| Plan Review Stops For Permit 21070167 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-28 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-28 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2021-09-28 12:53:08 | APPLICANT VERIFIED THAT THE ADDRESS IS 208 FERN ST AND | | | UPLOADED A NEW APPLICATION REFLECTING THE 208 FERN ST | | | ADDRESS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-08 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-08 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2021-09-08 16:53:23 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-07 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-07 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2021-07-07 16:08:22 | ST ANDREWS RESIDENCE HAS TWO BUILDINGS 208 FERN ST AND | | | 400 S OLIVE AVE. YOUR APPLICATION FORM STATES 205 FERN | | | ST. PLEASE UPDATE THE APPLICATION FORM TO REFLECT THE | | | CORRECT ADDRESS. PLEASE CONTACT [email protected] OR | | | 561-805-6659 IF YOU HAVE ANY QUESTIONS. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-07 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-07 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-13 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2021-09-13 07:58:17 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ASBESTOS REVIEW DENIED: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING | | | ASBESTOS REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-05 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-05 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2021-08-05 11:38:04 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-28 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-28 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-07 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-07 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2021-10-07 11:56:47 | BUILDING RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE OCCUPANT LOAD FOR THE GROUND FLOOR | | | COMMUNITY ROOM. SHOW THE ROOM SIZE AND THE CALCULATIONS | | | USED TO DETERMINE THE OCCUPANT LOAD - FBC 1004.4 | | | | | | 2) THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | | PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | | ATTACHED TO THE FLOORING) | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-13 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2021-09-13 09:47:46 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1) FBC B 803.11, PLEASE SHOW THE REQUIRED FIRE | | | CLASSIFICATION FOR THE WALL AND CEILING FINISHES. PLAN | | | SHEET A800.A. GENERAL NOTES REFER TO (IBC) CODE | | | SECTIONS. THE REQUIRED FIRE CLASSIFICATION NEEDS TO BE | | | ON THE FINISH SCHEDULES FOR WALL AND CEILING AREAS. | | | 2) FBC B 1004.4, PLEASE SHOW, UNDER DESIGN OCCUPANT | | | LOAD ON PLAN SHEET GN100, THE OCCUPANT LOAD FOR THE | | | 1STFLOOR COMMUNITY ROOM. | | | 3) DOUBLE DOOR SWING POSITON IN COMMUNITY ROOM. OK | | | 4) FBC B 107.2.1, PLEASE ADD NOTE, UNDER SCOPE OF WORK | | | ON PLAN SHEET GN100, NO FLOORING WILL BE REPLACED AND | | | REMOVE THE FLOORING TILE SECTIONS FROM TILE SCHEDULE ON | | | SHEET A800.A OR PROVIDE ON PLAN THE UNDERLAYMENT THAT | | | WILL BE USED FOR FLOORING REPLACEMENTINCLUDING THE TEST | | | REPORTS FOR SOUND AND FLAMESPREAD IN ACCORDANCE WITH | | | FBC B 1207.2, 1207.3, & 603.1. | | | 5) OK, AS DEFERRED SUBMITTAL HAS BEEN INDICATED ON | | | PLAN. | | | 6) FBC B 107.2.1, PLEASE PROVIDE THE, DESIGNER OF | | | RECORD REVIEW STAMP APPROVED, PRODUCT APPROVALS FOR THE | | | NEW EXTERIOR WINDOWS, DOORS, LOUVERS, AND ROOFING | | | SYSTEMS & MATERIALS. | | | 7) NOTE: ALL SHOP DRAWINGS AND PRODUCT APPROVALS MUST | | | BE REVIEW/APPROVED BY DESIGNER OF RECORD (ACKNOWLEDGED | | | ON RESPONSE SHEET). | | | 8) OK, THE CONSTRUCTION TYPE HAS BEEN ADDED TO PLAN | | | SHEET GN100. | | | 9) NOTE: WPB/FBC B 107.3.4.1, DEFERRED SUBMITTAL | | | REQUIREMENTS HAVE BEEN ACKNOWLEDGED BY ENGINEER JEREMY | | | M. CASE P.E. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-05 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-03 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2021-08-05 11:35:58 | BUILDING RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE SHOW THE REQUIRED FIRE CLASSIFICATION FOR THE | | | WALL AND CEILING FINISHES PER FBC 803.11 | | | 2) PLEASE SHOW THE OCCUPANT LOAD FOR THE GROUND FLOOR | | | COMMUNITY ROOM. FBC 1004.4 | | | 3) PLEASE SHOW THE COMMUNITY ROOM (DOUBLE DOORS) EGRESS | | | DOORS TO SWING OUT FBC 1010.1.2.1 DIRECTION OF SWING. | | | PIVOT OR SIDE-HINGED SWINGING DOORS SHALL SWING IN THE | | | DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA | | | CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS | | | 4) THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | | PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | | ATTACHED TO THE FLOORING) | | | | | | 5) PLEASE PROVIDE DRAWINGS FOR THE RAILING SYSTEM, | | | ALUMINUM CANOPY, ALUMINUM LATTICE, EXTERIOR ALUMINUM | | | WALL PANELS SHOWING COMPONENTS AND ATTACHMENTS TO | | | COMPLY WITH THE WIND LOADS PER FBC 1609 | | | 6) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS, | | | LOUVERS AND ROOFING SYSTEMS. | | | 7) ALL SHOP DRAWINGS AND PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD. | | | FBC WPB 107.2 | | | 8) CONSTRUCTION TYPE SHOWN SHOULD BE (I A) SEE FBC | | | CHAPTER 5 | | | 9) FBC WPB 107.3.4.1 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-10-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-02 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-09-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-09-21 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-08 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-08-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-02 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-23 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-29 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-10 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-23 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2021-07-27 11:10:42 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE INDICATIONS OF A FIRE SPRINKLER | | | INSTALLATION; HOWEVER, THE FS ARE NOT INDICATED IN | | | REQUIRED AREAS. | | | | | | PER NFPA 1 | | | | | | 11.8.3 EXTINGUISHING REQUIREMENTS. | | | 11.8.3.1* HIGH-RISE BUILDINGS SHALL BE PROTECTED | | | THROUGHOUT BY AN | | | APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH | | | SECTION 9.7. A SPRINKLER CONTROL VALVE AND A WATERFLOW | | | DEVICE SHALL BE | | | PROVIDED FOR EACH FLOOR. | | | A.11.8.3.1 WHERE AN OCCUPANCY CHAPTER (CHAPTERS 12 | | | THROUGH 42) PERMITS | | | THE OMISSION OF SPRINKLERS IN SPECIFIC SPACES, SUCH AS | | | SMALL BATHROOMS | | | AND CLOSETS IN RESIDENTIAL OCCUPANCIES, THE BUILDING IS | | | STILL | | | CONSIDERED TO BE PROTECTED THROUGHOUT FOR THE PURPOSES | | | OF 11.8.3.1. | | | | | | | | | PER NFPA 101 CH 31 EXISTING APARTMENT OCCUPANCIES | | | | | | 31.3.5.2* WHERE AN AUTOMATIC SPRINKLER SYSTEM IS | | | INSTALLED, EITHER FOR | | | TOTAL OR PARTIAL BUILDING COVERAGE, THE SYSTEM SHALL BE | | | INSTALLED IN ACCORDANCE | | | WITH SECTION 9.7, AS MODIFIED BY 31.3.5.3 AND 31.3.5.4. | | | IN BUILDINGS FOUR OR | | | FEWER STORIES IN HEIGHT AND NOT EXCEEDING 60 FT (18.3 | | | M) IN HEIGHT ABOVE | | | GRADE PLANE, SYSTEMS IN ACCORDANCE WITH NFPA 13R SHALL | | | BE PERMITTED. | | | | | | 31.3.5.12 HIGH-RISE BUILDING SPRINKLERS. | | | 31.3.5.12.1 ALL HIGH-RISE BUILDINGS, OTHER THAN THOSE | | | MEETING 31.3.5.12.2 | | | OR 31.3.5.12.3, SHALL BE PROTECTED THROUGHOUT BY AN | | | APPROVED, SUPERVISED | | | AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH 31.3.5.2. | | | | | | | | | ST. ANDREWS HAS NOT PROVIDED AN ELSS FOR THE | | | MODIFICATIONS TO THEIR FS SYSTEM. | | | THIS AHJ DOES NOT HAVE RECORD THAT THE RESIDENTS/OWNERS | | | HAVE OPTED OUT OF THE FLORIDA RETROFIT | | | REQUIRMENTS THRUS A FIRE SPRINKLER SYSTEM SHALL BE | | | INSTALLED. | | | | | | 31.3.5.12.3* AN AUTOMATIC SPRINKLER SYSTEM SHALL NOT BE | | | REQUIRED IN | | | BUILDINGS HAVING AN APPROVED, ENGINEERED LIFE SAFETY | | | SYSTEM IN ACCORDANCE | | | WITH 31.3.5.12.4. | | | | | | 31.3.5.12.4 WHERE REQUIRED BY 31.3.5.12.3, AN | | | ENGINEERED LIFE SAFETY | | | SYSTEM SHALL BE DEVELOPED BY A REGISTERED PROFESSIONAL | | | ENGINEER EXPERIENCED | | | IN FIRE AND LIFE SAFETY SYTEM DESIGN, SHALL BE APPROVED | | | BY THE | | | AUTHORITY HAVING JURISDICTION, AND SHALL INCLUDE ANY OR | | | ALL OF THE | | | FOLLOWING: | | | (1) PARTIAL AUTOMATIC SPRINKLER PROTECTION | | | (2) SMOKE DETECTION SYSTEMS | | | (3) SMOKE CONTROL SYSTEMS | | | (4) COMPARTMENTATION | | | (5) OTHER APPROVED SYSTEMS | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 2) ONLY ONE STAIR HAS AN INDICATION OF A STANDPIPE. | | | | | | PER NFPA 1 | | | | | | 11.8.3.2 HIGH-RISE BUILDINGS SHALL BE PROTECTED | | | THROUGHOUT BY A CLASS I | | | STANDPIPE SYSTEM IN ACCORDANCE WITH SECTION 9.10. | | | | | | 9.10 STANDPIPE SYSTEMS | | | 9.10.1 WHERE REQUIRED BY ANOTHER SECTION OF THIS CODE, | | | STANDPIPE AND | | | HOSE SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA | | | 14. | | | 9.10.2 WHERE STANDPIPE AND HOSE SYSTEMS ARE INSTALLED | | | IN COMBINATION | | | WITH AUTOMATIC SPRINKLER SYSTEMS, INSTALLATION SHALL BE | | | IN ACCORDANCE | | | WITH THE APPROPRIATE PROVISIONS ESTABLISHED BY NFPA 13 | | | AND NFPA 14. | | | | | | NFPA 14 | | | | | | 7.3.2* CLASS I SYSTEMS. CLASS I SYSTEMS SHALL BE | | | PROVIDED WITH | | | 21?2 IN. (65 MM) HOSE CONNECTIONS IN THE FOLLOWING | | | LOCATIONS: | | | (1) AT THE MAIN FLOOR LANDING IN EXIT STAIRWAYS | | | (2) ON EACH SIDE OF THE WALL ADJACENT TO THE EXIT | | | OPENINGS OF | | | HORIZONTAL EXITS | | | (3) IN OTHER THAN COVERED MALL BUILDINGS, IN EACH EXIT | | | PASSAGEWAY | | | AT THE ENTRANCE FROM THE BUILDING AREAS INTO THE | | | PASSAGEWAY | | | (4) IN COVERED MALL BUILDINGS, AT THE ENTRANCE TO EACH | | | EXIT | | | PASSAGEWAY OR EXIT CORRIDOR, AND AT THE INTERIOR SIDE | | | OF | | | PUBLIC ENTRANCES FROM THE EXTERIOR TO THE MALL | | | (5)*AT THE HIGHEST LANDING OF STAIRWAYS WITH STAIRWAY | | | ACCESS TO A | | | ROOF, OR ON ROOFS WITH A SLOPE OF LESS THAN 4 IN 12 | | | WHERE | | | STAIRWAYS DO NOT ACCESS THE ROOF | | | 7.3.2.1 HOSE CONNECTIONS SHALL BE PERMITTED TO BE | | | LOCATED AT | | | THE HIGHEST INTERMEDIATE LANDINGS BETWEEN FLOOR LEVELS | | | IN EXIT | | | STAIRWAYS WHERE REQUIRED BY THE AHJ. | | | 7.3.2.2* WHERE THE MOST REMOTE PORTION OF A | | | NONSPRINKLERED | | | FLOOR OR STORY IS LOCATED IN EXCESS OF 150 FT (45.7 M) | | | OF TRAVEL | | | DISTANCE FROM A HOSE CONNECTION IN OR ADJACENT TO A | | | REQUIRED | | | EXIT OR THE MOST REMOTE PORTION OF A SPRINKLERED FLOOR | | | OR STORY | | | IS LOCATED IN EXCESS OF 200 FT (61 M) OF TRAVEL | | | DISTANCE FROM A | | | HOSE CONNECTION IN OR ADJACENT TO A REQUIRED EXIT, | | | ADDITIONAL | | | HOSE CONNECTIONS SHALL BE PROVIDED, IN APPROVED | | | LOCATIONS, | | | WHERE REQUIRED BY THE LOCAL FIRE DEPARTMENT OR THE AHJ. | | | | | | PLEASE REVIEW AND PROVIDE A STANDPIPE IN EACH STAIRWELL | | | OR PROVIDE APPLICABLE DETAILS IN COMPLIANCE WITH CODE. | | | | | | | | | | | | 3) SHOULD IT BE INTENDED FOR THE BUILDING TO REMIAN | | | OCCUPIED, THERE ARE NO LIFE SAFETY PLAN SHEETS | | | INDICATING HOW THE EXITS/EXIT ROUTES WILL BE MAINTAINED | | | DURING CONSTRUCTION. | | | | | | ADDITIONALLY, WITH ALL THE EXTERIOR WORK HOW WILL THE | | | AREA BE PROTECTED FROM FALLING OR ACCUMULATED | | | CONSTRUCTION DEBRIS. | | | | | | PER NFPA 1 | | | | | | 4.6.10 CONSTRUCTION, REPAIR, AND IMPROVEMENT | | | OPERATIONS. | | | 4.6.10.1* BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE | | | PERMITTED TO BE | | | OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS, OR | | | ADDITIONS ONLY WHERE | | | REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION | | | FEATURES ARE IN | | | PLACE AND CONTINUOUSLY MAINTAINED FOR THE PORTION | | | OCCUPIED OR WHERE | | | ALTERNATIVE LIFE SAFETY MEASURES ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION | | | ARE IN PLACE. | | | | | | 4.6.10.2 WHERE REQUIRED BY CHAPTERS 11 THROUGH 43, | | | CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS SHALL COMPLY WITH | | | NFPA 241 | | | | | | 4.6.10.3* IN BUILDINGS UNDER CONSTRUCTION, ADEQUATE | | | ESCAPE FACILITIES | | | SHALL BE MAINTAINED AT ALL TIMES FOR THE USE OF | | | CONSTRUCTION WORKERS. | | | ESCAPE FACILITIES SHALL CONSIST OF DOORS, WALKWAYS, | | | STAIRS, RAMPS, FIRE | | | ESCAPES, LADDERS, OR OTHER APPROVED MEANS OR DEVICES | | | ARRANGED IN | | | ACCORDANCE WITH THE GENERAL PRINCIPLES OF THE CODE | | | INSOFAR AS THEY CAN | | | REASONABLY BE APPLIED TO BUILDINGS UNDER CONSTRUCTION. | | | | | | PLEASE PROVIDE SPECIFIC DETAILS PROVIDING