Plan Review Details - Permit 21060673
Plan Review Stops For Permit 21060673
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-10-08 Cont ID  
Sent By cpuell Date 2021-10-08 Time 13:57 Rev Time 0.00
Received By cpuell Date 2021-10-08 Time 13:57 Sent To  
Notes
2021-10-08 14:01:01ABOVE GARAGE HABITABLE SPACE GIVEN THE ADDRESS OF 7113
 S FLAGLER DR

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-09-01 Cont ID  
Sent By cpuell Date 2021-09-01 Time 13:30 Rev Time 0.00
Received By cpuell Date 2021-09-01 Time 13:30 Sent To  
Notes
2021-09-01 13:30:31COMMENTS NOT ADDRESSED.
  
 PLEASE HAVE OWNER COORDINATE WITH [email protected] OR
 CALL 561-805-6659 FOR THE LIVABLE SPACE TO BE GIVEN AN
 ADDRESS FOR GUEST SUITE ABOVE THE PROPOSED GARAGE. ALL
 ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER
 HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY
 ADDRESS NUMBER.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-06-21 Cont ID  
Sent By cpuell Date 2021-06-21 Time 17:06 Rev Time 0.00
Received By cpuell Date 2021-06-21 Time 17:06 Sent To  
Notes
2021-06-21 17:07:20PLEASE HAVE OWNER COORDINATE WITH [email protected] OR
 CALL 561-805-6659 FOR THE LIVABLE SPACE TO BE GIVEN AN
 ADDRESS FOR GUEST SUITE ABOVE THE PROPOSED GARAGE. ALL
 ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER
 HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY
 ADDRESS NUMBER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2021-12-28 Cont ID  
Sent By cthroop Date 2021-12-28 Time 08:22 Rev Time 0.00
Received By cthroop Date 2021-12-28 Time 08:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2021-12-04 Cont ID  
Sent By cthroop Date 2021-12-04 Time 09:44 Rev Time 0.00
Received By cthroop Date 2021-12-04 Time 09:11 Sent To  
Notes
2021-12-01 09:57:43BUILDING REVIEW APPROVED PENDING APPROVAL OF ELEVATION
 CERTIFICATE
 AN INTERNAL PEER REVIEW AND APPROVAL OF CONSTRUCTION
 DRAWING ELEVATION CERTIFICATE IS REQUIRED. CT
 PROVISO ON PG. A-1-1: FLOOD VENTS ARE NOT REQUIRED FOR
 THE CABANA. DESIGNER WILL REMOVE VENTS UPON REVISION.
 REDLINED VENTS. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2021-11-09 Cont ID  
Sent By cthroop Date 2021-11-09 Time 15:52 Rev Time 0.00
Received By cthroop Date 2021-11-09 Time 15:52 Sent To  
Notes
2021-11-09 15:53:51PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 4TH REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 NOTICE:
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE, REVIEWED
 AND APPROVED, IS REQUIRED PRIOR TO PERMIT. SEE COMMENTS
 UNDER NFIP REVIEW.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-10-29 Cont ID  
Sent By cthroop Date 2021-10-29 Time 16:02 Rev Time 0.00
Received By cthroop Date 2021-10-29 Time 14:24 Sent To  
Notes
2021-10-29 16:06:04PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 3RD REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 COMMENT FROM 1ST REVIEW NOT ADDRESSED. SEE #2 BELOW.
  
 2. PROVIDE SOILS REPORT. (NOT ADDRESSED)
 FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL
 BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6.
  
 NOTICE:
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE, REVIEWED
 AND APPROVED, IS REQUIRED PRIOR TO PERMIT.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-10-04 Cont ID  
Sent By cthroop Date 2021-10-04 Time 07:46 Rev Time 0.00
Received By cthroop Date 2021-10-01 Time 13:59 Sent To  
Notes
2021-10-04 07:50:16PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 NOTICE: A SEPERATE PERMIT IS REQUIRED FOR FREE STANDING
 GARAGE. (NOT CORRECTED)
 NOTICE: A SEPERATE PERMIT IS REQUIRED FOR SITE WALLS.
 (CORRECTED-PERMIT ISSUED FOR SITE WALLS)
  
 1. PROVIDE AN UPDATED BOUNDRY LINE SURVEY. (NOT
 ADDRESSED)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE SOILS REPORT. (NOT ADDRESSED)
 FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL
 BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6.
  
