Plan Review Details - Permit 21060874
Plan Review Stops For Permit 21060874
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-06-18 Cont ID  
Sent By cpuell Date 2021-06-18 Time 08:35 Rev Time 0.00
Received By cpuell Date 2021-06-18 Time 08:35 Sent To  
Notes
2021-06-18 08:35:54SUITE 135

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-06-17 Cont ID  
Sent By cpuell Date 2021-06-17 Time 15:38 Rev Time 0.00
Received By cpuell Date 2021-06-17 Time 15:38 Sent To  
Notes
2021-06-17 15:39:12REACHED OUT TO CUSTOMER WAITING TO HEAR BACK ON SUITE
 NUMBER.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 12:38 Rev Time 0.00
Received By shill Date 2021-09-10 Time 12:38 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-08-24 Cont ID  
Sent By rmcphers Date 2021-08-24 Time 14:38 Rev Time 0.00
Received By rmcphers Date 2021-08-24 Time 14:38 Sent To  
Notes
2021-08-24 14:38:48PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-07-16 Cont ID  
Sent By rmcphers Date 2021-07-16 Time 09:45 Rev Time 0.00
Received By rmcphers Date 2021-07-16 Time 09:45 Sent To  
Notes
2021-07-16 09:46:22PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 12:34 Rev Time 0.00
Received By shill Date 2021-09-10 Time 12:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-08-24 Cont ID  
Sent By rmcphers Date 2021-08-24 Time 13:51 Rev Time 0.00
Received By rmcphers Date 2021-08-24 Time 13:51 Sent To  
Notes
2021-08-24 14:30:32RESTAURANT BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) DRAWING G200 SHOWS THE ASSEMBLY AREA AS HAVING AN
 OCCUPANT LOAD OF 59 WHICH WILL REQUIRE 2 EXITS FROM
 THAT AREA - YOU CANNOT EXIT THRU A KITCHEN PER FBC
 1016.2 (5) EGRESS SHALL NOT PASS THROUGH KITCHENS,
 STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR
 PURPOSES.
 PLEASE RE CALCULATE THE ASSEMBLY AREA - FBC 1004.6
 FIXED SEATING.
 FOR AREAS HAVING FIXED SEATS AND AISLES, THE OCCUPANT
 LOAD SHALL BE DETERMINED BY THE NUMBER OF FIXED SEATS
 INSTALLED THEREIN. THE OCCUPANT LOAD FOR AREAS IN WHICH
 FIXED SEATING IS NOT INSTALLED, SUCH AS WAITING SPACES,
 SHALL BE DETERMINED IN ACCORDANCE WITH SECTION 1004.5
 AND ADDED TO THE NUMBER OF FIXED SEATS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-16 Cont ID  
Sent By rmcphers Date 2021-07-16 Time 10:18 Rev Time 0.00
Received By rmcphers Date 2021-07-15 Time 14:52 Sent To  
Notes
2021-07-16 10:18:55RESTAURANT BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) DRAWING G-100 - TOILET PAPER DISPENSER INSTALLATION
 DIMENSIONS ARE INCORRECT FBC A604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS.
 2) ACCESSIBLE RESTROOM MIRRORS SHOULD INDICATE THAT THE
 MAXIMUM HEIGHT IS TO THE "REFLECTIVE SURFACE" PER FBC
 A603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 3) DRAWING A-200 - ENLARGED RESTROOM PLAN - THE
 DIMENSIONS FOR THE TOILET REAR GRAB BAR ARE INCORRECT
 FBC A604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
 4) DRAWING A-300 - SLAB REPAIR SECTIONS SHOULD SHOW IF
 TERMITE TREATMENT IS REQUIRED FBC 1816.1.2
 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE
 PREVENTION, SOIL AREA DISTURBED AFTER INITIAL CHEMICAL
 SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL
 TREATMENT, INCLUDING SPACES BOXED OR FORMED.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-08-30 Cont ID  
Sent By jleahy Date 2021-08-30 Time 08:57 Rev Time 0.00
Received By jleahy Date 2021-08-27 Time 16:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-28 Cont ID  
Sent By jleahy Date 2021-06-28 Time 14:36 Rev Time 0.00
Received By jleahy Date 2021-06-28 Time 11:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-09-08 Cont ID  
Sent By pleduc Date 2021-09-08 Time   Rev Time 0.00
Received By pleduc Date 2021-09-08 Time 09:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-08-17 Cont ID  
Sent By pleduc Date 2021-08-17 Time   Rev Time 0.00
Received By pleduc Date 2021-08-17 Time 09:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-06-21 Cont ID  
Sent By pleduc Date 2021-06-21 Time   Rev Time 0.00
Received By pleduc Date 2021-06-18 Time 13:04 Sent To  
Notes
2021-06-18 13:16:45FIRE PROVISO:
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE EXISTING FIRE ALARM AND/OR FIRE SPRINKLER SYSTEMS
 SHALL BE MAINTAINED AND REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD, INCLUDING DEMO.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-07-09 Cont ID  
Sent By lcrespo Date 2021-07-09 Time 15:56 Rev Time 0.00
Received By lcrespo Date 2021-07-09 Time 15:56 Sent To  
Notes
2021-07-09 15:57:43GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 12:38 Rev Time 0.00
Received By shill Date 2021-09-07 Time 14:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-03 Cont ID  
Sent By lmarchan Date 2021-09-03 Time 10:30 Rev Time 0.00
Received By lmarchan Date 2021-08-16 Time 10:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-16 Cont ID  
Sent By rmcphers Date 2021-07-16 Time 10:21 Rev Time 0.00
Received By rmcphers Date 2021-06-17 Time 10:27 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2021-09-24 Cont ID  
Sent By shill Date 2021-09-24 Time 11:44 Rev Time 0.00
Received By shill Date 2021-09-13 Time 15:13 Sent To  
Notes
2021-09-24 11:45:09NO FEES DUE PER EMAIL FROM M.CHARLES, ROUTED EMAIL TO
 FILENET
  