LIFE SAFETY. | | | | | | | | | | | | 4) THE ELECTRICAL PLAN SHEETS INDICATE FIRE ALARM | | | EQUIPMENT. | | | | | | ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEGEMENT. | | | | | | | | | | | | 5) ELECTRICAL SHEETS - THERE ARE NO OF SMOKE ALARMS | | | WITHIN THE INDIVIDUAL UNIT. | | | | | | PER NFPA 101 CH 31 | | | | | | 31.3.4.5 SMOKE ALARMS. | | | 31.3.4.5.1* IN BUILDINGS OTHER THAN THOSE EQUIPPED | | | THROUGHOUT WITH AN | | | EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM, | | | SMOKE ALARMS | | | SHALL BE INSTALLED IN ACCORDANCE WITH 9.6.2.10, AS | | | MODIFIED BY 31.3.4.5.2, | | | OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE VICINITY | | | OF THE BEDROOMS | | | AND ON ALL LEVELS OF THE DWELLING UNIT, INCLUDING | | | BASEMENTS. | | | | | | 31.3.4.5.3 IN BUILDINGS OTHER THAN THOSE EQUIPPED | | | THROUGHOUT WITH AN | | | EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM OR | | | A COMPLETE, | | | SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE | | | WITH 31.3.5, SMOKE | | | ALARMS SHALL BE INSTALLED IN EVERY SLEEPING AREA IN | | | ACCORDANCE WITH | | | 9.6.2.10, AS MODIFIED BY 31.3.4.5.4. | | | 31.3.4.5.4 SMOKE ALARMS REQUIRED BY 31.3.4.5.3 SHALL BE | | | PERMITTED TO | | | BE BATTERY POWERED. | | | | | | 9.6.2.10.1 WHERE REQUIRED BY ANOTHER SECTION OF THIS | | | CODE, SINGLESTATION | | | AND MULTIPLE-STATION SMOKE ALARMS SHALL BE IN | | | ACCORDANCE WITH | | | NFPA 72 UNLESS OTHERWISE PROVIDED IN 9.6.2.10.3, | | | 9.6.2.10.4, 9.6.2.10.6, | | | OR 9.6.2.10.7. | | | 9.6.2.10.2 WHERE AUTOMATIC SMOKE DETECTION IS REQUIRED | | | BY CHAPTERS 11 | | | THROUGH 43, SMOKE ALARMS SHALL NOT BE USED AS A | | | SUBSTITUTE. | | | 9.6.2.10.3* THE INTERCONNECTION OF SMOKE ALARMS SHALL | | | APPLY ONLY TO | | | NEW CONSTRUCTION AS PROVIDED IN 9.6.2.10.9. | | | | | | SHOULD IT BE INTENDED TO PROVIDE NEW SMOKE ALARMS IN | | | ALL THE UNITS THEN INTERCONNECTION WOULD APPLY. | | | | | | 9.6.2.10.9* IN NEW CONSTRUCTION, WHERE TWO OR MORE | | | SMOKE ALARMS ARE | | | REQUIRED WITHIN A DWELLING UNIT, SUITE OF ROOMS, OR | | | SIMILAR AREA, THEY | | | SHALL BE ARRANGED SO THAT OPERATION OF ANY SMOKE ALARM | | | SHALL CAUSE THE | | | ALARM IN ALL SMOKE ALARMS WITHIN THE DWELLING UNIT, | | | SUITE OF ROOMS, OR | | | SIMILAR AREA TO SOUND, UNLESS OTHERWISE PERMITTED BY | | | ONE OF THE | | | FOLLOWING: | | | (1) THE REQUIREMENT OF 9.6.2.10.9 SHALL NOT APPLY WHERE | | | PERMITTED BY | | | ANOTHER SECTION OF THIS CODE. | | | (2) THE REQUIREMENT OF 9.6.2.10.9 SHALL NOT APPLY TO | | | CONFIGURATIONS | | | THAT PROVIDE EQUIVALENT DISTRIBUTION OF THE ALARM | | | SIGNAL. | | | | | | PLEASE REVIEW AND CORRECT OR PROVIDE SPECIFIC DETAILS | | | AND CODE REFERENCES. | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-14 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-13 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2021-10-14 12:33:15 | THE ARCHITECT OF RECORD HAS REQUESTED GAS TO BE UNDER A | | | SEPARATE PERMIT. COMPLETE PLANS AND SPECIFICATIONS | | | SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-23 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-22 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2021-09-23 13:58:00 | 2ND REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21070167 | | | 8/3/2021 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN | | | CAPS FOR FURTHER CLARIFICATIONE | | | | | | 1) FAILED. P201: PLEASE INCLUDE THE WATER HEATER | | | EFFICIENCY RATINGS IN THE SCHEDULE- TABLE C404.1 FBC | | | EC. NOT PROVIDED. RATINGS CAN BE DEFERRED AND VERIFIED | | | WITH PRODUCT SUBMITTAL- SEE COMMENT #2 BELOW. | | | | | | 2) FAILED. P201: SUBMIT MANUFACTURER'S SPECIFICATIONS | | | AND INSTALLATION MANUAL FOR THE NEW WATER HEATERS- | | | SECTION 624.1 FBC FG. NOT PROVIDED. THE SPECIFICATIONS | | | AND MANUAL MAY BE DEFERRED AND INCLUDED IN A LIST OF | | | DEFERRED SUBMITTALS ON THE PLAN- SECTION 107.3.4.1 WPB. | | | | | | 2) FAILED. P106: PROVIDE A GAS PIPING PLAN AND RISER | | | DRAWING SHOWING COMPLIANCE WITH THE FBC FG AND SECTION | | | 107.3.5.15 WPB. | | | | | | B) FAILED. TYPE OF GAS- NATURAL OR LP AND SYSTEM | | | PRESSURE. TYPE OF GAS NOT PROVIDED. | | | | | | C) FAILED. TOTAL BTU LOAD AND WATER HEATER BTU LOADS. | | | LOADS NOT PROVIDED. | | | | | | D) FAILED. TYPES AND SIZES OF GAS PIPING. TYPE OF | | | PIPING NOT PROVIDED. | | | | | | G) FAILED. LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND | | | PIPE UNIONS. PIPE UNIONS NOT PROVIDED. PLEASE INDICATE | | | THE SELECTED MAKE AND MODEL NUMBER OF THE REGULATORS, | | | AND SUBMIT MARKED UP OR HIGHLIGHTED SPECS SHOWING THE | | | SELECTED MODEL, THE INPUT AND OUTPUT PIPE SIZES AND | | | PRESSURES- SECTION 410.2 FBC FG. PROVIDE A REGULATOR | | | AND RELIEF VALVE VENTING PLAN AND DIAGRAM IN ACCORDANCE | | | WITH SECTION 5.3- 5.3.2.1 NFPA 37, UNLESS THE SPECS | | | SHOW COMPLIANCE WITH SECTION 5.3.1.2 (ITEMS 1-4). | | | | | | I) FAILED. PIPE SIZING TABLES FOR ALL NEW PIPING | | | INSTALLATIONS. NOT PROVIDED. | | | | | | 3) FAILED. INDICATE HOW COMBUSTION AIR IS BEING | | | PROVIDED TO THE WATER HEATERS AND PROVIDE CALCULATIONS- | | | SECTION 304.1 FBC FG. NOT PROVIDED ON PLAN. THE | | | NARRATIVE FROM THE ENGINEER PROVIDES INFORMATION THAT | | | MUST BE PLACED ON THE PLAN. REFERENCE IS ALSO MADE TO | | | THE WH MANUAL WHICH HAS NOT BEEN PROVIDED. AS | | | PREVIOUSLY NOTE THE SPECS AND MANUAL MAY BE DEFERRED. | | | PLEASE REFER TO SECTION 304.6.2 FBC FG FOR COMBUSTION | | | AIR OPENING REQUIRMENTS AND PROVIDE INFORMATION AND/OR | | | DETAILS ON THE PLAN. | | | | | | 4) FAILED. PROVIDE A VENTING DIAGRAM IN COMPLIANCE WITH | | | SECTION 624.1 AND 503.3.2 FBC FG. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE VENT. THE ENGINEER'S NARRATIVE | | | REFRENCES THE MANUAL WHICH HAS NOT BEEN SUBMITTED. | | | PLEASE REFER TO SECTION 502.1 FBC FG AND INDICATE THE | | | TYPE OF VENTING SYSTEM TO BE INSTALLED BASED ON THE | | | CATEGORY OF THE WATER HEATERS- I, II, II, OR IV. | | | PROVIDE A COMPLETE VENTING PLAN INDICATING THE TYPE OF | | | MATERIAL, VENT RUN LENGTHS AND TERMINATION LOCATIONS-, | | | 502, AND 503 FBC FG. PLEASE INCLUDE VENTING HANGING AND | | | SUPPORT DETAILS- SECTION 503.6.11. