Plan Review Details - Permit 21060460
Plan Review Stops For Permit 21060460
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-06-08 Cont ID  
Sent By cpuell Date 2021-06-08 Time 09:16 Rev Time 0.00
Received By cpuell Date 2021-06-08 Time 09:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-09-29 Cont ID  
Sent By cthroop Date 2021-09-29 Time 11:08 Rev Time 0.00
Received By cthroop Date 2021-09-28 Time 06:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-28 Cont ID  
Sent By cthroop Date 2021-07-28 Time 07:52 Rev Time 0.00
Received By cthroop Date 2021-07-27 Time 14:29 Sent To  
Notes
2021-07-28 07:58:46PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: VALUE ADJUSTED TO $293,512.00 BASED ON THE ICC
 BUILDING VALUATION DATA.
  
 PROVISO ON PLAN PAGE G0.01: A SEPERATE ROOFING PERMIT
 IS REQUIRED.
  
 1. PROVIDE WINDOW AND DOOR ROUGH OPENING AND DESIGN
 PRESSURES.
 YOU MAY PROVIDE A WINDOW AND/OR DOOR SCHEDULE
 WITH THE FOLLOWING INFORMATION:
  
 1. LOCATION REFERENCE TO OPENING NUMBER ON PLAN.
 2. DEVICE TYPE WINDOW/DOOR/SHUTTER
 3. ROUGH OPENING WXH (AREA SF)
 4. DESIGN PRESSURES TABLE R301.1.(2) OR ASCE 7-16
 5. NOA OR FL NUMBER
 6. MAX DESIGN PRESSURE FROM NOA OR FL
 7. IDENTIFY EGRESS OPENINGS
  
 2. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXT.
 DOORS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 3. PROVIDE A SITE PLAN W/BOUNDRY LINE SURVEY
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDARY LINE SURVEY.
  
 4. PROVIDE A SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH
 FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 5. PROVIDE FINISHED FLOOR ELEVATION.
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-13 Cont ID  
Sent By jleahy Date 2021-07-13 Time 16:24 Rev Time 0.00
Received By jleahy Date 2021-07-13 Time 16:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-05 Cont ID  
Sent By jleahy Date 2021-10-05 Time 14:54 Rev Time 0.00
Received By jleahy Date 2021-10-05 Time 13:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-29 Cont ID  
Sent By cthroop Date 2021-09-29 Time 11:08 Rev Time 0.00
Received By cthroop Date 2021-08-23 Time 07:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-28 Cont ID  
Sent By cthroop Date 2021-07-28 Time 07:58 Rev Time 0.00
Received By cthroop Date 2021-06-30 Time 12:25 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-10-27 Cont ID  
Sent By lmarchan Date 2021-10-27 Time 10:40 Rev Time 0.00
Received By lmarchan Date 2021-10-05 Time 10:46 Sent To  
Notes
2021-10-26 15:08:57RECEIPT MU-2021-048501 - $11,623.07 PAID
2021-10-05 10:46:4710/5/21 EMAILED IMPACT FOR REVIEW-AO
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-07-28 Cont ID  
Sent By cthroop Date 2021-07-28 Time 07:49 Rev Time 0.00
Received By cthroop Date 2021-07-28 Time 07:49 Sent To  
Notes
2021-07-28 07:49:57PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-07-12 Cont ID  
Sent By medwards Date 2021-07-12 Time 16:17 Rev Time 0.00
Received By medwards Date 2021-07-12 Time 16:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-09 Cont ID  
Sent By lcrespo Date 2021-09-09 Time 17:43 Rev Time 0.00
Received By lcrespo Date 2021-09-09 Time 17:35 Sent To  
Notes
2021-09-09 17:43:1809/09/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-07-14 Cont ID  
Sent By abelisle Date 2021-07-14 Time 15:58 Rev Time 0.00
Received By abelisle Date 2021-07-14 Time 15:48 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2021-07-28 Cont ID  
Sent By cthroop Date 2021-07-28 Time 07:50 Rev Time 0.00
Received By cthroop Date 2021-07-27 Time 14:29 Sent To  
Notes
2021-07-28 07:50:48PROVISO ON PLAN PAGE GO.O1: SEPERATE ROOFING PERMIT
 REQUIRED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-10-05 Cont ID  
Sent By jleahy Date 2021-10-05 Time 14:54 Rev Time 0.00
Received By jleahy Date 2021-10-05 Time 14:54 Sent To  
Notes
2021-10-05 14:56:55PLANS SENT TO STORAGE JLEAHY
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-09-29 Cont ID  
Sent By cthroop Date 2021-09-29 Time 09:53 Rev Time 0.00
Received By cthroop Date 2021-09-29 Time 09:53 Sent To  
Notes
2021-09-29 09:55:08SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 2ND REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PLUMBING AND MECHANICLA PLANS.
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-12 Cont ID  
Sent By medwards Date 2021-07-12 Time 16:22 Rev Time 0.00
Received By medwards Date 2021-07-12 Time 16:22 Sent To  
Notes
2021-07-12 16:24:46THE PLUMBING AND ELECTRICAL DRAWINGS MUST BE DIGITALLY
 SIGNED BY AN ENGINEER OR THE LICENSED TRADE CONTRACTOR
 THAT HOLDS THE PERMIT TO INSTALL THE WORK CAN PRINT AND
 SIGN THEIR NAME ON EACH SHEET OF DRAWINGS THAT IS SHOWN
 FOR THEIR TRADE.
  
 FS 471.003(H)
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-08-26 Cont ID  
Sent By ajones Date 2021-08-26 Time 13:11 Rev Time 0.00
Received By ajones Date 2021-08-26 Time 13:08 Sent To  
Notes
2021-08-26 13:11:018/26/21- PASS WITH THE PROVISOS
 1, SEPERATE PERMIT REQUIRED FOR LANDSCAPING, DRIVEWAY
 AND ANY FENCE PROPOSED.
  
 ANGELLA VANN
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2021-07-21 Cont ID  
Sent By AV Date 2021-07-21 Time 14:23 Rev Time 0.00
Received By ajones Date 2021-07-21 Time 14:23 Sent To  
Notes
2021-07-21 14:25:387/21/21- FAILED. PLEASE PROVIDE THE SURVEY SHOWING THE
 BUILDING SETBACKS FROM THE PROPERTY LINE.
  
 ANGELLA VANN
 561-822-1441
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved