Plan Review Details - Permit 21061179
| Plan Review Stops For Permit 21061179 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-18 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-18 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-31 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-31 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2021-07-31 07:19:01 | PLAN REVIEW BUILDING GENERATOR | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | NOTICE: COMMENTS FROM 1ST REVIEW HAVE NOT BEEN | | | ADDRESSED. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: PROVISO ON PLAN PAGE P-1. TOP OF STRUCTURAL GEN | | | PAD SHALL BE AT OR ABOVE FINISHED FLOOR ELEVATION. | | | | | | 1. THE GEN PAD DETAIL AND DESIGN WIND LOADS ARE BASED | | | ON THE 2010 FBC AND ASCE 7-10. PROVIDE STRUCTURAL | | | DETAIL AND WIND LOADS BASED ON THE 2020 FBC AND ASCE | | | 7-16. | | | | | | 2. GENERATOR LOCATION | | | R303.5.1 INTAKE OPENINGS: MECHANICAL AND GRAVITY | | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-09 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-03 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2021-07-09 10:37:53 | PLAN REVIEW BUILDING GENERATOR | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: PROVISO ON PLAN PAGE P-1. TOP OF STRUCTURAL GEN | | | PAD SHALL BE AT OR ABOVE FINISHED FLOOR ELEVATION. | | | | | | 1. THE GEN PAD DETAIL AND DESIGN WIND LOADS ARE BASED | | | ON THE 2010 FBC AND ASCE 7-10. PROVIDE STRUCTURAL | | | DETAIL AND WIND LOADS BASED ON THE 2020 FBC AND ASCE | | | 7-16. | | | | | | 2. GENERATOR LOCATION | | | R303.5.1 INTAKE OPENINGS: MECHANICAL AND GRAVITY | | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-28 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-28 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-18 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-03 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-31 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-15 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-13 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-18 |
Time |
06:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-18 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-18 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-31 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-31 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2021-07-31 07:22:13 | PLAN REVIEW SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | NOTICE: COMMENTS FROM 1ST REVIEW HAVE NOT BEEN | | | ADDRESSED. | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: STRUCTURAL GENERATOR PAD WITH DESIGN WIND LOADS AND | | | PLAN PAGE P-1. | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-09 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-03 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2021-07-09 10:26:17 | PLAN REVIEW SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: STRUCTURAL GENERATOR PAD WITH DESIGN WIND LOADS AND | | | PLAN PAGE P-1. | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-12 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-07-12 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-07-12 |
Time |
17:54 |
Sent To |
I |
|
| Notes |
|
|
|