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-08-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-08-03 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-08-03 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2021-08-03 18:08:02 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21070167 | | | 8/3/2021 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P201: PLEASE INCLUDE THE WATER HEATER EFFICIENCY | | | RATINGS IN THE SCHEDULE- TABLE C404.1 FBC EC. | | | | | | 2) P201: SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION MANUAL FOR THE NEW WATER HEATERS- SECTION | | | 624.1 FBC FG. | | | | | | 3) PD106 & P106: PLEASE ADD A NOTE OR REVISE THE NOTES | | | TO CLARIFY IF THE WATER HEATERS ARE BEING REPLACED IN | | | THE EXACT SAME LOCATIONS OR BEING RELOCATED- SECTION | | | 107.2.1 WPB. | | | | | | 2) P106: PROVIDE A GAS PIPING PLAN AND RISER DRAWING | | | SHOWING COMPLIANCE WITH THE FBC FG AND SECTION | | | 107.3.5.15 WPB. PLEASE SHOW: | | | | | | A) THE POINT OF CONNECTION TO THE EXISTING GAS PIPING | | | SYSTEM. | | | | | | B) TYPE OF GAS- NATURAL OR LP AND SYSTEM PRESSURE. | | | | | | C) TOTAL BTU LOAD AND WATER HEATER BTU LOADS. | | | | | | D) TYPES AND SIZES OF GAS PIPING. | | | | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | | | | H) INLET AND OUTLET PRESSURES AT REGULATORS. | | | | | | I) PIPE SIZING TABLES FOR ALL NEW PIPING INSTALLATIONS. | | | | | | 3) INDICATE HOW COMBUSTION AIR IS BEING PROVIDED TO THE | | | WATER HEATERS AND PROVIDE CALCULATIONS- SECTION 304.1 | | | FBC FG. | | | | | | 4) PROVIDE A VENTING DIAGRAM IN COMPLIANCE WITH SECTION | | | 624.1 AND 503.3.2 FBC FG. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE VENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-01 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-01 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-10-26 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-09-28 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-09-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-07 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-17 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-21 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-05 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-05 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2021-08-05 11:40:22 | NO CHANGE IN OCCUPANCY CLASSIFICATION - NO BUILDING | | | ADDITION - IMPACT FEES NOT REQUIRED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-02 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-02 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-20 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-08 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-22 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-22 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2021-07-22 08:44:11 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21070167 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE INFORMATION ON ALL OF THE EXISTING | | | MECHANICAL SYSTEMS. ARE THE NEW SYSTEMS A LIKE FOR LIKE | | | CHANGE OUT? FBC 107.2.1 | | | | | | 2) PLEASE SHOW THE EXISTING CONDENSATE DRAIN FOR THE | | | NEW UNITS TO DRAIN TO. FBC M 307 | | | | | | 3) SHEET M304: MD-O66 IS FOR A KITCHEN ROOF EXHAUST FAN | | | DETAIL, PLEASE REFERENCE WHERE THE KITCHEN IS LOCATED | | | FOR THIS PROJECT. FBC 107.2.1 | | | | | | 4) SHEET M101: PLEASE PROVIDE OUTDOOR AIR CALCULATIONS | | | FOR THE NEW GROUND FLOOR LAYOUT. IT SHOULD BE FOR EACH | | | USE OF SPACE ON THE GROUND FLOOR. FBC M 403.3.1.1 AND | | | TABLE 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-28 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-28 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2021-10-28 09:15:09 | NOT A SUBSTANTIAL IMPROVEMENT | | | | | | PALM BEACH COUNTY FLOOD ZONE MAP SHOWS BUILDING IN A | | | FLOOD ZONE AE-6 | | | APPRAISAL SHOWS BUILDING VALUE OF 17,904,700 / 2 = | | | 8,952,350.00 | | | JOB VALUE OF 7,600,000.00 | | | 5YR CUMULATIVE = 0 | | | | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-07 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-07 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2021-10-07 12:43:59 | APPRAISAL PROVIDED DOESN'T APPEAR TO SHOW THE "BUILDING | | | ONLY" MARKET VALUE (NO LAND) | | | | | | PALM BEACH COUNTY FLOOD ZONE MAP SHOWS BUILDING IN A | | | FLOOD ZONE AE-6 | | | PALM BEACH COUNTY PROPERTY APPRAISER SHOWS BUILDING | | | VALUE OF 11,294,803.00 / 2 = 5,647,401.00 | | | JOB VALUE OF 7,600,000.00 | | | JOB IS A SUBSTANTIAL IMPROVEMENT - FBC EXISTING | | | BUILDING 701.3 | | | AS A SUBSTANTIAL IMPROVEMENT THE BUILDINGS "LOWEST | | | FLOOR" ELEVATION WILL NEED TO BE AT OR ABOVE 8.00 NAVD | | | - CITY ORDINANCE NO. 4729-17 | | | PLEASE PROVIDE A SURVEY OR ELEVATION CERTIFICATE USING | | | THE LATEST FIRM THAT SHOWS THE BUILDINGS LOWEST FLOOR. | | | AN INDEPENDENT APPRAISAL CAN BE PROVIDED SHOWING THE | | | BUILDING ONLY AS IS VALUE. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-13 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2021-09-13 07:36:35 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | NFIP REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE CLARIFY AND SHOW THE APPRAISED | | | CASH VALUE. THE LAST REVIEW SHOWED THE VALUE TO BE | | | $11,294,803.00 PER THE PALM BEACH COUNTY APPRAISER'S | | | SITE. IF THAT VALUE IS DIFFERENT, PLEASE SHOW WHAT THE | | | APPRAISED CASH VALUE OF THE BUILDING IS. PLEASE NOTE | | | THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY RESULT IN NEW | | | PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-05 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-05 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2021-08-05 12:33:04 | PALM BEACH COUNTY FLOOD ZONE MAP SHOWS BUILDING IN A | | | FLOOD ZONE AE-6 | | | PALM BEACH COUNTY PROPERTY APPRAISER SHOWS BUILDING | | | VALUE OF 11,294,803.00 / 2 = 5,647,401.00 | | | JOB VALUE OF 7,600,000.00 | | | JOB IS A SUBSTANTIAL IMPROVEMENT - FBC EXISTING | | | BUILDING 701.3 | | | AS A SUBSTANTIAL IMPROVEMENT THE BUILDINGS "LOWEST | | | FLOOR" ELEVATION WILL NEED TO BE AT OR ABOVE 8.00 NAVD | | | - CITY ORDINANCE NO. 4729-17 | | | PLEASE PROVIDE A SURVEY OR ELEVATION CERTIFICATE USING | | | THE LATEST FIRM THAT SHOWS THE BUILDINGS LOWEST FLOOR. | | | AN INDEPENDENT APPRAISAL CAN BE PROVIDED SHOWING THE | | | BUILDING ONLY AS IS VALUE. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-28 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-27 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-14 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-13 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2021-10-14 12:25:12 | 3RD REVIEW FBC-2020 PLUMBING | | | PERMIT- 21070167 | | | 10/13/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIE. | | | | | | 1) SHEET GN100: THE REVISED PLAN SHEET NOW ESTABLISHES | | | THE BASIS OF DESIGN FOR THE ACCESSIBLE DWELLING UNITS | | | IS THE 2009 ICC/ANSI A117 ACCESSIBLE AND USABLE | | | BUILDINGS AND FACILITIES STANDARD. TYPE A UNITS ARE | | | SPECIFIED. PLEASE REVIEW SHEETS GN102, GN103, A805 & | | | A806 AND PROVIDE THE FOLLOWING MISSSING DETAILS PER THE | | | STANDARD: | | | | | | A) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 1003.11.7.4. | | | B) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTIONS & FIGS. 604.5.1, | | | 604.5.2. PLEASE CORRECT REAR GRAB BARS ON SHEETS GN102 | | | & GN103 AND PROVIDE COMPLETE DETAILS ON SHEETS A805 & | | | A806. | | | C) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE | | | FROM THE FINISHED FLOOR- SECTIONS 1003.11.5 & 606.3. | | | D) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | | THE REFLECTIVE SURFACES- SECTION 1003.11.6. THE DETAIL | | | DOES NOT INDICATE REFLECTIVE SURFACE. | | | E) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS ? | | | SECTION 1003.11.7.5. | | | F) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.10.7. | | | G) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTIONS | | | 606.2, 306.2, 306.3 AND FIG. 306.3 | | | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE ACCESSIBLE SHOWER- SECTION & FIG. 608.3.2. | | | TO HELP EXPEDITE REVIEW AND INSPECTION OF THE GRAB | | | BARS, PLEASE PROVIDE CONSISTENT LENGTH AND SPACING | | | MEASUREMENTS ON THE PLANS AND INDICATE THE HEIGHT | | | MEASUREMENTS ARE TO THE TOPS OF THE GRIPPING SURFACES. | | | I) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE | | | SHOWER- SECTION AND FIG. 608.5.2. THE ELEVATION | | | DRAWINGS SHOW ONE CONTROL VALVE ABOVE THE 48-INCH | | | MAXIMUM HEIGHT. | | | | | | 2) GN100, A102: THE PLANS INDICATE HVI UNITS WILL BE | | | INSTALLED ON THE 2ND-5TH FLOORS. PLEASE INDICATE WHICH | | | CODE OR STANDARD IS THE BASIS OF DESIGN FOR THESE UNITS | | | AND PROVIDE COMPLIANCE DRAWINGS AND DETAILS- SECTION | | | 107.2.1 WPB. | | | | | | 3) D101B, D201.B: THE SHEETS ARE IN CONFLICT REGARDING | | | THE TOILET COMPARTMENTS. IT APPEARS D201B NEEDS TO BE | | | CORRECTED. | | | | | | 4) SHEETS A102, A103, A104, A105: TO HELP EXPEDITE PLAN | | | REVIEW, CONSTRUCTION, AND INSPECTION OF THE RENOVATED | | | DWELLING UNITS, PLEASE PROVIDE REFERENCE NOTES OR | | | TARGETS INDICATING ON WHICH SHEETS THE ENLARGED FLOOR | | | PLANS ARE LOCATED- SECTION 107.2.1 WPB. | | | | | | 5) SHEETS A101A & A814: THE KNEE AND TOE CLEARANCES FOR | | | THE LOUNGE SINK SHALL BE IN COMPLIANCE WITH SECTIONS | | | 606.2, 306.2, & 306.3 FBC ACC. | | | | | | 6) A101, A101B, A825: MISSING ACCESSIBILITY DETAIL PER | | | THE FBC ACC: | | | | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SECTION 606.2. | | | B) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE | | | WALLS- SECTION 604.2. | | | C) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | D) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604.5.1 & 604.5.2. | | | E) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 606.2, 306.2, & 306.3 FBC ACC. | | | F) HEIGHT AND DEPTH OF THE URINAL- SECTION 605.2. | | | G) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | URINAL- SECTION 605.3 | | | H) PLEASE PROVIDE THE DIMENSIONS OF THE EXISTING TOILET | | | COMPARTMENTS TO VERIFY COMPLIANCE WITH SECTION 604.8.1. | | | I) PLEASE NOTE THAT ACCESSIBLE TOILET COMPARTMENT DOORS | | | SHALL NOT SWING INTO THE MINIMUM REQUIRED COMPARTMENT | | | AREA, DOORS SHALL BE SELF-CLOSING, AND PULLS PROVIDED | | | ON BOTH SIDES- 604.8.1.2. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-23 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-22 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2021-09-23 13:03:07 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 21070167 | | | 9/23/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES FOR | | | FURTHER CLARIFICATION. | | | | | | 2) FAILED. GN100: PLEASE PROVIDE A LIST OF DWELLING | | | UNITS, THE UNIT FLOOR LEVELS, AND COMMON AREAS THAT | | | WILL BE ALTERED AND IMPROVED IN ACCORDANCE WITH THE | | | CHOSEN ACCESSIBILITY STANDARD. INDICATE WHICH | | | ADMINISTRATIVE AUTHORITY HAS DETERMINED THE TYPE A | | | DESIGN TO BE USED AND THE NUMBER OF DWELLING UNITS TO | | | BE REMODELED. PLEASE CLARIFY HOW THE 5% NUMBER OF UNITS | | | TO BE CONVERTED TO TYPE A WAS DETERMINED-UNDER WHICH | | | ADMISINSTRATIVE AUTHORITY- SECTION 201 2009 ICC/ANSI | | | A117. | | | | | | 4) FAILED. GN102 & A805- 2009 ICC/ANSI A117: THE | | | REVISED SHEET INDICATES ADA TYPE 5 DESIGN. FOR | | | CLARIFICATION PLEASE INDICATE TYPE A OR B, 1BEDROOM OR | | | EFFICIENCY FOR ALL FLOOR PLAN DRAWINGS A802- A806. | | | PLEASE NOTE THERE IS NO CORRELATIING SCHEDULE FOR | | | NUMBERED TYPE UNITS 2-6- SECTION 107.2.1 WPB. | | | | | | E) FAILED. THE CONTROLS AND HAND SHOWER SHALL BE | | | LOCATED ON THE BACK WALL OF THE SHOWER ABOVE THE GRAB | | | BAR, 48 INCHES MAXIMUM ABOVE THE SHOWER FLOOR AND 16 | | | INCHES MINIMUM AND 27 INCHES MAXIMUM FROM THE END WALL | | | BEHIND THE SET- SECTION AND FIGURE 608.4.2. THE | | | ELEVATION 5 DETAIL ON A805 SHOWS CONTROLS AT (5FT. | | | 10-5/8-INCHES) HOWEVER MAXIMUM ALLOWED IS 48 INCHES. | | | | | | F) FAILED. THE HORIZONTAL GRAB BARS SHALL BE INSTALLED | | | 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE | | | FINISHED BATHROOM FLOOR AND SHOWER FLOOR TO THE TOPS OF | | | THE GRIPPING SURFACES- 609.4. DETAILS 5 & 6 ON A805- | | | THE MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB | | | BARS. | | | | | | H) FAILED. PROVIDE DETAILS FOR THE KITCHEN SINK REMOVAL | | | CABINET INDICATING COMPLIANCE WITH SECTION 1003.12.4.1 | | | ITEMS 1 & 2 (A, B, & C). SHEET GN101: SEE FIGURES | | | C606.2(A), C306.1(B), & C306.1 (C) AND CORRECT DETAIL | | | 20 TO THE MIN. 17 INCH AND MAX 25-INCH KNEE AND TOE | | | CLEARANCE DIMENSIONS. PLEASE PLACE THE DIMENSIONS IN | | | THE CORRECT LOCATION BELOW THE SINK. | | | | | | NEW COMMENT: INDICATE THE HEIGHTS OF THE MIRROR ARE | | | FROM THE FINISHED FLOORS TO THE REFLECTIVE SURFACE- | | | SECTION 603.3. | | | | | | 5) FAILED. GN103 & A806: 2009 ICC/ANSI