2021-09-13 15:14:11IMPACT FEE QUESTIONNAIRE UPLOADED - EMAILED PBC IMPACT
 FEES OFFICE. CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-07-16 Cont ID  
Sent By rmcphers Date 2021-07-16 Time 10:20 Rev Time 0.00
Received By rmcphers Date 2021-07-16 Time 10:20 Sent To  
Notes
2021-07-16 10:21:02PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-08-24 Cont ID  
Sent By medwards Date 2021-08-24 Time 08:25 Rev Time 0.00
Received By medwards Date 2021-08-24 Time 08:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-06-25 Cont ID  
Sent By medwards Date 2021-06-25 Time 08:00 Rev Time 0.00
Received By medwards Date 2021-06-24 Time 16:36 Sent To  
Notes
2021-06-25 08:00:211ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21060874
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-600: PLEASE PROVIDE THE OUTDOOR AIR
 CALCULATIONS BASED ON THE 2020 FBC M 403.3.1.1 AND
 TABLE 403.3.1.1. THE KITCHEN OUTDOOR AIR CALCULATIONS
 HAVE CHANGED AND MUST BE INCLUDED IN THE CALCULATIONS.
  
 2) THE OUTDOOR AIR CALCULATIONS SHOWS A SQ.FT. OF 842
 FOR THE DINING ROOM BUT THE LIFE SAFETY SHOWS 869
 SQ,FT.
  
 3) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS.
  
 4) SHEET M-300: PLEASE EXPLAIN GX-1 AND IT?S FUNCTION
 IN THIS DESIGN. PLEASE PROVIDE SPECIFICATIONS.
  
 5) SHEET A-341: PLEASE PROVIDE THE SPECIFICATIONS FOR
 THE COMBINATION OVENS AND WHY A HOOD ISN?T REQUIRED.
 FBC M 507.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-02 Cont ID  
Sent By lcrespo Date 2021-09-02 Time 16:22 Rev Time 0.00
Received By lcrespo Date 2021-09-02 Time 16:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-09 Cont ID  
Sent By lcrespo Date 2021-07-09 Time 10:18 Rev Time 0.00
Received By lcrespo Date 2021-07-06 Time 10:59 Sent To  
Notes
2021-07-09 10:18:5107/09/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET G-100;
 A. UNDER TOILET AND PLUMBING FACILITIES, IT SHOWS THE
 GRAB BARS IN A VERTICAL POSITION. GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION PER THE 2020 FBC ACC
 SEC. 609.4.
  
 B. IN THE SAME DETAIL UNDER TOILET TISSUE DISPENSER
 LOCATION HAS A 12 INCHES MAX. THE TOILET PAPER
 DISPENSERS SHALL BE 7-INCHES MINIMUM AND 9-INCHES
 MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE
 CENTERLINE OF THE DISPENSER PER THE 2020 FBC ACC SEC.
 604.7.
  
 C. IN THE SAME DETAIL UNDER CLEARANCE REQUIREMENTS AT
 THE LAVATORY, THE 40-INCHES MAX SHALL BE TO THE
 REFLECTIVE PART OF THE MIRROR NEEDS TO BE THE OF
 40-INCHES TO THE REFLECTIVE SIDE PER THE 2020 FBC ACC
 SEC. 603.3.
  
 2. ON SHEET A-130, IT SHOWS THE WRONG CLEAR FLOOR SPACE
 FOR THE TOILETS. THE CLEAR FLOOR SPACE SHALL BE
 60-INCHES MINIMUM MEASURED PERPENDICULAR FROM THE
 SIDEWALL, AND 56-INCHES MINIMUM MEASURED PERPENDICULAR
 FROM THE REAR WALL PER THE 2020 FBC ACC. SEC. 604.3.1.
  
 3. ON SHEET A- 131 UNDER EQUIPMENT SCHEDULE "K";
 A. UNDER THE ICEMAKER SHALL BE EQUIPPED WITH AN IN-LINE
 VACUUM BREAKER THAT COMPLIES WITH ASSE 1024 PER THE
 2020 FBC SEC. 608.13.10. WOULD YOU PLEASE MAKE A NOTE
 ON THE REMARKS?
  
 B. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. WOULD YOU PLEASE MAKE A NOTE ON THE REMARKS?
  
 4. ON SHEET A-200 ON DETAIL 1 FOR ENLARGED RESTROOM
 PLAN;
 A. REMOVE THE 30-INCHES BY 48-INCHES SPACE IN FRONT OF
 THE WATER CLOSET AS IT IS NOT REQUIRED PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 B. THE DOORS ARE IN THE CLEAR FLOOR SPACE OF THE LAVS.
 PLEASE SHOW THE TURNING SPACE DIAMETER- SPACE SHALL BE
 A SPACE OF 60 INCHES DIAMETER MINIMUM PER THE 2020 FBC
 ACC SEC. 304.3.
  
 C. PLEASE ONLY SHOW ONE CLEAR FLOOR SPACE IN FRONT OF
 LAVS, AS THERE ARE THREE DIFFERENT HATCH MARKS, FOR
 CLARITY PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 D. THE REAR GRAB BAR SAYS 11-INCHES TO CENTER. WOULD
 YOU PLEASE CORRECT IT TO 12-INCHES PER THE 2020 ACC
 SEC. 604.5.2 REAR WALL?
  
 E. SEATS OF WATER CLOSETS SHALL BE OPEN-FRONT TYPE PER
 2020 FBC P 425.3 WATER CLOSET SEATS
  
 5. ON SHEET A-200 ON DETAIL 2, 5, 8, AND 9 ALL RR
 ELEVATION;
 A. THE BOTTOM ON THE LAV SHALL BE A MINIMUM OF
 27-INCHES KNEE CLEARANCE PER THE 2020 FBC SEC. 306.3.
  
 B. THE MIRROR'S REFLECTIVE PART NEEDS TO BE 40-INCHES
 TO THE REFLECTIVE SIDE PER THE 2017 FBC ACC SEC. 603.3.
  
 6. ON SHEET A-200 ON DETAIL 3, 6, AND 9, ALL RR
 ELEVATION ON ANY OF THE DETAILS SHOW THE TOILET SEATS
 NEED TO BE 17-INCHES TO 19-INCHES MAXIMUM MEASURED TO
 THE TOP OF THE SEAT PER THE 2020 FBC ACC SEC. 604.4
 SEATS.
  
 7. ON SHEET A-300, PLEASE PROVIDE DETAIL ON HOW GRAB
 BARS REINFORCEMENT IN WALLS. WOULD YOU PLEASE SHOW THE
 MINIMUM AND MAXIMUM DISTANCE FROM FLOOR PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS?
  
