| Plan Review Stops For Permit 21061741 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2021-09-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-09-22 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-24 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-23 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2021-09-24 10:17:38 | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW APPROVED WITH PROVISOS: | | | ALL SUB-PERMITS ARE REQUIRED PRIOR TO WORK UNDER THOSE | | | PERMITS INCLUDING ROOFING. | | | ALL SEPERATE PERMITS ARE REQUIRED PRIOR TO WORK UNDER | | | THOSE PERMITS INCLUDING: PARKING/STRIPING, EXTERIOR | | | SIGNAGE, EXTERIOR CANOPIES, DUMPSTER ENCLOSURES & | | | GENERATOR. | | | ALL SHOP DRAWINGS AND PRODUCT APPROVALS ARE REQUIRED TO | | | BE SUBMITTED AS DEFERRED SUBMITTALS AND WILL HAVE TO BE | | | REVIEW STAMP APPROVED BY DESIGNER OF RECORD. | | | SPECIAL INSPECTOR WILL BE REQUIRED. | | | | | | FOR ALL WELDING CONNECTIONS PLEASE SEE NOTE BELOW: | | | AWS D1.1 CLAUSE 5.2 & 6.7: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | | BE USED. | | | AWS D1.1 CLAUSE 6.16: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-17 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-12 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2021-08-17 16:09:08 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1) PROVIDE NOTES THAT INDICATE, DETAILS FOR THE | | | PEDESTRIAN BRIDGE CAN BE FOUND ON THE PEDESTRIAN BRIDGE | | | PERMIT # 21070960. | | | IS THERE AN APPROVED PLAN/SUBMITTAL, FOR THE BRIDGE, BY | | | A STATE OR FEDERAL AGENCY RELATED TO THE TRAIN SYSTEM? | | | | | | 2) THE CORRIDOR ON THE LIFE SAFETY SHEET (B101) DOES | | | NOT HAVE INDICATIONS OF WIDTHS/LENGTHS. THE CORRIDOR IS | | | MISSING IDENTIFICATION ON THE PLAN SHEETS AS AN EXIT | | | PASSAGEWAY. THIS WILL BE REQUIRED IF IT IS AN EXIT | | | PASSAGEWAY, PENDING CLASSIFICATION OF SPACES AND | | | REVISION OF THIS SHEET. | | | | | | 3) THE LIFE SAFETY SHEET (B101) NEEDS TO BE REVISED. | | | THE INFORMATION APPEARS TO HAVE CHANGED FROM MERCANTILE | | | & WAREHOUSES TO RESTAURANTS AND OR ASSEMBLY. IN ORDER | | | TO MOVE FORWARD, THIS NEEDS TO BE CLARIFIED AS TO WHAT | | | IS THE INTENDED USE OF EACH SPACE. | | | | | | 4) PROVIDE ALL SHOP DRAWINGS/PRODUCT APPROVALS | | | INCLUDING: | | | THE STEEL FRAMING AT THE PRESS ROOM, THE ROOFING | | | SYSTEM, WINDOWS/DOORS, STOREFRONTS, ... | | | | | | 5) A SUB-PERMIT IS REQUIRED FOR ROOFING. | | | | | | 6) SEPARATE PERMITS ARE REQUIRED FOR: PARKING/STRIPING | | | AT PARKING LOT, EXTERIOR SIGNAGE, EXTERIOR CANOPIES, | | | DUMPSTER ENCLOSURES & GENERATOR. | | | | | | 7) A DETAIL FOR THE REINFORCEMENT OF THE LOADING DOCK | | | AREA ABOVE THE INTERCEPTORS IS REQUIRED AS THIS APPEARS | | | TO BE AN AREA FOR VEHICLE TRAFFIC. | | | | | | 8) A THOROUGH REVIEW COULD NOT BE COMPLETED AT THIS | | | TIME AS MORE INFORMATION IS REQUIRED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-12 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-12 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-08-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-11 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-10 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-20 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-20 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2021-07-20 15:21:28 | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO ELECTRICAL PLANS INCLUDED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2021-10-06 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-10-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-10-06 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-07-19 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-07-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-07-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-19 12:31:10 | UNDER FORMAL ENGINEERING REVIEW (E20100035). | | | | | | THANKS, | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL | | | 33401 | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-08 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-27 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-27 