A117: THE | | | REVISED SHEET INDICATES ADA TYPE 6 DESIGN. FOR | | | CLARIFICATION PLEASE INDICATE TYPE A OR B, 1BEDROOM OR | | | EFFICIENCY FOR ALL FLOOR PLAN DRAWINGS A802- A806. | | | PLEASE NOTE THERE IS NO CORRELATIING SCHEDULE FOR | | | NUMBERED TYPE UNITS 2-6- SECTION 107.2.1 WPB. | | | | | | E) FAILED. THE CONTROLS AND HAND SHOWER SHALL BE | | | LOCATED ON THE BACK WALL OF THE SHOWER ABOVE THE GRAB | | | BAR, 48 INCHES MAXIMUM ABOVE THE SHOWER FLOOR AND 16 | | | INCHES MINIMUM AND 27 INCHES MAXIMUM FROM THE END WALL | | | BEHIND THE SET- SECTION AND FIGURE 608.4.2. THE | | | ELEVATION 5 DETAIL ON A806 SHOWS CONTROLS AT (5FT. | | | 10-5/8-INCHES) HOWEVER MAXIMUM ALLOWED IS 48 INCHES | | | | | | F) FAILED. THE HORIZONTAL GRAB BARS SHALL BE INSTALLED | | | 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE | | | FINISHED BATHROOM FLOOR AND SHOWER FLOOR TO THE TOPS OF | | | THE GRIPPING SURFACES- 609.4. DETAILS 5 & 6 ON A806- | | | THE MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB | | | BARS. | | | | | | H) FAILED. PROVIDE DETAILS FOR THE KITCHEN SINK REMOVAL | | | CABINET INDICATING COMPLIANCE WITH SECTION 1003.12.4.1 | | | ITEMS 1 & 2 (A, B, & C). SHEET GN101: SEE FIGURES | | | C606.2(A), C306.1(B), & C306.1 (C) AND CORRECT DETAIL | | | 20 TO THE MIN. 17 INCH AND MAX 25-INCH KNEE AND TOE | | | CLEARANCE DIMENSIONS. PLEASE PLACE THE DIMENSIONS IN | | | THE CORRECT LOCATION BELOW THE SINK. PLEASE NOTE THE | | | ARCHIITECT?S RESPONSE TO THIS COMMENTS REFERS TO SHEETS | | | A902 & A903 WHICH HAVE NOT INCLUDED IN THE PLAN SETS. | | | | | | NEW COMMENT: INDICATE THE HEIGHTS OF THE MIRROR ARE | | | FROM THE FINISHED FLOORS TO THE REFLECTIVE SURFACE- | | | SECTION 603.3. | | | | | | 7) FAILED. A101.B: PROVIDE ENLARGED MEN'S AND WOMEN'S | | | BATHROOM DRAWINGS INDICATING PLUMBING FIXTURE | | | INSTALLATION COMPLIANCE WITH THE FBC ACCESSIBILITY | | | CODE- 2020. BASED ON THE PLANS IT APPEARS THESE | | | BATHROOMS ARE FOR BOTH PRIVATE AND PUBLIC USE. PLEASE | | | SEE SECTION 213.3 AND PROVIDE DRAWINGS AND DETAILS IN | | | COMPLIANCE WITH THE FBC ACC. PLEASE ADD CODE DATA TO | | | SHEET A101, A101A, A1018- FBC ACCESSIBILITY- 2020 7TH | | | EDITION. THE PLANS ARE INDICATING NON-COMPLIANCE FOR | | | THE MEN'S AND WOMEN'S TOILET COMPARTMENTS WHICH ARE | | | EACH REQUIRED TO CONTAIN AN ACCESSIBLE LAVATORY- | | | SECTION 213.3.1, 604.8.1, & 604.8.6 FBC ACC. THE PLANS | | | SHOW DEMOLITION OF THE EXISTING COMPARTMENTS WHICH | | | INDICATES NEW CONSTRUCTION COMPARTMENTS CAN BE | | | CONSTRUCTED AT THIS TIME TO MEET THE CODE. PLEASE REFER | | | TO SECTION 202.3 FBC ACC FOR ADDITIONAL ADVISORY | | | INFORMATION. PLEASE ALSO PROVIDE PLUMBING FIXTURE | | | CALCULATIONS FOR THE GROUND FLOOR BASED ON TABLE 403.1 | | | FBC P. PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED | | | AND PROVIDED NUMBER OF FIXTURES. | | | | | | A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE WATER CLOSETS- SECTION 604.3. PENDING PLAN | | | CORRECTIONS. | | | | | | B) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE LAVATORIES- SECTION 606.2. PENDING PLAN | | | CORRECTIONS. | | | | | | C) FAILED. TURNING SPACE DIAMETERS- SECTION 304.3. | | | SHEET A825- NOT PROVIDED IN COMPARTMENTS. | | | | | | D) FAILED. CENTERLINES OF THE WATER CLOSETS FROM THE | | | SIDE WALLS- SECTION 604.2. SHEET A825- NOT PROVIDED. | | | | | | E) NEW COMMENT- REFER TO SECTION 604.8.1.2 FBC ACC AND | | | VERIFY THE TOILET COMPARTMENT DOORS WILL BE SELF | | | CLOSING. | | | | | | F) NEW COMMENT- THE DOOR FOR THE MEN?S TOILET | | | COMPARTMENT SHALL NOT SWING INTO THE CLEAR FLOOR SPACE | | | REQUIRED FOR THE ACCESSIBLE URINAL- SECTION 603.2.3 FBC | | | ACC. | | | | | | 12) FAILED. P301: PROVIDE UL TESTED AND APPROVED | | | FIRESTOPPING ASSEMBLY DETAILS FOR PIPE PENETRATIONS ON | | | THE PLAN- SECTION 315.1 FBC P AND SECTION 714.4.1.2 FBC | | | B. THE DETAIL PROVIDED DOES NOT MEET COMPLIANCE. THE | | | DETAIL IS NOT A UL ASSEMBLY. THE ASSEMBLY MAY BE | | | DEFERRED AND INCLUDED IN A LIST OF DEFERRED SUBMITTALS | | | ON THE PLAN- SECTION 107.3.4.1 WPB. | | | | | | 13) FAILED. P401: PROVIDE CAST IRON PIPE AND FITTING | | | SPECIFICATIONS IN COMPLIANCE WITH SECTION 303.5 P. | | | | | | CAST-IRON SOIL PIPES AND FITTINGS, AND THE COUPLINGS | | | USED TO JOIN THESE PRODUCTS TOGETHER, SHALL BE | | | THIRD-PARTY LISTED AND LABELED. THIRD-PARTY CERTIFIERS | | | OR INSPECTORS SHALL COMPLY WITH THE MINIMUM INSPECTION | | | REQUIREMENTS OF ANNEX A OR ANNEX A1 OF THE ASTM AND | | | CISPI PRODUCT STANDARDS INDICATED IN THE CODE FOR SUCH | | | PRODUCTS. NOT PROVIDED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-08-03 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-08-02 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2021-08-03 17:20:37 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21070167 | | | 8/3/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET GN100: THE LIST OF CODES USED IN THE DESIGN | | | INCLUDE BOTH THE FBC ACCESSIBILITY 7TH EDITION 2020 AND | | | THE 2017 ICC/ANSI A117 WHICH ARE TWO SEPARATE CODE | | | STANDARDS. PLEASE NOTE THAT SECTION 806.1 FBC EX | | | REQUIRES ALTERATIONS TO COMPLY WITH THE PROVISIONS OF | | | THE FBC ACC. PLEASE CHOOSE ONE CODE OR THE OTHER AND | | | UPDATE ALL CODE REFERENCES SHOWN ON OTHER PLAN SHEETS. | | | IF THE INTENTION IS TO MEET FAIR HOUSING DESIGN | | | GUIDELINES, PLEASE NOTE THAT THE CURRENT SAFE HARBOR | | | FOR COMPLIANCE USED IS THE 2009 ICC/ANSI A117. FOR THE | | | PURPOSES OF THIS REVIEW I WILL BE USING THE 2009 | | | ICC/ANSI A117. | | | | | | 2) GN100: PLEASE PROVIDE A LIST OF DWELLING UNITS, THE | | | UNIT FLOOR LEVELS, AND COMMON AREAS THAT WILL BE | | | ALTERED AND IMPROVED IN ACCORDANCE WITH THE CHOSEN | | | ACCESSIBILITY STANDARD. INDICATE WHICH ADMINISTRATIVE | | | AUTHORITY HAS DETERMINED THE TYPE A DESIGN TO BE USED | | | AND THE NUMBER OF DWELLING UNITS TO BE REMODELED. | | | | | | 3) GN101: PLEASE IDENTIFY THE DESIGN STANDARD FOR THE | | | TYPICAL DETAILS- SECTION 107.2.1 WPB. IF THE TYPICAL | | | DETAILS ARE TO BE USED, AND NOT SITE SPECIFIC DETAILS, | | | PLEASE REFERENCE THE SHEET AND DETAILS ON ALL | | | APPLICABLE PLAN SHEETS. | | | | | | A) PROVIDE THE STRUCTURAL STRENGTH OF THE GRAB BARS IN | | | THE MOUNTING DETAIL - SECTION 609.8 2009 ICC/ANSI A117. | | | | | | 4) GN102 & A805- 2009 ICC/ANSI A117: | | | | | | A) SHOW THE LOCATION