|
 |
 |
 |
 |
 |
Plan Review Details - Permit 21060805
| Plan Review Stops For Permit 21060805 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-02 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-02 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-07-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-07-02 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-07-02 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2021-07-02 13:59:04 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | | FL2533-R25 IS INCOMPLETE, PROVIDE THE FOLLOWING | | | ADDITIONAL INFORMATION: COVER SHEET | | | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE | | | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL | | | INFORMATION ABOUT THE PRODUCT). SECOND REQUEST. | | | 2.FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R25 SELECTED SYSTEM NO. W-34 DO NOT | | | MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN | | | PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM | | | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE | | | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR | | | ZONE 3 AS PER LIMITATIONS: 5.7.2. ALL APPLICABLE | | | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON | | | THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS | | | NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING. (YOU MAY WANT TO CONSIDER | | | USING SYSTEM NO. W-42 OR W-45 OR W-54 OR W-55.) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-28 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-28 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2021-06-28 12:46:54 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | | FL2533-R25 IS INCOMPLETE, PROVIDE THE FOLLOWING | | | ADDITIONAL INFORMATION: COVER SHEET | | | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE | | | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL | | | INFORMATION ABOUT THE PRODUCT). | | | 2.FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R25 SELECTED SYSTEM NO. W-33 DO NOT | | | MEET THE EXPOSURE CATEGORY C; ZONE 2 MINIMUM DESIGN | | | PRESSURE REQUIREMENT OF -79.38 OR ZONE 3 MINIMUM DESIGN | | | PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM | | | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE | | | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR | | | ZONES 2 & 3 AS PER LIMITATIONS: 5.7.2. ALL APPLICABLE | | | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON | | | THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS | | | NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-23 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-23 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2021-06-23 11:30:57 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R24 HAS BEEN REVISED TO FL2533-R25. | | | PLEASE PROVIDE A COMPLETE SET OF PRODUCT APPROVALS. | | | INCLUDE COVER PAGE, EVALUATION REPORTS AND INSTALLATION | | | INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS | | | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE | | | PRODUCT APPROVAL DRAWINGS. | | | 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | | ROOF HEIGHT. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-07-02 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-30 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-28 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-24 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-23 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-23 |
Time |
05:41 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |