING IF YOU LIKE.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-672
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-15 Cont ID  
Sent By lcrespo Date 2021-10-15 Time 10:07 Rev Time 0.00
Received By lcrespo Date 2021-10-15 Time 10:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By medwards Date 2021-09-07 Time 06:35 Rev Time 0.00
Received By medwards Date 2021-09-07 Time 06:35 Sent To  
Notes
***NONE***