| Plan Review Stops For Permit 21060673 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2021-10-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-08 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-08 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2021-10-08 14:01:01 | ABOVE GARAGE HABITABLE SPACE GIVEN THE ADDRESS OF 7113 | | | S FLAGLER DR |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-01 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-01 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2021-09-01 13:30:31 | COMMENTS NOT ADDRESSED. | | | | | | PLEASE HAVE OWNER COORDINATE WITH [email protected] OR | | | CALL 561-805-6659 FOR THE LIVABLE SPACE TO BE GIVEN AN | | | ADDRESS FOR GUEST SUITE ABOVE THE PROPOSED GARAGE. ALL | | | ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER | | | HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY | | | ADDRESS NUMBER. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-06-21 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-06-21 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2021-06-21 17:07:20 | PLEASE HAVE OWNER COORDINATE WITH [email protected] OR | | | CALL 561-805-6659 FOR THE LIVABLE SPACE TO BE GIVEN AN | | | ADDRESS FOR GUEST SUITE ABOVE THE PROPOSED GARAGE. ALL | | | ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER | | | HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY | | | ADDRESS NUMBER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2021-12-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-28 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-28 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-04 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-04 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2021-12-01 09:57:43 | BUILDING REVIEW APPROVED PENDING APPROVAL OF ELEVATION | | | CERTIFICATE | | | AN INTERNAL PEER REVIEW AND APPROVAL OF CONSTRUCTION | | | DRAWING ELEVATION CERTIFICATE IS REQUIRED. CT | | | PROVISO ON PG. A-1-1: FLOOD VENTS ARE NOT REQUIRED FOR | | | THE CABANA. DESIGNER WILL REMOVE VENTS UPON REVISION. | | | REDLINED VENTS. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-09 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-09 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2021-11-09 15:53:51 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | NOTICE: | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE, REVIEWED | | | AND APPROVED, IS REQUIRED PRIOR TO PERMIT. SEE COMMENTS | | | UNDER NFIP REVIEW. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-29 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-29 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2021-10-29 16:06:04 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENT FROM 1ST REVIEW NOT ADDRESSED. SEE #2 BELOW. | | | | | | 2. PROVIDE SOILS REPORT. (NOT ADDRESSED) | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. | | | | | | NOTICE: | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE, REVIEWED | | | AND APPROVED, IS REQUIRED PRIOR TO PERMIT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-04 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-01 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2021-10-04 07:50:16 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | NOTICE: A SEPERATE PERMIT IS REQUIRED FOR FREE STANDING | | | GARAGE. (NOT CORRECTED) | | | NOTICE: A SEPERATE PERMIT IS REQUIRED FOR SITE WALLS. | | | (CORRECTED-PERMIT ISSUED FOR SITE WALLS) | | | | | | 1. PROVIDE AN UPDATED BOUNDRY LINE SURVEY. (NOT | | | ADDRESSED) | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE SOILS REPORT. (NOT ADDRESSED) | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXT. | | | DOORS. (CORRECTED-PRODUCT APPROVALS SHALL BE DEFERRED) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | DEFERRAL OPTION: | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 4. ROOF PLAN PAGE A-3.1 STATES ROOF ASSEMBLY INSULATION | | | R VALUE AS R-30. ENERGY SUBMITTAL STATES ROOF ASSEMBLY | | | R VALUE AS R-20. (CORRECTED) | | | PLEASE CLARIFY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 5. PROVIDE THE ICC-ES REPORT FOR THE PROPOSED ICYNENE | | | SPRAY FOAM INSULATION. (SEE PROVISO ON PLAN PAGE A-3.1) | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-27 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-24 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2021-07-27 08:28:02 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: A SEPERATE PERMIT IS REQUIRED FOR FREE STANDING | | | GARAGE. | | | NOTICE: A SEPERATE PERMIT IS REQUIRED FOR SITE WALLS. | | | | | | 1. PROVIDE AN UPDATED BOUNDRY LINE SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE SOILS REPORT. | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXT. | | | DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | DEFERRAL OPTION: | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 4. ROOF PLAN PAGE A-3.1 STATES ROOF ASSEMBLY INSULATION | | | R VALUE AS R-30. ENERGY SUBMITTAL STATES ROOF ASSEMBLY | | | R VALUE AS R-20. | | | PLEASE CLARIFY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 5. PROVIDE THE ICC-ES REPORT FOR THE PROPOSED ICYNENE | | | SPRAY FOAM INSULATION. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-09-29 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-29 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-07-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-01 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-01 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2021-07-01 17:39:10 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) GARAGE PANEL TO HAVE MAIN BREAKER INSTALLED PER | | | 225.33 | | | | | | 225.33 MAXIMUM NUMBER OF DISCONNECTS. (A) GENERAL. THE | | | DISCONNECTING MEANS FOR EACH SUPPLY PERMITTED BY 225.30 | | | SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR SIX | | | CIRCUIT BREAKERS MOUNTED IN A SINGLE ENCLOSURE, IN A | | | GROUP OF SEPARATE ENCLOSURES, OR IN OR ON A SWITCHBOARD | | | OR SWITCHGEAR. THERE SHALL BE NO MORE THAN SIX | | | DISCONNECTS PER SUPPLY GROUPED IN ANY ONE LOCATION. | | | | | | 2) GARAGE PANEL TO HAVE A GROUNDING ELECTRODE SYSYEM | | | INSTALLED 250.33 | | | | | | 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY A FEEDER(S) | | | OR BRANCH CIRCUIT(S). (A) GROUNDING ELECTRODE. | | | BUILDING(S) OR STRUCTURE(S) SUPPLIED BY FEEDER(S) OR | | | BRANCH CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR | | | GROUNDING ELECTRODE SYSTEM INSTALLED IN ACCORDANCE WITH | | | PART III OF ARTICLE 250. THE GROUNDING ELECTRODE | | | CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE WITH | | | 250.32(B) OR (C). WHERE THERE IS NO EXISTING GROUNDING | | | ELECTRODE, THE GROUNDING ELECTRODE(S) REQUIRED IN | | | 250.50 SHALL BE INSTALLED. | | | | | | 3) FOYER TO HAVE OUTLETS INSTALLED PER 210.52 (I) | | | | | | 210.52(I) FOYERS. FOYERS THAT ARE NOT PART OF A HALLWAY | | | IN ACCORDANCE WITH 210.52(H) AND THAT HAVE AN AREA THAT | | | IS GREATER THAN 5.6 M2 (60 FT2) SHALL HAVE A | | | RECEPTACLE(S) LOCATED IN EACH WALL SPACE 900 MM (3 FT) | | | OR MORE IN WIDTH. DOORWAYS, DOOR-SIDE WINDOWS THAT | | | EXTEND TO THE FLOOR, AND SIMILAR OPENINGS SHALL NOT BE | | | CONSIDERED WALL SPACE. | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-17 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-17 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2021-09-17 08:53:37 | 09/17/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-06 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-06 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2021-07-06 17:06:50 | 07/06/21 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET P3.1; | | | A. THE UNDERGROUND GAS NEED TO HAVE A VENT ON ONE SIDE | | | PER THE 2020 G2415.8.1 CONDUIT WITH ONE END TERMINATING | | | OUTDOORS. | | | | | | B. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION PER THE 2020 FBC RES. SEC. G2421.1. | | | | | | C. THE SYSTEM DOES NOT HAVE THE TOTAL BTU'S; THE FUTURE | | | IS NOT SHOWN; PLEASE LIST THE BTU LOAD OF EACH | | | APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER | | | TO THE 2020 FBC RES. SEC. G2413. LIST THE BTU LOAD OF | | | EACH APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. | | | REFER TO THE 2020 FBC RES. SECS. G2413.3, G2413.4, AND | | | TABLES G2413.4 (1) THROUGH G2413.4 (21). | | | | | | D. SUBMIT MANUFACTURER?S SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT | | | (FUTURE GENERATOR, FIRE PIT, TANK-LESS, AND | | | RANGE/OVEN)TO VERIFY COMPLIANCE WITH 2020 FBC RES. SEC. | | | G2408.1. | | | | | | E. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT | | | SHALL BE ONSITE AT THE INSPECTION TIME PER THE 2020 FBC | | | RES. SEC. G2413.2 AND G2404.3. | | | | | | F. PLEASE SHOW AND LABEL ALL UNIONS IN FRONT OF | | | REGULATOR 1' OF EITHER SIDE PER THE 2020 FBC RES. SEC | | | G2421.2. | | | | | | G. PLEASE SHOW AND LABEL THE SHUTOFF VALVE ON GAS | | | ISOMERIC PER THE 2020 FBC RES. SEC. G2420.5. | | | | | | H. THE SHUT OFF INSIDE SHALL BE ACCESSIBLE WITHOUT | | | MOVING THE EQUIPMENT PER THE 2020 FBC SEC. G2403 (202) | | | GD, ACCESS. | | | | | | I. PLEASE SHOW AND LABEL ALL DRIP LEGS ON EQUIPMENT | | | INSTALLED, EXCEPT FOR APPLIANCES, RANGE, DRYERS & OD | | | GRILLS PER THE 2020 FBC RES. SEC. G2419.2. | | | | | | J. THE LOCATION OF THE WATER HEATER SHALL COMPLY WITH | | | THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1. J. ON THE HOUSE | | | PLAN, SHOW THE LOCATION OF THE TANK-LESS WATER HEATER | | | AND THE LOCATION AND DISTANCE OF ANY OPERABLE DOORS OR | | | WINDOWS IN RELATION TO THE WATER HEATER. