Plan Review Details - Permit 21061567
Plan Review Stops For Permit 21061567
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-07-16 Cont ID  
Sent By jgomez Date 2021-07-16 Time 16:35 Rev Time 0.00
Received By jgomez Date 2021-07-16 Time 16:35 Sent To  
Notes
2021-07-16 16:36:07ASBESTOS ACKNOWLEDGMENT LETTER FROM MAC ENTERPRISES OF
 N.P.B,, INC.
 NOTE: THIS IS A SINGLE FAMILY RESIDENCE. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-19 Cont ID  
Sent By jgomez Date 2021-07-19 Time 17:32 Rev Time 0.00
Received By jgomez Date 2021-07-19 Time 15:03 Sent To  
Notes
2021-07-19 15:15:1307/23/21. SURVEY EMAILED BY SHARI DARPINO (OWNER).
 SURVEY SHOWS HOUSE FINISH FLOOR ELEVATION AT 12.81
 FEET. HOUSE WILL NEED TO BE RAISED TO 14.1 FEET MIN.
 ADDITION WILL NEED TO BE AT 14.1 FEET MIN. ALSO. JG
  
  
 BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21061567
  
 1- THIS IS A CONTRIBUTING HISTORIC HOUSE. THE PERMIT
 APPLICATION SPECIFIES INTERIOR DEMOLITION. PLANS
 SUBMITTED SHOW INTERIOR DEMOLITION AND THE DEMOLITION
 OF THE REAR ENCLOSED PORCH. IN ORDER TO PROTECT THE
 HISTORIC VALUE OF THIS HOUSE A DEMOLITION PERMIT WILL
 NOT BE ISSUED UNTIL THE ADDITION AND RECONSTRUCTION
 PLANS ARE APPROVED BY HISTORIC AND BUILDING REVIEW.
 (SEE PERMIT #21050921).
 SEC. 1201.1 FBC-EXISTING BUILDING.
  
 2- NEED A LICENSE CONTRACTOR TO APPLY FOR THIS PERMIT.
 OWNER OF THIS PROPERTY DOESN'T QUALIFY FOR THE
 OWNER/BUILDER EXEMPTION. OWNER MUST BE AN INDIVIDUAL
 NOT A CORPORATION IN ORDER TO QUALIFY FOR THE
 OWNER/BUILDER EXEMPTION. THE OWNER OF THIS PROPERTY IS
 SEF ACQUISITIONS LLC.
 SEC. 489.103(7)(C)
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-07-12 Cont ID  
Sent By jleahy Date 2021-07-12 Time 07:43 Rev Time 0.00
Received By jleahy Date 2021-07-12 Time 07:36 Sent To  
Notes
2021-07-12 07:47:57ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 PERMITS ARE FOR A DEMO BUT PLANS INCLUDE A REMODEL????
  
 PLEASE SUBMIT ONLY PLANS FOR DEMO OR A NEW APPLICATION
 FOR A REMODEL AND DEMO.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-07-24 Cont ID  
Sent By fmittner Date 2021-07-24 Time 11:59 Rev Time 0.00
Received By fmittner Date 2021-07-24 Time 11:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-26 Cont ID  
Sent By cthroop Date 2021-07-26 Time 10:46 Rev Time 0.00
Received By cthroop Date 2021-07-09 Time 12:18 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2021-07-23 Cont ID  
Sent By jgomez Date 2021-07-23 Time 17:34 Rev Time 0.00
Received By jgomez Date 2021-07-23 Time 16:19 Sent To  
Notes
2021-07-16 17:34:2507/23/21. SURVEY EMAILED BY SHARI DARPINO (OWNER).
 SURVEY SHOWS HOUSE FINISH FLOOR ELEVATION AT 12.81
 FEET. HOUSE WILL NEED TO BE RAISED TO 14.1 FEET MIN.
 ADDITION WILL NEED TO BE AT 14.1 FEET MIN. ALSO. JG
  
  
 1- FLOOD ZONE AE AND SUBSTANTIAL IMPROVEMENT.
 THE PROPOSED ADDITION IS GOING TO BE BUILT IN A AE
 FLOOD ZONE WITH A BASE FLOOD ELEVATION (BFE) OF 12.1
 FEET BASED ON NAVD 88.
 THE PROPOSED ADDITION IS CONSIDERED A SUBSTANTIAL
 IMPROVEMENT. THE ADDITION AND THE EXISTING HOUSE SHALL
 HAVE THE LOWEST FLOOR FINISHED ELEVATION ELEVATED TO OR
 ABOVE THE BASE FLOOD ELEVATION PLUS TWO FEET.
 THEREFORE, THE MIN. REQUIRED FINISHED FLOOR ELEVATION
 IS 14.1 FEET.
 NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR
 ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS
 ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH
 FLOOR ELEVATIONS FOR REVIEW.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT
 FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-07-19 Cont ID  
Sent By jgomez Date 2021-07-19 Time 15:18 Rev Time 0.00
Received By jgomez Date 2021-07-16 Time 17:42 Sent To  
Notes
***NONE***