 3. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXT.
 DOORS. (CORRECTED-PRODUCT APPROVALS SHALL BE DEFERRED)
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 DEFERRAL OPTION:
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 4. ROOF PLAN PAGE A-3.1 STATES ROOF ASSEMBLY INSULATION
 R VALUE AS R-30. ENERGY SUBMITTAL STATES ROOF ASSEMBLY
 R VALUE AS R-20. (CORRECTED)
 PLEASE CLARIFY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 5. PROVIDE THE ICC-ES REPORT FOR THE PROPOSED ICYNENE
 SPRAY FOAM INSULATION. (SEE PROVISO ON PLAN PAGE A-3.1)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-27 Cont ID  
Sent By cthroop Date 2021-07-27 Time 08:19 Rev Time 0.00
Received By cthroop Date 2021-07-24 Time 07:11 Sent To  
Notes
2021-07-27 08:28:02PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: A SEPERATE PERMIT IS REQUIRED FOR FREE STANDING
 GARAGE.
 NOTICE: A SEPERATE PERMIT IS REQUIRED FOR SITE WALLS.
  
 1. PROVIDE AN UPDATED BOUNDRY LINE SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE SOILS REPORT.
 FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL
 BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6.
  
 3. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXT.
 DOORS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 DEFERRAL OPTION:
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 4. ROOF PLAN PAGE A-3.1 STATES ROOF ASSEMBLY INSULATION
 R VALUE AS R-30. ENERGY SUBMITTAL STATES ROOF ASSEMBLY
 R VALUE AS R-20.
 PLEASE CLARIFY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 5. PROVIDE THE ICC-ES REPORT FOR THE PROPOSED ICYNENE
 SPRAY FOAM INSULATION.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-09-29 Cont ID  
Sent By jleahy Date 2021-09-29 Time 16:22 Rev Time 0.00
Received By jleahy Date 2021-09-29 Time 16:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-07-01 Cont ID  
Sent By jleahy Date 2021-07-01 Time 17:16 Rev Time 0.00
Received By jleahy Date 2021-07-01 Time 17:07 Sent To  
Notes
2021-07-01 17:39:10ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) GARAGE PANEL TO HAVE MAIN BREAKER INSTALLED PER
 225.33
  
 225.33 MAXIMUM NUMBER OF DISCONNECTS. (A) GENERAL. THE
 DISCONNECTING MEANS FOR EACH SUPPLY PERMITTED BY 225.30
 SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR SIX
 CIRCUIT BREAKERS MOUNTED IN A SINGLE ENCLOSURE, IN A
 GROUP OF SEPARATE ENCLOSURES, OR IN OR ON A SWITCHBOARD
 OR SWITCHGEAR. THERE SHALL BE NO MORE THAN SIX
 DISCONNECTS PER SUPPLY GROUPED IN ANY ONE LOCATION.
  
 2) GARAGE PANEL TO HAVE A GROUNDING ELECTRODE SYSYEM
 INSTALLED 250.33
  
 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY A FEEDER(S)
 OR BRANCH CIRCUIT(S). (A) GROUNDING ELECTRODE.
 BUILDING(S) OR STRUCTURE(S) SUPPLIED BY FEEDER(S) OR
 BRANCH CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR
 GROUNDING ELECTRODE SYSTEM INSTALLED IN ACCORDANCE WITH
 PART III OF ARTICLE 250. THE GROUNDING ELECTRODE
 CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE WITH
 250.32(B) OR (C). WHERE THERE IS NO EXISTING GROUNDING
 ELECTRODE, THE GROUNDING ELECTRODE(S) REQUIRED IN
 250.50 SHALL BE INSTALLED.
  
 3) FOYER TO HAVE OUTLETS INSTALLED PER 210.52 (I)
  
 210.52(I) FOYERS. FOYERS THAT ARE NOT PART OF A HALLWAY
 IN ACCORDANCE WITH 210.52(H) AND THAT HAVE AN AREA THAT
 IS GREATER THAN 5.6 M2 (60 FT2) SHALL HAVE A
 RECEPTACLE(S) LOCATED IN EACH WALL SPACE 900 MM (3 FT)
 OR MORE IN WIDTH. DOORWAYS, DOOR-SIDE WINDOWS THAT
 EXTEND TO THE FLOOR, AND SIMILAR OPENINGS SHALL NOT BE
 CONSIDERED WALL SPACE.
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-09-17 Cont ID  
Sent By lcrespo Date 2021-09-17 Time 08:50 Rev Time 0.00
Received By lcrespo Date 2021-09-17 Time 08:49 Sent To  
Notes
2021-09-17 08:53:3709/17/21 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-07-06 Cont ID  
Sent By lcrespo Date 2021-07-06 Time 17:06 Rev Time 0.00
Received By lcrespo Date 2021-07-06 Time 17:06 Sent To  
Notes
2021-07-06 17:06:5007/06/21 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET P3.1;
 A. THE UNDERGROUND GAS NEED TO HAVE A VENT ON ONE SIDE
 PER THE 2020 G2415.8.1 CONDUIT WITH ONE END TERMINATING
 OUTDOORS.
  
