Plan Review Details - Permit 21061690
Plan Review Stops For Permit 21061690
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-09-20 Cont ID  
Sent By cthroop Date 2021-09-20 Time 15:51 Rev Time 0.00
Received By cthroop Date 2021-09-20 Time 15:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-30 Cont ID  
Sent By cthroop Date 2021-07-30 Time 09:52 Rev Time 0.00
Received By cthroop Date 2021-07-30 Time 07:13 Sent To  
Notes
2021-07-30 09:58:04PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 1. PERMIT APPLICATION STATES THIS IS A SUB-PERMIT UNDER
 BLD COMM PERMIT 20080364. POOLS SHALL BE BY SEPERATE
 PERMIT. SUBMIT A CORRECTED PERMIT APP.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE SPECIFICATIONS FOR CHAIR LIFT APPROVED UNDER
 THE 2020 FBC.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. IDENTIFY POOL BARRIER ON SITE PLAN.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 4. PROVIDE SPECIFICATIONS FOR POOL MAIN DRAIN.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-22 Cont ID  
Sent By jleahy Date 2021-07-22 Time 19:22 Rev Time 0.00
Received By jleahy Date 2021-07-22 Time 19:20 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2021-07-28 Cont ID  
Sent By mgonzale Date 2021-07-28 Time 16:13 Rev Time 0.00
Received By mgonzale Date 2021-07-28 Time 16:13 Sent To  
Notes
2021-07-28 16:13:48PROVISO
 DECHLORINATED SWIMMING POOL DISCHARGES ARE AUTHORIZED
 IN FLORIDA IN ACCORDANCE WITH 62-624.200(2)(Q), F.A.C.;
 PROVIDED THAT THEY DO NOT CAUSE A VIOLATION OF WATER
 QUALITY STANDARDS."
 SUBSECTION 62-302.530(19), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.) LIMITS THE DISCHARGE OF CHLORINE TO SURFACE
 WATER BODIES TO < 0.01 MILLIGRAM PER LITER (MG/L).
 IN ADDITION, TURBIDITY ASSOCIATED WITH BACKWASHING AND
 CLEANING CAN ALSO VIOLATE SURFACE WATER QUALITY
 STANDARDS THEREFORE POOL DISCHARGES MUST BE CONTROLLED
 AND PROGRAMMED.
 FOR REFERENCE PLEASE KNOW THAT THE FLORIDA DEPARTMENT
 OF HEALTH REGULATES PUBLIC SWIMMING POOLS AND BATHING
 PLACES. SUBSECTION 64E-9.007 (15) ?POOL WASTE WATER
 DISPOSAL? STATES IN PART: ?POOL WASTE WATER SHALL BE
 DISCHARGED THROUGH AN AIR GAP; DISPOSAL SHALL BE TO
 SANITARY SEWERS, STORM SEWERS, DRAINFIELDS, OR BY OTHER
 MEANS, IN ACCORDANCE WITH LOCAL MUNICIPAL AND BUILDING
 OFFICIAL REQUIREMENTS INCLUDING OBTAINING ALL NECESSARY
 PERMITS.?
  
 GUIDANCE:
 TO HELP PROTECT FLORIDA?S ENVIRONMENT, THE FOLLOWING
 BEST MANAGEMENT PRACTICES SHOULD BE FOLLOWED WHEN
 DRAINING SWIMMING POOLS OR DISCHARGING FILTER BACKWASH
 INTO THE ENVIRONMENT.
 ONLY DRAIN YOUR POOL WHEN NECESSARY. AVOID
 DRAINING/BACKWASHING YOUR POOL DURING PERIODS OF
 DROUGHT AND DURING SIGNIFICANT RAINFALL EVENTS. DO NOT
 DRAIN YOUR POOL WHEN WATERING RESTRICTIONS ARE IN
 PLACE.
