Plan Review Details - Permit 21061233
Plan Review Stops For Permit 21061233
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-28 Cont ID  
Sent By rmcphers Date 2021-10-28 Time 10:00 Rev Time 0.00
Received By rmcphers Date 2021-10-28 Time 10:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-29 Cont ID  
Sent By rmcphers Date 2021-07-29 Time 11:17 Rev Time 0.00
Received By rmcphers Date 2021-07-29 Time 11:01 Sent To  
Notes
2021-07-29 11:17:29REPLACE BALCONY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW STAIR TREAD DEPTH TO COMPLY WITH FBC
 1011.5.2 (3.) IN GROUP R-3 OCCUPANCIES; WITHIN DWELLING
 UNITS IN GROUP R-2 OCCUPANCIES; AND IN GROUP U
 OCCUPANCIES THAT ARE ACCESSORY TO A GROUP R-3 OCCUPANCY
 OR ACCESSORY TO INDIVIDUAL DWELLING UNITS IN GROUP R-2
 OCCUPANCIES; THE MAXIMUM RISER HEIGHT SHALL BE 73/4
 INCHES (197 MM); THE MINIMUM TREAD DEPTH SHALL BE 10
 INCHES (254 MM);
 2) PLEASE SHOW SOLID RISERS PER FBC 1011.5.5.3 SOLID
 RISERS. EXCEPTIONS: 1.SOLID RISERS ARE NOT REQUIRED FOR
 STAIRWAYS THAT ARE NOT REQUIRED TO COMPLY WITH SECTION
 1009, PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT
 PERMIT THE PASSAGE OF A SPHERE WITH A DIAMETER OF 4
 INCHES (102 MM).

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-22 Cont ID  
Sent By pleduc Date 2021-10-22 Time   Rev Time 0.00
Received By pleduc Date 2021-10-22 Time 13:03 Sent To  
Notes
2021-10-22 13:08:13FIRE PROVISO:
  
 ENSURE A SAFE EXIT/MEANS OF EGRESS IS PROVIDED UNTIL
 CONSTRUCTION IS COMPLETED.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-15 Cont ID  
Sent By pleduc Date 2021-07-15 Time   Rev Time 0.00
Received By pleduc Date 2021-07-15 Time 14:14 Sent To  
Notes
2021-07-15 14:21:57FIRE PROVISO:
  
 ENSURE A SAFE EXIT/MEANS OF EGRESS IS PROVIDED UNTIL
 CONSTRUCTION IS COMPLETED.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-06 Cont ID  
Sent By lmarchan Date 2021-11-06 Time 17:35 Rev Time 0.00
Received By lmarchan Date 2021-10-21 Time 13:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-08-17 Cont ID  
Sent By rmcdouga Date 2021-08-17 Time 08:05 Rev Time 0.00
Received By rmcdouga Date 2021-07-14 Time 13:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-28 Cont ID  
Sent By rmcphers Date 2021-10-28 Time 10:01 Rev Time 0.00
Received By rmcphers Date 2021-10-28 Time 10:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-29 Cont ID  
Sent By rmcphers Date 2021-07-29 Time 11:17 Rev Time 0.00
Received By rmcphers Date 2021-07-29 Time 11:17 Sent To  
Notes
2021-07-29 11:22:12SIGNATURE REVIEW
 ADOBE READER SHOWS SIGNATURE AS INVALID -
 DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER
 OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR
 - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN
 ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By ajones Date 2021-11-05 Time 15:21 Rev Time 0.00
Received By ajones Date 2021-11-05 Time 15:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-08-16 Cont ID  
Sent By kalexand Date 2021-08-16 Time 16:09 Rev Time 0.00
Received By kalexand Date 2021-08-16 Time 16:09 Sent To I
Notes
***NONE***