Plan Review Details - Permit 21060535
Plan Review Stops For Permit 21060535
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-08-16 Cont ID  
Sent By jgomez Date 2021-08-16 Time 11:04 Rev Time 0.00
Received By jgomez Date 2021-08-16 Time 11:04 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-07-12 Cont ID  
Sent By jwitmer Date 2021-07-12 Time 18:56 Rev Time 0.00
Received By jwitmer Date 2021-07-12 Time 18:45 Sent To  
Notes
2021-07-12 18:56:10TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-08-16 Cont ID  
Sent By jgomez Date 2021-08-16 Time 13:31 Rev Time 0.00
Received By jgomez Date 2021-08-16 Time 09:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-13 Cont ID  
Sent By jgomez Date 2021-07-13 Time 11:14 Rev Time 0.00
Received By jgomez Date 2021-07-13 Time 09:19 Sent To  
Notes
2021-07-13 11:16:44ALTERATION BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21060535
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1- PLANS ARE MISSING THE INFORMATION OF CABINETRY AT
 NEW NURSES STATION, BUSINESS OFFICE, ETC, SHOWING
 COMPLIANCE WITH THE ACCESSIBILITY REQUIREMENTS OF SEC.
 902 FBC-ACCESSIBILITY.
 SEC. 806 FBC-EXISTING BUILDING AND SEC. 902
 FBC-ACCESSIBILITY.
  
 2- TYPICAL WALL SECTION ON SHEET A-1 SHOW FASTENING OF
 THE PARTITION TO THE SUSPENDED CEILING. TYPICALLY, THE
 PARTITIONS ARE BRACED TO THE STRUCTURAL CEILING, NOT
 THE SUSPENDED CEILING IN ORDER TO PROVIDE ADEQUATE
 STIFFNESS AS REQUIRED BY SEC. 1607.14 FBC-BUILDING.
 REVISE DETAIL AS REQUIRED OR PROVIDE CALCULATIONS
 SHOWING THAT SUSPENDED CEILING WILL PROVIDE THE
 REQUIRED STIFFNESS. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 3- WALL LEGEND AND LETTERS KEYED ON THE FLOOR PLAN
 DON'T MATCH. THEY NEED TO BE COORDINATED. CHECK LETTERS
 C AND D AND REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 4- ALL DRAWINGS (COVER SHEET, A-1 AND E-1) NEED
 ARCHITECT'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC.
 481 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
 PLANS WERE SUBMITTED ELECTRONICALLY. NEED PLANS WITH
 ARCHITECT'S DIGITAL SIGNATURE OR PROVIDE HARD COPY
 PLANS WITH THE ORIGINAL SEAL AND SIGNATURE.
 NOTE: COVER SHEET IS MISSING THE ARCHITECT'S TITLE
 BLOCK.
  
  
 ARCHITECTS
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-29 Cont ID  
Sent By jleahy Date 2021-07-29 Time 09:09 Rev Time 0.00
Received By jleahy Date 2021-07-29 Time 09:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-22 Cont ID  
Sent By jleahy Date 2021-06-22 Time 14:16 Rev Time 0.00
Received By jleahy Date 2021-06-22 Time 14:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-07-27 Cont ID  
Sent By pleduc Date 2021-07-27 Time   Rev Time 0.00
Received By pleduc Date 2021-07-27 Time 09:24 Sent To  
Notes
2021-07-27 09:24:38FIRE PROVISO:
  
 FIRE SPRINKLER HEAD PROTECTION MODIFICATION IS
 REQUIRED.
  
 ALL WORK ON THE FS SYSTEM, INCLUDING DEMO, SHALL BE
 DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-06-11 Cont ID  
Sent By pleduc Date 2021-06-11 Time   Rev Time 0.00
Received By pleduc Date 2021-06-11 Time 09:20 Sent To  
Notes
2021-06-11 09:23:38FIRE PROVISO:
  
 FIRE SPRINKLER HEAD PROTECTION MODIFICATION IS
 REQUIRED.
  
 ALL WORK ON THE FS SYSTEM, INCLUDING DEMO, SHALL BE
 DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-08-17 Cont ID  
Sent By jgomez Date 2021-08-17 Time 16:13 Rev Time 0.00
Received By jgomez Date 2021-08-17 Time 16:03 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-16 Cont ID  
Sent By jgomez Date 2021-08-16 Time 15:41 Rev Time 0.00
Received By jgomez Date 2021-07-23 Time 11:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-13 Cont ID  
Sent By jgomez Date 2021-07-13 Time 11:16 Rev Time 0.00
Received By jgomez Date 2021-06-10 Time 09:53 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-08-16 Cont ID  
Sent By jgomez Date 2021-08-16 Time 13:24 Rev Time 0.00
Received By jgomez Date 2021-08-16 Time 13:24 Sent To  
Notes
2021-08-16 13:25:15SINKS REMOVAL.

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-07-13 Cont ID  
Sent By jgomez Date 2021-07-13 Time 09:42 Rev Time 0.00
Received By jgomez Date 2021-07-13 Time 09:29 Sent To  
Notes
2021-07-13 09:43:45SINKS REMOVAL.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2021-08-27 Cont ID  
Sent By rgathrig Date 2021-08-27 Time 15:38 Rev Time 0.00
Received By rgathrig Date 2021-08-27 Time 15:38 Sent To  
Notes
2021-08-27 15:39:42PRIVATE PROVIDER INSPECTIONS ONLY
  
 TEW & TAYLOT APPROVED
  
 RICHARD GATHRIGHT
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-08-17 Cont ID  
Sent By jgomez Date 2021-08-17 Time 16:13 Rev Time 0.00
Received By jgomez Date 2021-08-17 Time 16:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-08-16 Cont ID  
Sent By jgomez Date 2021-08-16 Time 13:26 Rev Time 0.00
Received By jgomez Date 2021-08-16 Time 13:26 Sent To  
Notes
2021-08-16 13:28:44SIGNATURE REVIEW COMMENTS:
  
 ORIGINAL COMMENT:
 1- ALL DRAWINGS (COVER SHEET, A-1 AND E-1) NEED
 ARCHITECT'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC.
 481 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
 PLANS WERE SUBMITTED ELECTRONICALLY. NEED PLANS WITH
 ARCHITECT'S DIGITAL SIGNATURE OR PROVIDE HARD COPY
 PLANS WITH THE ORIGINAL SEAL AND SIGNATURE.
 NOTE: COVER SHEET IS MISSING THE ARCHITECT'S TITLE
 BLOCK.
  
 ARCHITECTS
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 RESPONSE:
 COVER SHEET WAS NOT RESUBMITTED WITH ARCHITECT'S
 DIGITAL SIGNATURE. THIS SHEET NEEDS THE ARCHITECT'S
 DIGITAL SIGNATURE.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-13 Cont ID  
Sent By jgomez Date 2021-07-13 Time 09:45 Rev Time 0.00
Received By jgomez Date 2021-07-13 Time 09:43 Sent To  
Notes
2021-07-13 09:48:17SIGNATURE REVIEW COMMENTS:
  
 1- ALL DRAWINGS (COVER SHEET, A-1 AND E-1) NEED
 ARCHITECT'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC.
 481 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
 PLANS WERE SUBMITTED ELECTRONICALLY. NEED PLANS WITH
 ARCHITECT'S DIGITAL SIGNATURE OR PROVIDE HARD COPY
 PLANS WITH THE ORIGINAL SEAL AND SIGNATURE.
 NOTE: COVER SHEET IS MISSING THE ARCHITECT'S TITLE
 BLOCK.
  
 ARCHITECTS
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]