OF THE LAVATORY ON GN 102- SECTION | | | 1002.11.2. | | | | | | B) PROVIDE THE TURNING CIRCLE DIAMETER- 1003.3.2. | | | | | | C) THE REQUIRED CLEAR FLOOR SPACE FOR THE WATER CLOSET | | | IS 60 INCHES MINIMUM IN WIDTH MEASURED PERPENDICULAR | | | FROM THE SIDE WALL, AND 56 INCHES MINIMUM IN DEPTH FROM | | | THE REAR WALL- 1003.11.2.4.2 & 1003.11.2.4.3. THE CLEAR | | | FLOOR SPACE SHALL NOT OVERLAP THE LAVATORY- | | | 1003.11.2.4.4 UNLESS MEETING THE EXCEPTION. PLEASE | | | PROVIDE EVIDENCE OF COMPLIANCE. | | | | | | D) SHOW THE MAXIMUM DISTANCE FROM THE SHOWER SIDE WALLS | | | TO THE GRAB BARS- FIGURE 608.3.2. | | | | | | E) THE CONTROLS AND HAND SHOWER SHALL BE LOCATED ON THE | | | BACK WALL OF THE SHOWER ABOVE THE GRAB BAR, 48 INCHES | | | MAXIMUM ABOVE THE SHOWER FLOOR AND 16 INCHES MINIMUM | | | AND 27 INCHES MAXIMUM FROM THE END WALL BEHIND THE SET- | | | SECTION AND FIGURE 608.4.2. | | | | | | F) THE HORIZONTAL GRAB BARS SHALL BE INSTALLED 33 | | | INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISHED | | | BATHROOM FLOOR AND SHOWER FLOOR TO THE TOPS OF THE | | | GRIPPING SURFACES- 609.4 | | | | | | G) SHOW THE SHOWER SEAT DIMENSIONS AND EDGE CLEARANCE | | | DISTANCES IN ACCORDANCE WITH SECTION AND FIGURE | | | 610.3.1. | | | | | | H) PROVIDE DETAILS FOR THE KITCHEN SINK REMOVAL CABINET | | | INDICATING COMPLIANCE WITH SECTION 1003.12.4.1 ITEMS 1 | | | & 2 (A, B, & C). | | | | | | 5) GN103 & A806: 2009 ICC/ANSI A117: | | | | | | A) SHOW THE LOCATION OF THE LAVATORY- SECTION | | | 1002.11.2. | | | | | | B) PROVIDE THE TURNING CIRCLE DIAMETER- 1003.3.2. THE | | | TURNING CIRCLE IS SHOWN OVERLAPPING THE SHOWER FLOOR. | | | PLEASE PROVIDE A DETAIL SHOWING COMPLIANCE WITH SECTION | | | 303 FOR THE SHOWER THRESHOLD, AND THE REQUIRED KNEE AND | | | TOE CLEARANCES AT THE SHOWER SEAT- 304.3 & 306. | | | | | | C) THE REQUIRED CLEAR FLOOR SPACE FOR THE WATER CLOSET | | | IS 60 INCHES MINIMUM IN WIDTH MEASURED PERPENDICULAR | | | FROM THE SIDE WALL, AND 56 INCHES MINIMUM IN DEPTH FROM | | | THE REAR WALL- 1003.11.2.4.2 & 1003.11.2.4.3. THE CLEAR | | | FLOOR SPACE SHALL NOT OVERLAP THE LAVATORY- | | | 1003.11.2.4.4 UNLESS MEETING THE EXCEPTION. PLEASE | | | PROVIDE EVIDENCE OF COMPLIANCE. | | | | | | D) SHOW THE MAXIMUM DISTANCE FROM THE SHOWER SIDE WALLS | | | TO THE GRAB BARS- FIGURE 608.3.2. | | | | | | E) THE CONTROLS AND HAND SHOWER SHALL BE LOCATED ON THE | | | BACK WALL OF THE SHOWER ABOVE THE GRAB BAR, 48 INCHES | | | MAXIMUM ABOVE THE SHOWER FLOOR AND 16 INCHES MINIMUM | | | AND 27 INCHES MAXIMUM FROM THE END WALL BEHIND THE SET- | | | SECTION AND FIGURE 608.4.2. | | | | | | F) THE HORIZONTAL GRAB BARS SHALL BE INSTALLED 33 | | | INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISHED | | | BATHROOM FLOOR AND SHOWER FLOOR TO THE TOPS OF THE | | | GRIPPING SURFACES- 609.4 | | | | | | G) SHOW THE SHOWER SEAT DIMENSIONS AND EDGE CLEARANCE | | | DISTANCES IN ACCORDANCE WITH SECTION AND FIGURE | | | 610.3.1. | | | | | | H) PROVIDE DETAILS FOR THE KITCHEN SINK REMOVAL CABINET | | | INDICATING COMPLIANCE WITH SECTION 1003.12.4.1 ITEMS 1 | | | & 2 (A, B, & C). | | | | | | 6) A101.A: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND | | | DIMENSIONS FOR THE LOUNGE SINK- SECTION 606.2. | | | | | | 7) A101.B: PROVIDE ENLARGED MEN'S AND WOMEN'S BATHROOM | | | DRAWINGS INDICATING PLUMBING FIXTURE INSTALLATION | | | COMPLIANCE WITH THE FBC ACCESSIBILITY CODE- 2020. BASED | | | ON THE PLANS IT APPEARS THESE BATHROOMS ARE FOR BOTH | | | PRIVATE AND PUBLIC USE. PLEASE SEE SECTION 213.3 AND | | | PROVIDE DRAWINGS AND DETAILS IN COMPLIANCE WITH THE FBC | | | ACC: | | | | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSETS- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SECTION 606.2. | | | C) TURNING SPACE DIAMETERS- SECTION 304.3. | | | D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE | | | WALLS- SECTION 604.2. | | | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | F) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE | | | FROM THE FINISHED FLOOR- SECTION 606.3. | | | G) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | | THE REFLECTIVE SURFACES- SECTION 603.3 | | | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604. | | | I) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS - | | | SECTION 604.6. | | | J) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | K) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 606.2 | | | | | | 8) P101, P102, P103: PROVIDE SANITARY DRAINAGE AND VENT | | | AND WATER SUPPLY RISER DRAWINGS FOR THE NEW PLUMBING | | | FIXTURE INSTALLATIONS IN THE NEW LOUNGE AND THE | | | REMODELED ACCESSIBLE DWELLING UNITS- SECTION | | | 107.3.5.1.3 WPB. | | | | | | 9) P101 NEW ENTRY CANOPY ROOF DRAINAGE- SECTION 1101 | | | FBC P. | | | | | | A) PROVIDE A ROOF PLAN SHOWING THE LOCATIONS OF PRIMARY | | | AND SECONDARY ROOF DRAINS, THE DRAINAGE FLOW PATTERNS, | | | AND SQUARE FOOTAGE AND GPM FLOW CALCULATIONS. | | | | | | B) VERIFY THE ROOF AND DRAINAGE SYSTEM HAS BEEN | | | DESIGNED IN COMPLIANCE WITH SECTION 1101.7 FOR MAXIMUM | | | DEPTH OF PONDING WATER AND DEFLECTED STRUCTURAL | | | ELEMENTS. | | | | | | C) PROVIDE SIZING CALCULATIONS FOR THE PRIMARY VERTICAL | | | LEADERS AND HORIZONTAL BRANCHES BASED ON SECTIONS | | | 1106.1 & 1106.2. | | | | | | D) PROVIDE SIZING CALCULATIONS FOR THE SECONDARY ROOF | | | DRAINS- SECTION 1108.3. | | | | | | E) PROVIDE PRIMARY AND SECONDARY ROOF DRAIN | | | INSTALLATION DETAILS- SECTIONS 1105.1, 1106.5, & | | | 1108.1. | | | | | | F) PROVIDE CIVIL PLANS SHOWING POINTS OF CONNECTIONS TO | | | EXISTING SANITARY SEWER AND STORM DRAIN MAINS- SECTION | | | 107.2.1 WPB. | | | | | | G) PROVIDE A RISER DRAWING- SECTION 107.3.5.1.3 WPB. | | | | | | 10) P201: PROVIDE A PLUMBING FIXTURE SCHEDULE SHOWING | | | THE MAKES AND MODELS OF WATER CLOSETS, LAVATORIES, | | | SINKS, FAUCETS, SHOWER VALVES, TUB AND SHOWER VALVES, | | | ARE MEETING COMPLIANCE WITH THE 2009 ICC/ANSI A117 | | | STANDARD. | | | | | | 11) P101: WASTE STACK OFFSETS ARE PROHIBITED BETWEEN | | | THE LOWEST FIXTURE DRAIN AND HIGHEST FIXTURE DRAIN | | | CONNECTIONS- SECTION 913 FBC P. | | | | | | 12) P301: PROVIDE UL TESTED AND APPROVED FIRESTOPPING | | | ASSEMBLY DETAILS FOR PIPE PENETRATIONS ON THE PLAN- | | | SECTION 315.1 FBC P AND SECTION 714.4.1.2 FBC B. THE | | | DETAIL PROVIDED DOES NOT MEET COMPLIANCE. | | | | | | 13) P401: PROVIDE