Plan Review Details - Permit 21061234
| Plan Review Stops For Permit 21061234 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-11-16 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-11-16 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-29 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-29 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2021-07-29 14:31:43 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS SPECIFY THIS AS AN R-3 OCCUPANCY. THIS | | | BUILDING CONTAINS MORE THAN TWO DWELLING UNITS (CONDO) | | | AND IS CLASSIFIED AS AN R-2 OCCUPANCY. FBC CHAPTER 3 | | | | | | 2) THE WINDLOAD DATA INCORRECTLY SPECIFIES ASCE10-05. | | | THE 2020 FBC REFERENCES ASCE7-16 FOR WIND DESIGN. FBC | | | CHAPTER 35 | | | | | | 3) THE EXPOSURE CATEGORY IS SPECIFIED AS B. THE | | | EXPOSURE CATEGORY FOR THIS BUILDING SHOULD BE C. FBC | | | 1609 | | | | | | 4) SUBMIT THE SPECIFICATIONS WITH ALLOWABLE SPANS ALONG | | | WITH THE INSTALLATION INSTRUCTIONS FOR THE COMPOSITE | | | DECKING. FBC 1605 AND FBC AMEND. 107.1.2 | | | | | | 5) THE UNIFORM LIVE LOADS FOR THE STAIRS IS 100 PSF PER | | | FBC TABLE 1607.1. PLEASE SPECIFY THIS ON THE PLANS. | | | | | | 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2021-10-22 14:39:40 | FIRE PROVISO: | | | | | | PROVIDE FOR SAFE AND SECURE EXIT PATHWAY | | | WHERE APPLICABLE DURING CONSTRUCTION | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-07-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-30 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2021-07-30 10:56:37 | FIRE PROVISO: | | | | | | PROVIDE FOR SAFE AND SECURE EXIT PATHWAY | | | WHERE APPLICABLE DURING CONSTRUCTION | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-11-16 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-10-21 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-17 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-14 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-11-16 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-11-16 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-29 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-29 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2021-07-29 13:43:20 | I AM UNABLE TO VERIFY THE ARCHITECT'S DIGITAL | | | SIGNATURE. THE READER STATES SIGNATURE HAS AN INVALID | | | TIME STAMP. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-11-05 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-11-05 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-08-16 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-08-16 |
Time |
15:35 |
Sent To |
I |
|
| Notes |
|
|
|