 BEFORE DRAINING YOUR POOL, ALLOW THE WATER TO STAND FOR
 AT LEAST 48 HOURS AFTER THE LAST ADDITION OF CHLORINE
 OR UNTIL THE FREE CHLORINE RESIDUAL IS < 0.01 MG/L. (IF
 YOU NEED TO DRAIN YOUR POOL QUICKLY, YOU CAN PURCHASE
 CHLORINE-NEUTRALIZING CHEMICALS SUCH AS SODIUM
 THIOSULFATE AT YOUR LOCAL POOL SUPPLY COMPANY.)
 TEST THE FREE CHLORINE RESIDUAL BEFORE DISCHARGING. A
 FREE CHLORINE RESIDUAL SHOULD NOT BE DETECTED. THE
 CHLORINE RESIDUAL CAN BE TESTED USING A STANDARD POOL
 TEST KIT. (REFER TO 64E-9.004 (11), F.A.C. FOR
 ADDITIONAL INFORMATION.)
 THE WATER SHOULD BE CLEAR AND FREE OF SOLIDS.
 THE PH MUST BE BETWEEN 6.5 AND 8.5 BEFORE IT IS
 DISCHARGED.
 ALGAECIDES CONTAINING COPPER OR SILVER CAN INTERRUPT
 NORMAL ALGAL AND PLANT GROWTH IN SURFACE WATER BODIES
 AND SHOULD BE USED WITH CAUTION. FOLLOW THE
 MANUFACTURER?S INSTRUCTIONS BEFORE DISCHARGING WATER
 THAT HAS HAD AN ALGAECIDE ADDED RECENTLY.
 CONTROL THE RATE OF DISCHARGE ACROSS YOUR PROPERTY TO
 AVOID EROSION AND NUISANCE CONDITIONS FOR NEIGHBORING
 PROPERTIES. NUISANCE CONDITIONS SUCH AS THE CREATION OF
 ODORS, MOSQUITO BREEDING CONDITIONS, OR FLOODING CAN
 OCCUR WHEN WATER IS PONDED FOR A PROLONGED PERIOD.
 DIRECT THE DISCHARGE OVER A VEGETATED SURFACE SO THAT
 SOME LEVEL OF FILTRATION CAN OCCUR.
 DO NOT DISCHARGE ON AREAS RECENTLY TREATED WITH
 HERBICIDES OR PESTICIDES.
  
 GUIDANCE IF DISPOSING TO CITY SANITARY SEWER SYSTEM:
 POOL AND SPA WASTEWATER SHOULD NOT BE DISCHARGED INTO
 THE SANITARY SEWER SYSTEM WITHOUT THE PERMISSION OF THE
 WASTEWATER TREATMENT FACILITY.
 AVOID DISCHARGING TO THE SANITARY SEWER SYSTEM DURING
 OR IMMEDIATELY AFTER A SIGNIFICANT RAINFALL EVENT."
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 MOBILE: (561) 319-2695
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-20 Cont ID  
Sent By cthroop Date 2021-09-20 Time 15:51 Rev Time 0.00
Received By cthroop Date 2021-08-24 Time 10:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-04 Cont ID  
Sent By rmcphers Date 2021-08-04 Time 08:32 Rev Time 0.00
Received By rmcphers Date 2021-07-08 Time 11:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-03 Cont ID  
Sent By lcrespo Date 2021-09-03 Time 10:30 Rev Time 0.00
Received By lcrespo Date 2021-09-03 Time 10:30 Sent To  
Notes
2021-09-03 10:30:5109/03/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-27 Cont ID  
Sent By tklarge Date 2021-07-27 Time 05:14 Rev Time 0.00
Received By tklarge Date 2021-07-23 Time 14:13 Sent To  
Notes
2021-07-26 13:46:421) PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE POOL
 SHOWER FOR COMPLIANCE WITH ANSI A117.1-1986.