 B. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION PER THE 2020 FBC RES. SEC. G2421.1.
  
 C. THE SYSTEM DOES NOT HAVE THE TOTAL BTU'S; THE FUTURE
 IS NOT SHOWN; PLEASE LIST THE BTU LOAD OF EACH
 APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER
 TO THE 2020 FBC RES. SEC. G2413. LIST THE BTU LOAD OF
 EACH APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM.
 REFER TO THE 2020 FBC RES. SECS. G2413.3, G2413.4, AND
 TABLES G2413.4 (1) THROUGH G2413.4 (21).
  
 D. SUBMIT MANUFACTURER?S SPECIFICATION
 SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT
 (FUTURE GENERATOR, FIRE PIT, TANK-LESS, AND
 RANGE/OVEN)TO VERIFY COMPLIANCE WITH 2020 FBC RES. SEC.
 G2408.1.
  
 E. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT
 SHALL BE ONSITE AT THE INSPECTION TIME PER THE 2020 FBC
 RES. SEC. G2413.2 AND G2404.3.
  
 F. PLEASE SHOW AND LABEL ALL UNIONS IN FRONT OF
 REGULATOR 1' OF EITHER SIDE PER THE 2020 FBC RES. SEC
 G2421.2.
  
 G. PLEASE SHOW AND LABEL THE SHUTOFF VALVE ON GAS
 ISOMERIC PER THE 2020 FBC RES. SEC. G2420.5.
  
 H. THE SHUT OFF INSIDE SHALL BE ACCESSIBLE WITHOUT
 MOVING THE EQUIPMENT PER THE 2020 FBC SEC. G2403 (202)
 GD, ACCESS.
  
 I. PLEASE SHOW AND LABEL ALL DRIP LEGS ON EQUIPMENT
 INSTALLED, EXCEPT FOR APPLIANCES, RANGE, DRYERS & OD
 GRILLS PER THE 2020 FBC RES. SEC. G2419.2.
  
 J. THE LOCATION OF THE WATER HEATER SHALL COMPLY WITH
 THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1. J. ON THE HOUSE
 PLAN, SHOW THE LOCATION OF THE TANK-LESS WATER HEATER
 AND THE LOCATION AND DISTANCE OF ANY OPERABLE DOORS OR
 WINDOWS IN RELATION TO THE WATER HEATER. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 K. A NOTE MAY BE PLACED ON PLANS. L. PIPES NOT IN
 CONDITION SPACE NEED TO BE INSULATED WITH A MINIMUM R-3
 PER THE 2020 FBC SEC. RE 403.5.3.
  
 L. IF TANK-LEES UNITS ARE CONDENSATION, THEY NEED TO BE
 1' AWAY FROM STRUCTURE PER THE 2020 FBC SEC. R318.5. A
 NOTE MAY BE PLACED ON PLANS.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2021-12-29 Cont ID  
Sent By aoliver Date 2021-12-29 Time 13:34 Rev Time 0.00
Received By aoliver Date 2021-12-28 Time 17:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-12-04 Cont ID  
Sent By cthroop Date 2021-12-04 Time 09:48 Rev Time 0.00
Received By cthroop Date 2021-11-15 Time 14:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-11-09 Cont ID  
Sent By cthroop Date 2021-11-09 Time 16:13 Rev Time 0.00
Received By cthroop Date 2021-11-02 Time 06:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-29 Cont ID  
Sent By cthroop Date 2021-10-29 Time 16:07 Rev Time 0.00
Received By cthroop Date 2021-10-14 Time 07:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-04 Cont ID  
Sent By cthroop Date 2021-10-04 Time 08:04 Rev Time 0.00
Received By cthroop Date 2021-09-01 Time 10:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-27 Cont ID  
Sent By cthroop Date 2021-07-27 Time 08:55 Rev Time 0.00
Received By cthroop Date 2021-06-23 Time 06:07 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-01-05 Cont ID  
Sent By cpuell Date 2022-01-05 Time 08:35 Rev Time 0.00
Received By cpuell Date 2021-12-28 Time 17:32 Sent To  
Notes
2022-01-03 13:56:55RECEIPT MU-2021-059934 - $6796.18 PAID
2021-12-28 17:33:01IMPACT FEE QUESTIONNAIRE UPLOADED - EMAILED PBC IMPACT
 FEE OFFICE. CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-07-27 Cont ID  
Sent By cthroop Date 2021-07-27 Time 07:57 Rev Time 0.00
Received By cthroop Date 2021-07-27 Time 07:57 Sent To  
Notes
2021-07-27 07:58:05PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-09-02 Cont ID  
Sent By medwards Date 2021-09-02 Time 09:24 Rev Time 0.00
Received By medwards Date 2021-09-02 Time 09:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-06-29 Cont ID  
Sent By medwards Date 2021-06-29 Time 15:18 Rev Time 0.00
Received By medwards Date 2021-06-29 Time 15:18 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 6 Status P Date 2021-12-28 Cont ID  
Sent By rmcphers Date 2021-12-28 Time 07:38 Rev Time 0.00
Received By rmcphers Date 2021-12-28 Time 07:38 Sent To  
Notes
2021-12-28 07:39:26PEER REVIEW COMPLETE

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 5 Status F Date 2021-12-04 Cont ID  
Sent By cthroop Date 2021-12-04 Time 09:47 Rev Time 0.00
Received By cthroop Date 2021-12-04 Time 09:11 Sent To  
Notes
2021-11-18 17:09:13NFIP REVIEW APPROVED PENDING INTERNAL PEER REVIEW AND
 APPROVAL OF CONSTRUCTION DRAWING ELEVATION CERTIFICATE.
 CT
 PROVISO ON PG. A-4.2: FLOOD VENTS ARE NOT REQUIRED FOR
 THE CABANA. DESIGNER WILL REMOVE VENTS UPON REVISION.
 REDLINED VENTS. CT

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 4 Status F Date 2021-11-09 Cont ID  
Sent By cthroop Date 2021-11-09 Time 15:54 Rev Time 0.00
Received By cthroop Date 2021-11-09 Time 15:54 Sent To  
Notes
2021-11-09 16:03:51PLAN REVIEW / NFIP
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16
  
 4TH REVIEW
  
  
 NOTICE: PROVIDE A CONSTRUCTION DRAWING ELEVATION
 CERTIFICATE.
  
 PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD
 ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD.
 MAIN DWELLING UNIT IS LOCATED IN FLOOD ZONE AE 7 . BFE
 IS 7.0' NAVD. DFE SHALL NOT BE LESS THAN 9.0 FEET NAVD.
 FREE STANDING CABANA/GARAGE IS LOCATED IN FLOOD ZONE AE
 6. BFE IS 6.0' NAVD. DFE SHALL NOT BE LESS THAN 8.0'
 NAVD.
  
  
 NOTICE:
  
 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
 SUBMIT TO BUILDING DEPARTMENT FOR REVIEW.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  
  
 NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES
 ARE REQUIRED FOR THE FREE STANDING CABANA/GARAGE. FLOOD
 ZONE IS AE 6. BFE IS 6.0' NAVD. DFE SHALL BE NOT LESS
 THAN 8.0' NAVD.
  
 NOTICE: PROVISO ON PLAN PAGE S-1.1. A SEPERATE PERMIT
 IS REQUIRED FOR FREE STANDING GARAGE.
  
 NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC
  
 NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC
  
 NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER
 INSPECTION HOLDS REMOVED.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status F Date 2021-10-29 Cont ID  
Sent By cthroop Date 2021-10-29 Time 16:06 Rev Time 0.00
Received By cthroop Date 2021-10-29 Time 14:24 Sent To  
Notes
2021-10-29 16:07:55PLAN REVIEW / NFIP
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16
  
 3RD REVIEW
  
 COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE
 BELOW.
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
  
 PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD
 ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD.
 DESIGN FLOOD ELEVATION OF MAIN DWELLING UNIT SHALL NOT
 BE LESS THAN 9.0 FEET NAVD. FREE STANDING GARAGE,
 LOCATED IN SFHA W/BFE 6.0' NAVD.
  
  
 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
 SUBMIT TO BUILDING DEPARTMENT FOR REVIEW.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  
  
 NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES
 ARE REQUIRED FOR FREE STANDING GARAGE. BFE 6.0' DFE
 9.0' NAVD.
  
 NOTICE: PROVISO ON PLAN PAGE S-1.1
  
 NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC
  
 NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC
  
 NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER
 INSPECTION HOLDS REMOVED.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2021-10-04 Cont ID  
Sent By cthroop Date 2021-10-04 Time 08:01 Rev Time 0.00
Received By cthroop Date 2021-10-01 Time 13:59 Sent To  
Notes
2021-10-04 08:04:46PLAN REVIEW / NFIP
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16
  
 2ND REVIEW
  
 COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE
 BELOW.
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
  
 PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD
 ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD.
 DESIGN FLOOD ELEVATION OF MAIN DWELLING UNIT SHALL NOT
 BE LESS THAN 9.0 FEET NAVD. FREE STANDING GARAGE,
 LOCATED IN SFHA W/BFE 6.0' NAVD.
  
