Plan Review Details - Permit 21061333
Plan Review Stops For Permit 21061333
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-08-31 Cont ID  
Sent By rmcdouga Date 2021-08-31 Time 17:33 Rev Time 0.00
Received By rmcdouga Date 2021-08-31 Time 17:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-15 Cont ID  
Sent By rmcdouga Date 2021-07-15 Time 16:18 Rev Time 0.00
Received By rmcdouga Date 2021-07-15 Time 16:10 Sent To  
Notes
2021-07-15 16:10:19PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A DRAWING FOR THE STAIR GUARDS THAT CLEARLY
 SHOWS COMPLIANCE WITH THE FOLLOWING:
  
 R312.1.2 HEIGHT. REQUIRED GUARDS AT OPEN-SIDED WALKING
 SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR
 LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN
 HEIGHT AS MEASURED VERTICALLY ABOVE THE ADJACENT
 WALKING SURFACE OR THE LINE CONNECTING THE LEADING
 EDGES OF THE TREADS.
 EXCEPTIONS:
 1.GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A
 HEIGHT NOT LESS THAN 34 INCHES (864 MM) MEASURED
 VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF
 THE TREADS.
 2.WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON
 THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL BE
 NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38
 INCHES (965 MM) AS MEASURED VERTICALLY FROM A LINE
 CONNECTING THE LEADING EDGES OF THE TREADS.
  
 R312.1.3 OPENING LIMITATIONS. REQUIRED GUARDS SHALL NOT
 HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED
 GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4 INCHES
 (102 MM) IN DIAMETER.
 EXCEPTIONS:
 1.THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR,
 FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD,
 SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (153 MM)
 IN DIAMETER.
 2.GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE
 OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4-3/8 INCHES
 (111 MM) IN DIAMETER.
  
 2) THE NAME AND SIGNATURE OF THE PERSON THAT IS
 DESIGNING AND PREPARING THE DRAWING IS REQUIRED. FBC
 AMEND. 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-31 Cont ID  
Sent By rmcdouga Date 2021-08-31 Time 17:33 Rev Time 0.00
Received By rmcdouga Date 2021-08-10 Time 09:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-15 Cont ID  
Sent By rmcdouga Date 2021-07-15 Time 16:19 Rev Time 0.00
Received By rmcdouga Date 2021-06-23 Time 07:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-08-10 Cont ID  
Sent By lcrespo Date 2021-08-10 Time 11:11 Rev Time 0.00
Received By lcrespo Date 2021-08-10 Time 11:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-07-15 Cont ID  
Sent By rmcdouga Date 2021-07-15 Time 16:10 Rev Time 0.00
Received By rmcdouga Date 2021-07-15 Time 16:10 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved