| Plan Review Stops For Permit 21061231 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-17 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-17 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-29 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-29 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2021-07-29 14:46:49 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS SPECIFY THIS AS AN R-3 OCCUPANCY. THIS | | | BUILDING CONTAINS MORE THAN TWO DWELLING UNITS (CONDO) | | | AND IS CLASSIFIED AS AN R-2 OCCUPANCY. FBC CHAPTER 3 | | | | | | 2) THE WINDLOAD DATA INCORRECTLY SPECIFIES ASCE10-05. | | | THE 2020 FBC REFERENCES ASCE7-16 FOR WIND DESIGN. FBC | | | CHAPTER 35 | | | | | | 3) THE EXPOSURE CATEGORY IS SPECIFIED AS B. THE | | | EXPOSURE CATEGORY FOR THIS BUILDING SHOULD BE C. FBC | | | 1609 | | | | | | 4) SUBMIT THE SPECIFICATIONS WITH ALLOWABLE SPANS ALONG | | | WITH THE INSTALLATION INSTRUCTIONS FOR THE COMPOSITE | | | DECKING. FBC 1605 AND FBC AMEND. 107.1.2 | | | | | | 5) THE UNIFORM LIVE LOADS FOR THE STAIRS IS 100 PSF PER | | | FBC TABLE 1607.1. PLEASE SPECIFY THIS ON THE PLANS. | | | | | | 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-01 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2021-09-01 10:24:01 | FIRE PROVISO: | | | | | | PROVIDE FOR SAFE AND SECURE EXIT PATHWAY | | | WHERE APPLICABLE DURING CONSTRUCTION | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-07-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-30 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-07-30 10:58:33 | FIRE PROVISO: | | | | | | PROVIDE FOR SAFE AND SECURE EXIT PATHWAY | | | WHERE APPLICABLE DURING CONSTRUCTION | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-23 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-23 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-17 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-31 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-30 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-14 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-23 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-23 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-17 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-17 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2021-09-17 16:52:13 | THE PLANS HAVE NOT BEEN DIGITALLY SIGNED AND SEALED BY | | | THE ARCHITECT. ELECTRONICALLY SUBMITTED DRAWINGS ARE | | | REQUIRED TO HAVE THE ARCHITECT OR ENGINEER'S DIGITAL | | | SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT | | | THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. AFTER | | | THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT | | | THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S | | | ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO | | | BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF | | | THE SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | | 61G15 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-07-29 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-07-29 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2021-07-29 15:07:59 | I AM UNABLE TO VERIFY THE ARCHITECT'S DIGITAL | | | SIGNATURE. THE READER STATES SIGNATURE HAS AN INVALID | | | TIME STAMP. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-07-15 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-07-15 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|