CAST IRON PIPE AND FITTING | | | SPECIFICATIONS IN COMPLIANCE WITH SECTION 303.5 P. | | | | | | CAST-IRON SOIL PIPES AND FITTINGS, AND THE COUPLINGS | | | USED TO JOIN THESE PRODUCTS TOGETHER, SHALL BE | | | THIRD-PARTY LISTED AND LABELED. THIRD-PARTY CERTIFIERS | | | OR INSPECTORS SHALL COMPLY WITH THE MINIMUM INSPECTION | | | REQUIREMENTS OF ANNEX A OR ANNEX A1 OF THE ASTM AND | | | CISPI PRODUCT STANDARDS INDICATED IN THE CODE FOR SUCH | | | PRODUCTS. | | | | | | 14) PROVIDE THE INTERIOR WALL SURROUND FINISH DETAILS | | | FOR THE WATER CLOSETS IN ACCORDANCE WITH SECTION 310.3 | | | FBC P SECTION 1210.2.2 FBC B. | | | | | | 15) P106: PROVIDE A NEW ROOF DRAIN INSTALLATION DETAIL- | | | SECTION 1105.1 FBC P. | | | | | | 16) P106: PLEASE ADD A NOTE OR REVISE THE NOTES TO | | | CLARIFY IF THE WATER HEATERS ARE BEING REPLACED IN THE | | | EXACT SAME LOCATIONS OR BEING RELOCATED. PROVIDE A | | | PIPING DIAGRAM SHOWING WATER PIPING POINTS OF | | | CONNECTIONS TO EXISTING PIPING, AND THE LOCATIONS OF | | | THE NEW EXPANSION TANK, RECIRCULATION PUMP, CHECK | | | VALVES, DRAIN PANS, PAN DRAIN LINE RUNS AND DISCHARGE | | | LOCATIONS- SECTIONS 502, 607.2 & 607.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-12 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-12 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2021-10-12 14:57:31 | ROOFING TO BE DEFERRED |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-13 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-13 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2021-09-13 10:50:55 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE THE (DESIGNER OF RECORD | | | REVIEW STAMP APPROVED) PRODUCT APPROVALS FOR ALL | | | ROOFING SYSTEMS & MATERIALS TO BE USED. | | | NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF | | | WORK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-01 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-01 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2021-11-01 11:50:22 | REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-28 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-28 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2021-10-28 08:54:30 | SIGNATURE REVIEW | | | | | | DRAWING LABELED "031 A101.B PROPOSED PARTIAL GROUND | | | FLOOR PLAN.PDF V4 " IN PROJECTDOX DOES NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | 031 A101.B PROPOSED PARTIAL GROUND FLOOR PLAN.PDF V4 | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-10-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-02 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-02 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2021-10-02 09:37:44 | THE FOLLOWING SHEETS DO NOT HAVE A DIGITAL SIGNATURE: | | | ED 101, A 805, E 205, FPD 104, A 302, E 204, E202 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-09-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-08 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-08 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2021-09-08 09:30:52 | SEE 1ST CYCLE REVIEW COMMENTS BELOW: | | | | | | THE DRAWINGS DIGITALLY UPLOADED ARE COPIES OF THE | | | DESIGNERS WET SEAL AND SIGNATURE. PLEASE UPLOAD | | | ORIGINAL DIGITALLY SIGNED DRAWINGS FROM THE DESIGNERS. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-22 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-22 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2021-07-22 08:46:49 | THE DRAWINGS DIGITALLY UPLOADED ARE COPIES OF THE | | | DESIGNERS WET SEAL AND SIGNATURE. PLEASE UPLOAD | | | ORIGINAL DIGITALLY SIGNED DRAWINGS FROM THE DESIGNERS. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2021-10-05 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-10-05 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2021-10-01 10:31:17 | 1. WILL REQUIRE A SEPARATE SUBMITTED LANDSCAPE PERMIT | | | OR LANDSCAPE APPLICATION BEFORE PASSING ZONING. | | | | | | ZONING PROVISOS: | | | | | | 1. ANY SIGNS ON THE EXTERIOR OF BUILDING WILL REQUIRE A | | | SEPARATE PERMIT. | | | 2. ANY NEW OR REPLACED MECHANICAL EQUIPMENT ON THE ROOF | | | SHALL REQUIRE VISIBILITY SCREENING, AT LEAST EQUAL IN | | | HEIGHT TO THE NEWLY PROPOSED MECHANICAL EQUIPMENT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-16 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2021-09-16 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-09-16 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2021-09-16 09:04:29 | 1. SHOULD ANY EXISTING EQUIPMENT ON THE ROOF BE | | | REPLACED DUE TO ITS CONDITION BEING UNREPAIRABLE, OR | | | ANY NEWLY INSTALLED MECHANICAL EQUIPMENT, THE | | | REPLACEMENT/NEWLY INSTALLED EQUIPMENT SHALL BE SCREENED | | | FROM VIEW. | | | | | | 2. [SEC.94-113] DUE TO THE PERMIT VALUE EXCEEDING 50% | | | OF THE ASSESSED IMPROVEMENT VALUE OF THE PROPERTY (AS | | | DETERMINED BY PALM BEACH COUNTY PROPERTY APPRAISERS | | | OFFICE). THIS TRIGGERS A REVIEW/COMPLIANCE WITH THE | | | LANDSCAPE CODE. PLEASE PROVIDE COPIES OF/RECORDS OF THE | | | APPROVED SITE PLAN AND LANDSCAPE PLANS OF THE EXISTING | | | BUILDINGS TO CONFIRM/DETERMINE IF ALL ORIGINAL | | | LANDSCAPING (PLANTS, TREES, SHRUBS, ETC.) OF THE | | | APPROVED PLANS ARE INCLUDED/EXISTING ONSITE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-08-16 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-08-16 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2021-08-16 15:41:47 | - LANDSCAPE AND STREETSCAPE REQUIRES IMPROVEMENTS, DUE | | | TO THE PERMIT VALUE EXCEEDING 50% OF THE ASSESSED | | | IMPROVEMENT VALUE OF THE PROPERTY. SITE SHALL BE | | | BROUGHT INTO COMPLIANCE WITH THE CODE; SPECIFICALLY | | | REGARDING LIGHT FIXTURES ON SIDEWALK, PLANTING OF SHADE | | | TREES ALONG FRONTAGE, PARKING STRIPING, TERMINAL | | | ISLANDS, AND OTHER LANDSCAPE/STREETSCAPE IMPROVEMENTS. | | | STAFF RECOMMENDS SEPARATE MEETING TO DISCUSS CHANGES | | | AND ACTIONS NECESSARY. | | | | | | - WITH THE REPLACEMENT OF THE ROOF, ANY NEW MECHANICAL | | | EQUIPMENT SHALL BE SCREENED. | | | | | | - THE GARBAGE ENCLOSURE FENCING WILL REQUIRE A SEPARATE | | | PERMIT. ADDITIONALLY THE GARBAGE ENCLOSURE SHALL BE | | | SCREENED WITH A HEDGE OR LANDSCAPING. | | | | | | - SIGNAGE WILL ALSO REQUIRE A SEPARATE PERMIT. | | | | | | - PLEASE PROVIDE HEIGHT/VERTICAL CLEARANCE | | | DIMENSION/MEASUREMENT FROM THE SIDEWALK ELEVATION FOR | | | THE PROPOSED COLONNADE/CANOPY. |
|
|