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | K. A NOTE MAY BE PLACED ON PLANS. L. PIPES NOT IN | | | CONDITION SPACE NEED TO BE INSULATED WITH A MINIMUM R-3 | | | PER THE 2020 FBC SEC. RE 403.5.3. | | | | | | L. IF TANK-LEES UNITS ARE CONDENSATION, THEY NEED TO BE | | | 1' AWAY FROM STRUCTURE PER THE 2020 FBC SEC. R318.5. A | | | NOTE MAY BE PLACED ON PLANS. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2021-12-29 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-12-28 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-04 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-15 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-09 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-02 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-29 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-14 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-04 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-01 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-27 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-23 |
Time |
06:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-05 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-28 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2022-01-03 13:56:55 | RECEIPT MU-2021-059934 - $6796.18 PAID | | 2021-12-28 17:33:01 | IMPACT FEE QUESTIONNAIRE UPLOADED - EMAILED PBC IMPACT | | | FEE OFFICE. CC |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-27 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-27 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2021-07-27 07:58:05 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-02 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-02 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-29 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-29 |
Time |
15:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
6 |
Status |
P |
Date |
2021-12-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-28 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-28 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2021-12-28 07:39:26 | PEER REVIEW COMPLETE |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
F |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-04 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-04 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2021-11-18 17:09:13 | NFIP REVIEW APPROVED PENDING INTERNAL PEER REVIEW AND | | | APPROVAL OF CONSTRUCTION DRAWING ELEVATION CERTIFICATE. | | | CT | | | PROVISO ON PG. A-4.2: FLOOD VENTS ARE NOT REQUIRED FOR | | | THE CABANA. DESIGNER WILL REMOVE VENTS UPON REVISION. | | | REDLINED VENTS. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-09 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-09 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2021-11-09 16:03:51 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 4TH REVIEW | | | | | | | | | NOTICE: PROVIDE A CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE. | | | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD | | | ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD. | | | MAIN DWELLING UNIT IS LOCATED IN FLOOD ZONE AE 7 . BFE | | | IS 7.0' NAVD. DFE SHALL NOT BE LESS THAN 9.0 FEET NAVD. | | | FREE STANDING CABANA/GARAGE IS LOCATED IN FLOOD ZONE AE | | | 6. BFE IS 6.0' NAVD. DFE SHALL NOT BE LESS THAN 8.0' | | | NAVD. | | | | | | | | | NOTICE: | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | SUBMIT TO BUILDING DEPARTMENT FOR REVIEW. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | | | | NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES | | | ARE REQUIRED FOR THE FREE STANDING CABANA/GARAGE. FLOOD | | | ZONE IS AE 6. BFE IS 6.0' NAVD. DFE SHALL BE NOT LESS | | | THAN 8.0' NAVD. | | | | | | NOTICE: PROVISO ON PLAN PAGE S-1.1. A SEPERATE PERMIT | | | IS REQUIRED FOR FREE STANDING GARAGE. | | | | | | NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC | | | | | | NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC | | | | | | NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER | | | INSPECTION HOLDS REMOVED. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2021-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-29 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-29 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2021-10-29 16:07:55 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 3RD REVIEW | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD | | | ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD. | | | DESIGN FLOOD ELEVATION OF MAIN DWELLING UNIT SHALL NOT | | | BE LESS THAN 9.0 FEET NAVD. FREE STANDING GARAGE, | | | LOCATED IN SFHA W/BFE 6.0' NAVD. | | | | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | SUBMIT TO BUILDING DEPARTMENT FOR REVIEW. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | | | | NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES | | | ARE REQUIRED FOR FREE STANDING GARAGE. BFE 6.0' DFE | | | 9.0' NAVD. | | | | | | NOTICE: PROVISO ON PLAN PAGE S-1.1 | | | | | | NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC | | | | | | NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC | | | | | | NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER | | | INSPECTION HOLDS REMOVED. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-04 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-01 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2021-10-04 08:04:46 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 2ND REVIEW | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD | | | ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD. | | | DESIGN FLOOD ELEVATION OF MAIN DWELLING UNIT SHALL NOT | | | BE LESS THAN 9.0 FEET NAVD. FREE STANDING GARAGE, | | | LOCATED IN SFHA W/BFE 6.0' NAVD. | | | | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | SUBMIT TO BUILDING DEPARTMENT FOR REVIEW. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | | | | NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES | | | ARE REQUIRED FOR FREE STANDING GARAGE. BFE 6.0' DFE | | | 9.0' NAVD. | | | | | | NOTICE: PROVISO ON PLAN PAGE S-1.1 | | | | | | NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC | | | | | | NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC | | | | | | NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER | | | INSPECTION HOLDS REMOVED. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-27 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-24 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2021-07-24 07:17:17 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). IT IS LOCATED IN FLOOD ZONE AE WITH BASE FLOOD | | | ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD. | | | DESIGN FLOOD ELEVATION SHALL BE NOT LESS THAN 9.0 FEET | | | NAVD. | | | | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | SUBMIT TO BUILDING DEPARTMENT FOR REVIEW. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | | | | NOTICE: A SEPERATE PERMIT AND ELEVATION CERTIFICATES | | | ARE REQUIRED FOR FREE STANDING GARAGE. BFE 6.0' DFE | | | 9.0' NAVD. | | | | | | NOTICE: PROVISO ON PLAN PAGE S-1.1 | | | | | | NOTICE: PRINT HOLD FOR CONSTRUCTION DRAWING EC | | | | | | NOTICE: C/O HOLD FOR FINISHED CONSTRUCTION EC | | | | | | NOTICE: COMMENTS TO BE ADDED TO INSPECTION SCREEN AFTER | | | INSPECTION HOLDS REMOVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-17 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-17 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2021-09-17 08:22:21 | 09/17/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-06 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-06 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2021-07-06 16:19:24 | 07/06/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET P1.1 IN THE KITCHEN IT THERE IS A BAR SINK | | | SHOWN AND LABELED BSK. THERE IS NO DRAIN TO, NOT IN | | | USE; PLEASE DELETE OR SHOW ON LAYOUT AND ISOMETRIC PER | | | THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | 2. THE FUTURE CAP OFF SHOWING A WASHING MACHINE WILL | | | REQUIRE THE VALVES TO BE ACCESSIBLE WITHOUT MOVING OF | | | THE UNITS AND WITHIN REACH PER THE 2020 FBC SEC. R | | | 2903.9.3. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-27 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-24 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2021-07-27 07:59:20 | PROVISO ON PLAN PAGE A-3.1 | | | A SEPERATE ROOFING PERMIT IS REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-04 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-04 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-19 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-18 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-29 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-29 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-11-05 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-11-05 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-07-06 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-07-06 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-07-06 12:01:55 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 7/6/2021 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-442(2)(A): GENERAL LANDSCAPING STANDARDS FOR | | | SINGLE-FAMILY DWELLING UNITS SHALL BE AS FALLOWS: | | | | | | A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | | | 2. ADDITIONALLY, A RIGHT-OF-WAY PERMIT WILL NEED TO BE | | | ACQUIRED FROM THE CITY?S ENGINEERING DEPARTMENT | | | (561.494.1040) FOR ANY CHANGES TO THE DRIVEWAY. PLEASE | | | INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE SURFACES | | | (EXISTING AND PROPOSED) LOCATED WITHIN THE FRONT YARD | | | (FROM FRONT PROPERTY LINE TO THE FRONT BUILDING | | | FACADE). | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561-822-1443 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|