 2) THE OVERFLOW FROM THE COLLECTOR TANK CANNOT
 DISCHARGE TO THE SANITARY SYSTEM PER WPB CODE OF
 ORDINANCES CHAPTER 90, ART. III, SEC.90-126 (B) (5)
 UNLESS SPECIFICALLY AUTHORIZED BY THE CITY IN WRITING.
 PLEASE CONTACT MANNY GONZALEZ IN THE CITY'S ENGINEERING
 DEPARTMENT AT 561-494-1085 OR [email protected] FOR
 FURTHER DIRECTION.
 3) THE VOLUME OF WATER IN THE SUN SHELF SHALL BE
 FILTERED AND CHEMICALLY TREATED ONCE EVERY 60 MINUTES
 (1 HOUR) OR LESS PER FBC-BUILDING SEC.454.1.2.8.4.
 VERIFY COMPLIANCE ON THE PLANS.
 4) SHT. 4- PLUMBING NOTE #6 - SUCTION PIPING SHALL NOT
 EXCEED 6 FEET PER SECOND PER FBC-BUILDING
 SEC.454.1.6.5.8.
 5) SHT. 4 - PLUMBING NOTE #8 - PLASTIC PIPE SUBJECT TO
 A PERIOD OF PROLONGED SUNLIGHT EXPOSURE SHALL BE COATED
 TO PROTECT IT FROM ULTRAVIOLET LIGHT DEGRADATION PER
 FBC-BUILDING SEC.454.1.6.4.
 6) THE FLOW RATE THROUGH THE INLETS SHALL NOT EXCEED 20
 GPM PER FBC-BUILDING SEC.454.1.6.5.9.6. VERIFY ON THE
 PLANS THAT THIS FLOW RATE HAS NOT BEEN EXCEEDED.
 7) PAGE 6 - COLLECTOR TANK SEC. "A" - THERE IS AN ARROW
 AND LINE THAT REFERS TO A FLOW VALVE BUT NO VALVE IS
 SHOWN. CLARIFY.
 8) SUBMIT A COPY OF THE STATE OF FLORIDA DEPARTMENT OF
 HEALTH APPLICATION FOR THE OPERATING PERMIT WITH THE
 DEPARTMENT OF HEALTH'S STAMP OF RECEIPT ON IT PER FL.
 STATUTE 514.03 (1).
 9) SHT. 4 - THERE ARE NOTES THAT ARE OVERLAYED ONTO
 EACH OTHER BY THE POOL LADDER THAT MAKE THE NOTES
 ILLEGIBLE.PLEASE CLEAN UP THESE NOTES.
 10) SUPPLY TOTAL DYNAMIC HEAD CALCULATIONS TO SHOW THE
 CALCULATED FLOW RATE TO MEET THE TURNOVER RATE REQUIRED
 AND THE VELOCITY TO PROPERLY SIZE THE PIPING. APSP
 7-2013 SEC.4.4.9.2.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2021-08-07 Cont ID  
Sent By shill Date 2021-08-07 Time 13:42 Rev Time 0.00
Received By shill Date 2021-08-07 Time 13:42 Sent To  
Notes
2021-08-07 13:42:45INSPECTIONS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-09-03 Cont ID  
Sent By lcrespo Date 2021-09-03 Time 10:31 Rev Time 0.00
Received By lcrespo Date 2021-09-03 Time 10:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-07-30 Cont ID  
Sent By cthroop Date 2021-07-30 Time 09:52 Rev Time 0.00
Received By cthroop Date 2021-07-30 Time 07:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-09-02 Cont ID  
Sent By ckimmerl Date 2021-09-02 Time 10:01 Rev Time 0.00
Received By ckimmerl Date 2021-09-02 Time 10:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-08-03 Cont ID  
Sent By aaponte Date 2021-08-03 Time 16:23 Rev Time 0.00
Received By ckimmerl Date 2021-08-03 Time 16:23 Sent To  
Notes
***NONE***