Plan Review Details - Permit 21070024
Plan Review Stops For Permit 21070024
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-12-08 Cont ID  
Sent By cpuell Date 2021-12-08 Time 11:07 Rev Time 0.00
Received By cpuell Date 2021-12-08 Time 11:07 Sent To  
Notes
2021-12-08 11:10:53REAR BUILDING GIVEN THE ADDRESS OF 328 EDGEWOOD DR,
 PERMITS UPDATED WITH NEW ADDRESS

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-12-01 Cont ID  
Sent By cpuell Date 2021-12-01 Time 14:47 Rev Time 0.00
Received By cpuell Date 2021-12-01 Time 14:47 Sent To  
Notes
2021-12-01 14:48:29PROPOSED ADDRESS OF 328 EDGEWOOD DR TO CHEF ARMANDO
 YAGUES, WAITING ON CONFIRMATION

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-11-16 Cont ID  
Sent By cpuell Date 2021-11-16 Time 10:47 Rev Time 0.00
Received By cpuell Date 2021-11-16 Time 10:47 Sent To  
Notes
2021-11-16 10:47:58PLEASE COORDINATE WITH [email protected] FOR THE HABITABLE
 SPACE TO BE GIVEN AN ADDRESS. ALL ACCESSORY
 RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE
 STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS
 NUMBER PER CITY'S ADDRESSING POLICY. PLEASE HAVE THE
 OWNER CONTACT [email protected] OR CALL 561-805-6659

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-27 Cont ID  
Sent By cthroop Date 2021-12-27 Time 10:25 Rev Time 0.00
Received By cthroop Date 2021-12-27 Time 07:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 13:50 Rev Time 0.00
Received By cthroop Date 2021-09-25 Time 12:08 Sent To  
Notes
2021-09-25 13:56:05PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SITE PLAN. IDENTIFY ALL STRUCTURES ON
 PAECELL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE AN ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 3. PROVIDE A PRODUCT APPROVAL FOR THE EXT. SWINGING
 DOOR.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-27 Cont ID  
Sent By cthroop Date 2021-12-27 Time 10:21 Rev Time 0.00
Received By cthroop Date 2021-12-27 Time 07:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 13:59 Rev Time 0.00
Received By cthroop Date 2021-09-25 Time 12:08 Sent To  
Notes
2021-09-25 14:27:59ELECTRICAL PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ELECTRICAL PERMIT REQUIRED.
  
 2. LABLE EACH PANEL. IDENTIFY STRUCTURE EACH PANEL
 SERVES.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
 E3601.6.1MARKING OF SERVICE EQUIPMENT AND DISCONNECTS.
  
 3. REF. SUB-PANEL B (110 AMP) FOR THE FOLLOWING
 COMMENTS:
 3A) PROVIDE 2 SMALL APPLIANCE CIRCUTS.
 E3901.3 SMALL APPLIANCE RECEPTACLES.
 3B) REMOVE ONE OF THE 20 AMP CIRCUTS SERVICING THE
 DISPOSAL. (ONLY ONE IS REQUIRED)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 4. R404.1LIGHTING EQUIPMENT (MANDATORY).
 NOT LESS THAN 75 PERCENT OF THE LAMPS IN PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY
 LAMPS OR NOT LESS THAN 75 PERCENT OF THE PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY
 HIGH-EFFICACY LAMPS.
 EXCEPTION: LOW-VOLTAGE LIGHTING.
 A NOTE ON THE PLAN WILL SUFFICE. FBC EC R404.1
  
 5. E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH
 DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL.
  
 6. FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO
 FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS.
 R314.1 GENERAL.
 SMOKE ALARMS SHALL COMPLY WITH NFPA 72 AND SECTION
 R314.
  
 7. AHU IN ATTIC: M1305.1.3.1 ELECTRICAL REQUIREMENTS.
 A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE
 REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET
 SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN
 ACCORDANCE WITH CHAPTER 39. EXPOSED LAMPS SHALL BE
 PROTECTED FROM DAMAGE BY LOCATION OR LAMP GUARDS.
 E3901.12 HVAC OUTLET. EQUIPMENT SERVICE OUTLET:
 A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING
 AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE
 LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM)
 OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION
 EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED
 TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING
 MEANS. (210.63)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-09-22 Cont ID  
Sent By lcrespo Date 2021-09-22 Time 08:11 Rev Time 0.00
Received By lcrespo Date 2021-09-22 Time 08:11 Sent To  
Notes
2021-09-22 08:12:05GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT
 BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND
 PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-01-03 Cont ID  
Sent By fmittner Date 2022-01-03 Time 11:11 Rev Time 0.00
Received By fmittner Date 2022-01-03 Time 11:11 Sent To  
Notes
2022-01-03 11:11:46HPB APPROVED EXTERIOR MODIFICATIONS

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2021-10-25 Cont ID  
Sent By amhamilt Date 2021-10-25 Time 11:46 Rev Time 0.00
Received By amhamilt Date 2021-10-25 Time 11:46 Sent To  
Notes
2021-10-25 11:47:30THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 AS DISCUSSED WITH THE OWNER, WORK REQUIRES A COA
 APPLICATION TO BE FILLED OUT.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 561.822.1428
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-07-14 Cont ID  
Sent By aoliver Date 2022-07-14 Time 08:03 Rev Time 0.00
Received By aoliver Date 2022-06-18 Time 06:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-05-02 Cont ID  
Sent By aoliver Date 2022-05-02 Time 08:06 Rev Time 0.00
Received By aoliver Date 2022-04-07 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-04 Cont ID  
Sent By lmarchan Date 2022-01-04 Time 10:32 Rev Time 0.00
Received By lmarchan Date 2021-12-21 Time 08:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-28 Cont ID  
Sent By lmarchan Date 2021-10-28 Time 12:18 Rev Time 0.00
Received By lmarchan Date 2021-09-20 Time 11:37 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-02-18 Cont ID  
Sent By lmarchan Date 2022-02-18 Time 10:35 Rev Time 0.00
Received By lmarchan Date 2022-02-10 Time 12:32 Sent To  
Notes
2022-02-17 13:45:03RECEIPT MU-2022-006997-0000 - $4,304.62 PAID
2022-02-10 12:32:442/10/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 13:56 Rev Time 0.00
Received By cthroop Date 2021-09-25 Time 13:56 Sent To  
Notes
2021-09-25 13:57:00PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-06-21 Cont ID  
Sent By medwards Date 2022-06-21 Time 11:26 Rev Time 0.00
Received By medwards Date 2022-06-21 Time 11:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2022-04-11 Cont ID  
Sent By medwards Date 2022-04-11 Time 09:33 Rev Time 0.00
Received By medwards Date 2022-04-11 Time 09:33 Sent To  
Notes
2022-04-11 09:34:25I DO NOT SEE THAT THE MECHANICAL REVIEW COMMENTS HAVE
 BEEN ADDRESSED. PLEASE SEE PREVIOUS COMMENTS BELOW:
  
 PLEASE RESPOND TO THE 1ST CYCLE MECHANICAL REVIEW
 COMMENTS BELOW:
  
 1ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21070024
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS
 CHANGE OF USE OF THE GARAGE TO A LIVING SPACE. FBC EC
 101.5.1.1.2
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC R403.7.1
  
 3) PLEASE PROVIDE A MECHANICAL DRAWING FOR THE
 MECHANICAL SYSTEM INSTALLATION INCLUDING THE CONDENSING
 UNIT TIE DOWN. FBC 107.2.1
  
 4) PLEASE PROVIDE DETAILS OF THE COOKING EQUIPMENT
 BEING INSTALLED UNDER THE HOOD. FBC 107.2.1
  
 M1302.1 LISTED AND LABELED. APPLIANCES REGULATED BY
 THIS CODE SHALL BE LISTED AND LABELED FOR THE
 APPLICATION IN WHICH THEY ARE INSTALLED AND USED,
 UNLESS OTHERWISE APPROVED IN ACCORDANCE WITH SECTION
 R104.11.
  