 8. ON SHEET P-100, UNDER GENERAL NOTES #17, IT REFERS
 TO THE 2017 FBC 6TH EDITION. WOULD YOU PLEASE CORRECT
 TO CURRENT EDITION PER THE WPB AMENDMENTS TO FBC 102.3
 APPLICATION OF REFERENCES?
  
 9. ON SHEET P-101 UNDER SCOPE OF WORK #A, IT REFERS TO
 THE 2017 FBC 6TH EDITION. WOULD YOU PLEASE CORRECT TO
 CURRENT EDITION PER THE WPB AMENDMENTS TO FBC 102.3
 APPLICATION OF REFERENCES?
  
 10. ON SHEET P-101 AND G-300, IT REFERS TO GAS AND NOT
 ISOMETRIC GAS SIZING, TABLES AND APPLIANCE MANUFACTURE
 SPECIFICATION WAS SUPPLIED. YOU MAY CHOOSE TO HAVE A
 GAS REVIEW DONE THIS TIME AND ADDRESS THE COMMENTS
 ABOVE. THIS WILL HAVE THE GAS APPROVE FOR A SUB PERMIT,
 OR IF YOU DECIDED NOT TO ADDRESS THESE COMMENTS, PLEASE
 PUT A NOTE ON THE PLANS ( A SEPARATE PERMIT BY A
 LICENSED CONTRACTOR FOR THE GAS SYSTEM). AN N WILL BE
 PLACED ON THIS REVIEW, WHICH STANDS FOR NOT REQUIRED
 BUT, A SUB PERMIT WON'T BE ISSUED UNIT A REVIEW IS DONE
 FOR THAT SUB PERMIT, SO PLEASE BE ADVISED ON THIS
 PROCEDURE.
  
 11. ON SHEET P-301, IT SHOWS A BOTTLE FILLER. DOES IT
 REQUIRE TO BE UNDER THE ACCESSIBILITY CODE AND HAVE A
 HIGH AND LOW WITH CLEAR FLOOR SPACE? WOULD YOU PLEASE
 CLARIFY PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS?
  
 12. ON SHEET P-302, UNDER REFERENCE NOTE #4, THE
 ICEMAKER SHALL BE EQUIPPED WITH AN IN-LINE VACUUM
 BREAKER THAT COMPLIES WITH ASSE 1024 PER THE 2020 FBC
 SEC. 608.13.10.
  
 13. ON SHEET P-500;
 A. SIZES ARE MISSING ON VERTICAL AND HORIZONTAL PIPES;
 TOO MANY TO MENTION. WOULD YOU PLEASE CORRECT PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS?
  
 B. THE BOTTLE FILLER, ICEMAKER, WATER HEATER DRAIN, AND
 LAVS ARE NOT ALLOWED TO GO INTO THE GREASE INTERCEPTOR.
 PLEASE REFER TO 64E-6, FLORIDA ADMINISTRATIVE CODE FOR
 PROPER DISPLACEMENT TO THE SANITARY OR GREASE
 INTERCEPTOR PER THE 64E-6. STANDARDS FOR ONSITE SEWAGE
 TREATMENT AND DISPOSAL SYSTEMS.
  
 14. ON SHEET P-501;
 A. PLEASE PROVIDE A SHUTOFF VALVE ON BOTH SIDES OF THE
 RECIRCULATING PUMP PER THE 2020 FBC SEC. P 606.2 #3.
 ALSO, SHOW ON HEATER DETAIL P-700 #11.
  
 B. PLEASE PROVIDE A HAMMER ARRESTOR ON BOTTLE FILLER
 AND ANY OTHER QUICK CLOSING VALVE PER THE 2020 FBC SEC.
 604.9.
  
 C. PLEASE SHOW THE ATMOSPHERIC-TYPE VACUUM BREAKERS ON
 THE BOTTOM FEED HEATER TANK PER THE 2020 FBC SEC.
 608.14.6.
  
 D. THE RECIRCULATING MANIFOLD TO THE HOT WATER LINES
 MAY NEED TO BE CLOSER TO THE OUTLET SOURCE; PLEASE
 REFER TO THE 2020 FBC ENERGY CODE TABLE C404.5.1.
  