  
 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
 SUBMIT TO BUILDING DEPARTMENT FOR REVIEW.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  
  
 NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES
 ARE REQUIRED FOR FREE STANDING GARAGE. BFE 6.0' DFE
 9.0' NAVD.
  
 NOTICE: PROVISO ON PLAN PAGE S-1.1
  
 NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC
  
 NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC
  
 NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER
 INSPECTION HOLDS REMOVED.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2021-07-27 Cont ID  
Sent By cthroop Date 2021-07-27 Time 08:05 Rev Time 0.00
Received By cthroop Date 2021-07-24 Time 07:16 Sent To  
Notes
2021-07-24 07:17:17PLAN REVIEW / NFIP
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
  
 PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD
 ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD.
 DESIGN FLOOD ELEVATION SHALL BE NOT LESS THAN 9.0 FEET
 NAVD.
  
  
 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
 SUBMIT TO BUILDING DEPARTMENT FOR REVIEW.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  
  
 NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES
 ARE REQUIRED FOR FREE STANDING GARAGE. BFE 6.0' DFE
 9.0' NAVD.
  
 NOTICE: PROVISO ON PLAN PAGE S-1.1
  
 NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC
  
 NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC
  
 NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER
 INSPECTION HOLDS REMOVED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-17 Cont ID  
Sent By lcrespo Date 2021-09-17 Time 08:22 Rev Time 0.00
Received By lcrespo Date 2021-09-17 Time 08:22 Sent To  
Notes
2021-09-17 08:22:2109/17/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-06 Cont ID  
Sent By lcrespo Date 2021-07-06 Time 16:19 Rev Time 0.00
Received By lcrespo Date 2021-07-06 Time 16:19 Sent To  
Notes
2021-07-06 16:19:2407/06/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET P1.1 IN THE KITCHEN IT THERE IS A BAR SINK
 SHOWN AND LABELED BSK. THERE IS NO DRAIN TO, NOT IN
 USE; PLEASE DELETE OR SHOW ON LAYOUT AND ISOMETRIC PER
 THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION
 ON CONSTRUCTION DOCUMENTS.
  
 2. THE FUTURE CAP OFF SHOWING A WASHING MACHINE WILL
 REQUIRE THE VALVES TO BE ACCESSIBLE WITHOUT MOVING OF
 THE UNITS AND WITHIN REACH PER THE 2020 FBC SEC. R
 2903.9.3.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2021-07-27 Cont ID  
Sent By cthroop Date 2021-07-27 Time 07:58 Rev Time 0.00
Received By cthroop Date 2021-07-24 Time 07:11 Sent To  
Notes
2021-07-27 07:59:20PROVISO ON PLAN PAGE A-3.1
 A SEPERATE ROOFING PERMIT IS REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-12-04 Cont ID  
Sent By cthroop Date 2021-12-04 Time 09:11 Rev Time 0.00
Received By cthroop Date 2021-12-04 Time 08:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-11-19 Cont ID  
Sent By cthroop Date 2021-11-19 Time 08:47 Rev Time 0.00
Received By cthroop Date 2021-11-18 Time 14:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-29 Cont ID  
Sent By medwards Date 2021-06-29 Time 15:22 Rev Time 0.00
Received By medwards Date 2021-06-29 Time 15:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By ajones Date 2021-11-05 Time 14:00 Rev Time 0.00
Received By ajones Date 2021-11-05 Time 14:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-07-06 Cont ID  
Sent By rthermid Date 2021-07-06 Time   Rev Time  
Received By rthermid Date 2021-07-06 Time   Sent To I
Notes
2021-07-06 12:01:55ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 7/6/2021
 ________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-442(2)(A): GENERAL LANDSCAPING STANDARDS FOR
 SINGLE-FAMILY DWELLING UNITS SHALL BE AS FALLOWS:
  
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
  
 2. ADDITIONALLY, A RIGHT-OF-WAY PERMIT WILL NEED TO BE
 ACQUIRED FROM THE CITY?S ENGINEERING DEPARTMENT
 (561.494.1040) FOR ANY CHANGES TO THE DRIVEWAY. PLEASE
 INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE SURFACES
 (EXISTING AND PROPOSED) LOCATED WITHIN THE FRONT YARD
 (FROM FRONT PROPERTY LINE TO THE FRONT BUILDING
 FACADE).
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561-822-1443
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  