 5) THIS IS A RESIDENTIAL BUILDING, PLEASE PROVIDE
 DETAILS FOR THE TYPE 1 HOOD AND SHOW IT CAN BE
 INSTALLED IN A RESIDENTIAL OCCUPANCY. IF THIS CAN BE
 SHOWN PLEASE SHOW DETAILS OF THE HOOD BEING MOUNTED
 WITH THE CLEARANCES TO COMBUSTIBLES. ALONG WITH THE
 GREASE DUCT. FBC 107.2.1
  
 6) A MECHANICAL PERMIT WILL BE REQUIRED FOR THE
 MECHANICAL SYSTEM FOR THIS BUILDING.
  
 7) A SEPARATE MECHANICAL PERMIT WILL BE REQUIRED FOR
 THE HOOD SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-12-22 Cont ID  
Sent By medwards Date 2021-12-22 Time 07:48 Rev Time 0.00
Received By medwards Date 2021-12-22 Time 07:48 Sent To  
Notes
2021-12-22 07:49:03PLEASE RESPOND TO THE 1ST CYCLE MECHANICAL REVIEW
 COMMENTS BELOW:
  
 1ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21070024
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS
 CHANGE OF USE OF THE GARAGE TO A LIVING SPACE. FBC EC
 101.5.1.1.2
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC R403.7.1
  
 3) PLEASE PROVIDE A MECHANICAL DRAWING FOR THE
 MECHANICAL SYSTEM INSTALLATION INCLUDING THE CONDENSING
 UNIT TIE DOWN. FBC 107.2.1
  
 4) PLEASE PROVIDE DETAILS OF THE COOKING EQUIPMENT
 BEING INSTALLED UNDER THE HOOD. FBC 107.2.1
  
 M1302.1 LISTED AND LABELED. APPLIANCES REGULATED BY
 THIS CODE SHALL BE LISTED AND LABELED FOR THE
 APPLICATION IN WHICH THEY ARE INSTALLED AND USED,
 UNLESS OTHERWISE APPROVED IN ACCORDANCE WITH SECTION
 R104.11.
  
 5) THIS IS A RESIDENTIAL BUILDING, PLEASE PROVIDE
 DETAILS FOR THE TYPE 1 HOOD AND SHOW IT CAN BE
 INSTALLED IN A RESIDENTIAL OCCUPANCY. IF THIS CAN BE
 SHOWN PLEASE SHOW DETAILS OF THE HOOD BEING MOUNTED
 WITH THE CLEARANCES TO COMBUSTIBLES. ALONG WITH THE
 GREASE DUCT. FBC 107.2.1
  
 6) A MECHANICAL PERMIT WILL BE REQUIRED FOR THE
 MECHANICAL SYSTEM FOR THIS BUILDING.
  
 7) A SEPARATE MECHANICAL PERMIT WILL BE REQUIRED FOR
 THE HOOD SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-09-22 Cont ID  
Sent By medwards Date 2021-09-22 Time 08:45 Rev Time 0.00
Received By medwards Date 2021-09-22 Time 08:45 Sent To  
Notes
2021-09-22 08:46:081ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21070024
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS
 CHANGE OF USE OF THE GARAGE TO A LIVING SPACE. FBC EC
 101.5.1.1.2
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC R403.7.1
  
 3) PLEASE PROVIDE A MECHANICAL DRAWING FOR THE
 MECHANICAL SYSTEM INSTALLATION INCLUDING THE CONDENSING
 UNIT TIE DOWN. FBC 107.2.1
  
 4) PLEASE PROVIDE DETAILS OF THE COOKING EQUIPMENT
 BEING INSTALLED UNDER THE HOOD. FBC 107.2.1
  
 M1302.1 LISTED AND LABELED. APPLIANCES REGULATED BY
 THIS CODE SHALL BE LISTED AND LABELED FOR THE
 APPLICATION IN WHICH THEY ARE INSTALLED AND USED,
 UNLESS OTHERWISE APPROVED IN ACCORDANCE WITH SECTION
 R104.11.
  