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2021-09-27 09:42:12 | 09/27/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-16 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-16 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2021-08-16 18:14:53 | 08/13/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-12 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-21 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-20 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-01 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-01 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-01 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-12 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-11 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2021-08-12 16:27:35 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21061741 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THIS IS A CHANGE OF USE FROM F-2 TO MERCANTILE. | | | PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS | | | PROJECT. FBC EC C402.1 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THIS PROJECT. FBC EC C403.2.1 | | | | | | 3) SHEET M-001: THERE ARE 7 OUTDOOR UNITS BUT ONLY 5 | | | INDOOR UNITS LISTED. WHY ARE AHU-JS-05 AND AHU-JS-06 | | | MISSING FROM THE SHEET? | | | | | | 4) PLEASE SHOW THE CONDENSATION PIPING FOR THE AHU?S | | | AND THE RTU-21. PLEASE SHOW THE TERMINATION LOCATION | | | FOR EACH. FBC M 307 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-13 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-13 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2021-07-13 17:03:45 | I DO NOT SEE ANY DRAWINGS LABELED MECHANICAL NOR DO I | | | SEE SHEETS NUMBERED 109, 110, 111, 112, 113, 114, 115. | | | PLEASE EITHER EXPLAIN WHERE THESE DRAWINGS ARE LOCATED | | | OR PROVIDE THESE DRAWINGS. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-12 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-12 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2021-10-12 16:07:45 | 10/12/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-16 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-11 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2021-08-16 18:13:21 | 08/16/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET G-103; | | | A. UNDER THE PLUMBING SYSTEM, PLEASE PROVIDE THE | | | OCCUPANCY LOAD AND REQUIRED NUMBER OF FIXTURES FOR THE | | | STRUCTURE PER THE WPB AMENDMENTS TO THE FBC SEC. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | B. IF A MOP SINK IS REQUIRES THE SURROUNDING THE WALL | | | SHALL BE NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE | | | 2017 FBC BUILDING SEC. 1210.2.2 AND 2017 FBC SEC. P | | | 310.3. PLEASE MAKE A NOTE ON THIS SHEET. | | | | | | 2. PLEASE NOTE THAT THE CITY OF WEST PALM BEACH | | | REQUIRES A SEPARATE PERMIT FOR A GREASE INTERCEPTOR | | | ALONG WITH AN ENGINEERING REVIEW. UNDER GREASE | | | INTERCEPTOR, IT SAYS NOT NEEDED, BUT ON CIVIL AND | | | ARCHITUAL, IT SHOWS TWO INTERCEPTORS. YOU MAY SUBMIT | | | THE CALCULATION AT THIS TIME OR HAVE THE VERBIAGE OF | | | HOW IT WILL BE DONE. WOULD YOU PLEASE CLARIFY PER THE | | | WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 3. ON SHEET G-104; | | | | | | A. ON THE LABORATORY AND MIRRORS. WOULD YOU PLEASE SHOW | | | THE REFLECTIVE PART OF THE MIRROR TO BE THE OF 40 | | | INCHES TO THE REFLECTIVE SIDE PER THE 2017 FBC ACC SEC. | | | 603.3. | | | | | | B. WOULD YOU PLEASE SHOW THE BOTTOM ON THE LAV AT A | | | MINIMUM OF 27 INCHES KNEE CLEARANCE PER THE 2017 FBC | | | SEC. 306.3. | | | | | | 4. THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE ON THE WATER CLOSET PER THE 2017 FBC | | | ACC SEC. 609.4. | | | | | | 5. ON SHEET A-400; | | | | | | A. WOULD YOU PLEASE GIVE DIMENSIONS FOR FIXTURE | | | CLEARANCES FOR LAV, WATER CLOSET PER FLORIDA BUILDING | | | CODE AND FLORIDA ACCESSIBILITY CODE. | | | | | | B. WOULD YOU PLEASE SHOW THE 30 INCHES BY 48 INCHES | | | INSIDE THE RUNNING RADIUS PER THE 2017 FBC ACC SEC. 305 | | | CLEAR FLOOR OR GROUND SPACE. | | | | | | C. WOULD YOU PLEASE PROVIDE A NOTE FOR DETAIL OF THE | | | ACCESSIBLE ELEVATIONS DIMENSION ON G-104 PER THE WPB | | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 6. ON SHEET P-107; | | | | | | A. THIS MAY CHANGE DUE TO SIZING CALCULATION IN FUTURE | | | SPACES. A. A SEPARATE PERMIT APPLICATION AND REVIEW ARE | | | REQUIRED FROM ENGINEERING FOR THE GREASE INTERCEPTOR. | | | AT THAT TIME, PLEASE PROVIDE GREASE INTERCEPTOR | | | SPECIFICATIONS. | | | | | | B. TWO SAMPLING PORTS CANNOT BE SHARED PER THE CITY OF | | | WEST PALM BEACH PUBLIC WORKS DEPARTMENT. | | | | | | C. ON THE ISOMETRIC, IT SHOWS A WATER CLOSET ON A TRUNK | | | LINE WITHOUT BEING VENTED, AND THE END OF THE TRUCK | | | LINE HAS A FUTURE LABELED. THE WATER CLOSET NEEDS TO BE | | | VENTED FROM THE LAVS PER THE 2017 FBC SEC. 901.2. | | | | | | D. ON THE TWO WATER CLOSETS ON THE SECOND FLOOR, ONE | | | NEEDS TO HAVE A VENT PER THE 2017 FC 901.2.1 VENTING | | | REQUIRED. | | | | | | 7. WOULD YOU PLEASE PROVIDE LISTED FIRE-STOPPING | | | DETAILS FOR THE PIPPING THROUGH RATED WALLS AND THE | | | FLOORS? WOULD YOU PLEASE SUBMIT THE COMPLETE ASSEMBLY | | | DETAILS FOR THE SYSTEMS PER THE WPB AMENDMENTS TO FBC | | | SEC. 107.2.1? | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-07-20 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2021-07-20 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-16 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2021-07-20 10:49:01 | 07/20/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. THE PAGES FOR PLUMBING:- 057, 058, 059 ARE NOT | | | PRESENT AS STATED ON THE REVISION 06 CHANGE DESCRIPTION | | | TO THE SHOPS AT THE PRESS PROJECT WITH PERMIT NUMBERS | | | 19051045 (DEMO SCOPE) & 20030124 (PHASE 2, LANDLORD | | | IMPROVEMENT SCOPE) THAT ARE DOCUMENTED IN REVISON 06. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-24 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-23 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2021-09-24 08:25:59 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW: | | | | | | ROOFING SUB-PERMIT WILL BE REQUIRED PRIOR TO ANY | | | ROOFING WORK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-17 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-17 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2021-08-17 16:29:43 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW DENIED: | | | | | | PROVIDE ALL PRODUCT APPROVALS FOR ROOFING MATERIALS TO | | | BE USED AND A SUB-PERMIT FOR ROOF WORK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-01 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-01 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-12 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-12 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-11-19 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-11-19 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2021-11-19 13:17:53 | 1. SEPARATE PERMITS REQUIRED FOR SITE WORK (PARKING | | | LOT), STRIPING, HARDSCAPE, LIGHTING, LANDSCAPING, | | | IRRIGATION, ETC. | | | | | | 2. THE PERMIT PLANS SHALL BE REVISED (AS NEEDED) TO | | | REFLECT THE APPROVED PLANS ASSOCIATED WITH PB CASE NO. | | | 1086E & G. | | | | | | 3. THE PROJECT IS SUBJECT TO ALL DEVELOPMENT ORDER | | | CONDITIONS, AS OUTLINED IN RESOLUTION NO. 81-20, AS | | | APPROVED BY THE CITY COMMISSION, AS MAY BE AMENDED, AS | | | WELL AS THOSE CONDITIONS ASSOCIATED WITH PB CASE NOS. | | | 1086E & G, AS OUTLINED IN AN APPROVAL LETTER DATED | | | NOVEMBER 2, 2021. | | | _______________________________________________________ | | | _____________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-09-20 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-09-20 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2021-09-20 10:08:27 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 09.20.2021 | | | PERMIT NO.: 21061741 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE REVISED SITE PLANS, ETC. ARE CURRENTLY BEING | | | REVIEWED THROUGH THE MINOR DSI AMENDMENT PROCESS, AND | | | NEARING COMPLETION. ONCE THE MINOR AMENDMENT HAS BEEN | | | FINALIZED, ALL BUILDING PERMIT PLANS WILL NEED TO MATCH | | | THE APPROVED PLANS. PLEASE ENSURE THAT ALL PLANS | | | SUBMITTED ARE THE LATEST REVISIONS. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|