 15. ON SHEET P-600 UNDER EQUIPMENT SCHEDULE;
 A. ICEMAKER AND COFFEE MAKER SHALL BE EQUIPPED WITH AN
 IN-LINE VACUUM BREAKER THAT COMPLIES WITH ASSE 1024 PER
 THE 2020 FBC SEC. 608.13.10. WOULD YOU PLEASE MAKE A
 NOTE ON THE REMARKS?
  
 B. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. WOULD YOU PLEASE MAKE A NOTE ON REMARKS?
  
 16. ON SHEET P-700
 A. PLEASE PROVIDE DETAILS 1, 5, AND 8 FOR THE UL USE
 FOR THE SYSTEM AND THE FIRE-RATED ASSEMBLY PER THE WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 B. PLEASE PROVIDE DETAIL FOR THE MULTIPLE-COMPARTMENT
 SINK SHOWING THE DISCHARGE INDEPENDENTLY TO A WASTE
 RECEPTOR PER THE 2020 FBC P 802.1.1.
  
 WOULD YOU PLEASE PLACE A NOTE ON A PLAN THAT THE GREASE
 INTERCEPTOR IS UNDER A DIFFERENT PERMIT WITH SIZING
 CALCULATION?
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-09-10 Cont ID  
Sent By shill Date 2021-09-10 Time 12:35 Rev Time 0.00
Received By shill Date 2021-09-10 Time 12:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-24 Cont ID  
Sent By rmcphers Date 2021-08-24 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2021-08-24 Time 14:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-25 Cont ID  
Sent By medwards Date 2021-06-25 Time 08:24 Rev Time 0.00
Received By medwards Date 2021-06-25 Time 08:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-09-03 Cont ID  
Sent By eschneid Date 2021-09-03 Time 09:44 Rev Time 0.25
Received By eschneid Date 2021-09-03 Time 09:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-07-13 Cont ID  
Sent By eshneide Date 2021-07-13 Time 16:16 Rev Time 0.75
Received By eschneid Date 2021-07-13 Time 13:31 Sent To  
Notes
2021-07-13 16:16:03FAILED
  
 1) SHEET A-000 SITE PLAN SHOWS TWO DEDICATED PARKING
 SPACES BY THE REAR ENTRANCE. THIS IS NOT PERMITTED AS
 THE AREA WHERE THE PARKING SPACES ARE SHOWN IS A
 REQUIRED LOADING AREA. THESE SPACES MUST BE REMOVED
 FROM THE SITE PLAN.
  
 2) THE PATIO PLAN SHOWN ON SHEET A-032 IS NOT APPROVED
 AS PART OF THIS PERMIT. IT REQUIRES SEPARATE APPROVAL
 UNDER A SIDEWALK CAFE PERMIT APPLICATION. PLEASE NOTE
 THAT STAFF HAS PERFORMED A CURSORY REVIEW OF THE PATIO
 LAYOUT AND IS DOES NOT COMPLY WITH THE CITY'S SIDEWALK
 CAFE REGULATIONS. PLEASE CONTACT ANA MARIA APONTE, CITY
 URBAN DESIGNER, AT (561) 822-1439 FOR FURTHER GUIDANCE.
  
 3) JUNCTION BOXES, CONDUIT, AND ANY OTHER ITEMS
 REQUIRED TO PROVIDE POWER TO SIGNAGE MAY NOT BE VISIBLE
 TO THE PUBLIC. THESE NEED TO BE LOCATED WITHIN THE
 CEILING IF OUTSIDE OF THE TENANT SPACE.
  
 4) ALL SIGNAGE VISIBLE TO THE EXTERIOR OF THE BUILDING
 REQUIRES PERMITS. THIS INCLUDES WHAT APPEARS TO BE THE
 SIGN HANGING INSIDE THE WINDOW AND THE WINDOW GRAPHICS.
 THE ENTRY FLOOR SIGN IS WITHIN THE STOREFRONT, SO IT
 DOES NOT REQUIRE A SEPARATE PERMIT. PLEASE NOTE THAT
 THE BLADE SIGN LOCATION SHOWN ON THE PLANS IS OUTSIDE
 OF THE LEASE LINE AND THEREFORE NOT PERMITTED AT THAT
 LOCATION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  