 5) THIS IS A RESIDENTIAL BUILDING, PLEASE PROVIDE
 DETAILS FOR THE TYPE 1 HOOD AND SHOW IT CAN BE
 INSTALLED IN A RESIDENTIAL OCCUPANCY. IF THIS CAN BE
 SHOWN PLEASE SHOW DETAILS OF THE HOOD BEING MOUNTED
 WITH THE CLEARANCES TO COMBUSTIBLES. ALONG WITH THE
 GREASE DUCT. FBC 107.2.1
  
 6) A MECHANICAL PERMIT WILL BE REQUIRED FOR THE
 MECHANICAL SYSTEM FOR THIS BUILDING.
  
 7) A SEPARATE MECHANICAL PERMIT WILL BE REQUIRED FOR
 THE HOOD SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-23 Cont ID  
Sent By ccole Date 2021-12-23 Time 07:31 Rev Time 0.00
Received By ccole Date 2021-12-23 Time 07:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-09-22 Cont ID  
Sent By lcrespo Date 2021-09-22 Time 08:12 Rev Time 0.00
Received By lcrespo Date 2021-09-22 Time 07:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-06-21 Cont ID  
Sent By medwards Date 2022-06-21 Time 11:27 Rev Time 0.00
Received By medwards Date 2022-06-21 Time 11:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-12-27 Cont ID  
Sent By cthroop Date 2021-12-27 Time 10:21 Rev Time 0.00
Received By cthroop Date 2021-12-27 Time 07:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 13:59 Rev Time 0.00
Received By cthroop Date 2021-09-25 Time 12:08 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 2022-08-26 Cont ID  
Sent By amhamilt Date 2022-08-26 Time 09:31 Rev Time 0.00
Received By amhamilt Date 2022-08-26 Time 09:31 Sent To  
Notes
2022-08-26 09:32:24CLASS B SPECIAL USE PERMIT APPROVED AT 8/23/22 HPB
 MEETING (HPB 22-74)
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 4 Status F Date 2022-07-13 Cont ID  
Sent By amhamilt Date 2022-07-13 Time 11:01 Rev Time 0.00
Received By amhamilt Date 2022-07-13 Time 11:00 Sent To  
Notes
2022-07-13 11:02:39THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 WAITING ON CLASS B APPROVAL, SCHEDULED FOR 7/26 HPB
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 3 Status F Date 2022-04-29 Cont ID  
Sent By amhamilt Date 2022-04-29 Time 11:26 Rev Time 0.00
Received By amhamilt Date 2022-04-29 Time 11:26 Sent To  
Notes
2022-04-29 11:27:21THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 AS PER PREVIOUS COMMENTS, ADDITIONAL COOKING FACILITIES
 ARE NOT PERMITTED IN REAR UNIT. REVISE PLANS TO REMOVE
 REFERENCE TO COOKING FACILITY OR APPLY FOR CLASS B
 SPECIAL USE PERMIT.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 2 Status F Date 2022-01-03 Cont ID  
Sent By fmittner Date 2022-01-03 Time 11:11 Rev Time 0.00
Received By fmittner Date 2022-01-03 Time 11:11 Sent To  
Notes
2022-01-03 11:12:35COOKING FACITILITY NOT PERMITTED IN REAR UNIT....NO
 STOVE/OVEN/RANGE ETC.

Review Stop Z ZONING
Rev No 1 Status F Date 2021-10-27 Cont ID  
Sent By av Date 2021-10-27 Time 16:28 Rev Time 0.00
Received By amhamilt Date 2021-10-27 Time 16:28 Sent To  
Notes
2021-10-27 16:28:36THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 SEE HISTORIC NOTES, ADDITIONAL ZONING REVIEW WILL BE
 DONE AFTER SUBMITAL OF COA
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 561.822.1428
 [email protected]
  