Plan Review Details - Permit 21070101
| Plan Review Stops For Permit 21070101 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-12-02 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-02 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2021-12-02 15:53:57 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW APPROVED WITH PROVISOS: | | | | | | 1.) PROVIDE ENGINEER'S LETTER STATING THAT THIS | | | BUILDING IS OF A CONSTRUCTION TYPE VB. | | | 2.) AT TIME OF INSPECTOR, PROVIDE TO FIELD INSPECTOR | | | THE TRUSS ENGINEERING PACKAGE (REVIEW STAMP APPROVED) | | | BY DESIGNER OF RECORD. | | | 3.) WINDLOADS/WIND DESIGN INFORMATION NEEDS TO BE | | | CHANGED FROM ASCE 7-10 TO ASCE 7-16. | | | 4.) PROVIDE AN ATTIC ACCESS OPENING FROM CEILING. THIS | | | IS TO BE INSPECTED AT TIME OF FIELD INSPECTION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-20 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-20 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2021-08-20 10:21:42 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, IN ADDITION TO THE TRUSS ENGINEERING | | | PACKAGE, PLEASE PROVIDE A PLAN THAT INCLUDES THE LAYOUT | | | AND DETAILS OF THE EXISTING STRUCTURE. THE DETAILS ON | | | THE PLANS WILL NEED TO INCLUDE THE WINDLOAD DESIGN | | | PRESSURES, BRACING, AND CONNECTION OF EACH TRUSS TO | | | STRUCTURE SPECIFICATIONS. | | | | | | THE PLANS/SUBMITTALS BY THE DESIGNER OF RECORD | | | (ENGINEER/ARCHITECT) WILL NEED TO BE SIGNED & SEALED BY | | | THE DESIGNER OF RECORD. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-12-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-08 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-08 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-12-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2021-12-06 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2021-12-06 11:40:42 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-08 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-08 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-20 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-07-13 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-12-03 |
Time |
05:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-03 |
Time |
05:43 |
Sent To |
|
|
| Notes |
| 2021-12-03 05:59:24 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOF REVIEW APPROVED WITH PROVISO: | | | | | | FBC B 107.2.1: | | | DESIGNER OF RECORD REVIEW STAMP APPROVED PRODUCT | | | APPROVALS ARE REQUIRED FOR ROOFING MATERIALS TO BE | | | USED. | | | A ROOFING SUB-PERMIT IS REQUIRED BY A ROOFING | | | CONTRACTOR. | | | FBC B 1507.1.1.1, THE ROOF UNDERLAYMENT APPLICATION | | | MUST BE DOUBLE LAYERED OR APPLIED IN ACCORDANCE WITH | | | ONE OF THE OTHER METHODS INDICATED WITHIN THIS CODE | | | SECTION. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-12-02 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-02 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
|