| Plan Review Stops For Permit 21060411 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-08-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-08-11 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-08-11 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2021-08-11 17:00:59 | PRIMARY FRONT HOUSE TO HAVE THE ADDRESS OF 201 DYER RD | | | REAR GUEST HOUSE GIVEN ADDRESS OF 203 DYER RD (PERMIT | | | 21071206) |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-06-10 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-06-10 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2021-06-10 16:22:16 | PLEASE COORDINATE WITH [email protected] FOR THE LIVABLE | | | SPACE TO BE GIVEN AN ADDRESS FOR GUEST SUITE. ALL | | | ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER | | | HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY | | | ADDRESS NUMBER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-17 |
Time |
06:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-17 |
Time |
06:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-15 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-15 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2021-09-15 15:52:21 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 6TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE NOTE PLACED ON THE GARAGE FLOOR "MIN. 8'-0" | | | NAVD" DOES NOT RESOLVE THE CONFLICT WITH THE T.O. SLAB | | | NOTES. THE LOWEST POINT OF THE GARAGE FLOOR HAS TO BE | | | NO MORE THAN -6" OR FLOOD VENTS WILL BE REQUIRED. | | | CORRECT PAGE S-1 AND RE-SUBMIT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2021-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-10 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-10 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2021-09-14 09:17:11 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 5TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. BASED ON REVIEW OF THE UNDER CONSTRUCTION ELEVATION | | | CERTIFICATE, THE GARAGE FLOOR LOWEST ELEVATION MUST BE | | | AT OR ABOVE THE DESIGN FLOOD ELEVATION OF 8.0 FT NAVD. | | | REVISE FOUNDATION PLAN PAGE S-1.0 AND RE-SUBMIT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-10 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-10 |
Time |
05:58 |
Sent To |
|
|
| Notes |
| 2021-09-10 08:17:58 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: SEE PLAN PAGE SK-1 FOR THE FOLLOWING: | | | | | | 1. VERTICAL DATUM ON PG SK-1 IS IN NGVD. | | | CORRECT TO NAVD AND RE-SUBMIT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-01 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-01 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2021-09-01 17:31:11 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/RPX306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | REF: REVIEW 3RD NFIP REVIEW COMMENTS FOR THE FOLLOWING. | | | | | | 1. BASED ON THE VERTICAL DATUM USED ON THE PLANS WITH A | | | CONVERSION FACTOR OF 1.519 PROVIDED (TO CONVERT FROM | | | NGVD TO NAVD), EITHER THE GAGARE FLOOR HAS TO BE RAISED | | | OR FLOOD VENTS WILL BE REQUIRED. (REVISION REQUIRED). | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-25 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-21 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-10 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-08 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2021-07-10 07:30:58 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | : | | | | | | NOTICES: | | | 1. SEPERATE PERMITS REQUIRED FOR CABANA AND COVERED | | | TERRACE. | | | 2. 2-STORY SFR ENCROACHES INTO A SPECIAL FLOOD HAZARD | | | AREA (SFHA). FLOOD ZONE AE WITH A BASE FLOOD ELEVATION | | | (BFE) OF 6.0' NAVD. MINIMUM DESIGN FLOOD ELEVATION | | | (DFE) SHALL BE 8.0' NAVD. SEE NFIP REVIEW. | | | 3. PROVISO'S ON PLAN PAGE A0.1 FOR SEPERATE ROOFING AND | | | GENERATOR PERMITS. | | | | | | COMMENTS: | | | | | | 1. REF. GEOTECHNICAL REPORT FROM GFA AND SOILS REPORT | | | FROM ALTERRA FOR THE FOLLOWING: | | | THE GFA REPORT, DATED 2018 IS FOR 211 DYER RD AND DOES | | | NOT INCLUDE INFORMATION FOR THE CABANA AND COVERED | | | TERRACE. PLEASE REMOVE THIS REPORT FROM THIS SUBMITTAL' | | | THE ALTERRA REPORT IS FOR THIS PROJECT AND DOES INCLUDE | | | INFORMATION FOR THE CABANA AND COVERED TERRACE. | | | | | | 2. N/A | | | | | | 3. N/A | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND | | | EXTERIOR DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | DEFERRAL OPTION: | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-25 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-25 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-10 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-10 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-11 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-11 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2021-06-11 15:01:10 | VOICE, DATA AND TV JLEAHY |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-25 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-25 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2021-08-25 10:22:20 | 08/25/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-15 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-15 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-06-28 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-06-28 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-17 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-17 |
Time |
06:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-15 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-15 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-14 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-09 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-02 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-08-30 |
Time |
07:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-26 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2021-08-26 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-08-17 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-10 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-09 |
Time |
06:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-10 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-08-30 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2021-09-02 11:47:04 | RECEIPT MU-2021-042660 - $16,764.79 PAID | | 2021-08-30 07:49:39 | 8/30/21 EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-09 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-09 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2021-07-09 16:37:40 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-21 |
Time |
05:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-21 |
Time |
05:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-06-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-14 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-14 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
P |
Date |
2021-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-14 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-10 |
Time |
05:57 |
Sent To |
|
|
| Notes |
| 2021-09-15 05:43:11 | REMOVE PRINT HOLD. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-01 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-01 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2021-09-01 16:14:54 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 3RD REVIEW CONSTRUCTION DRAWING ELEVATION CERTIFICATE | | | | | | NOTICE: | | | | | | THE 2-STORY SFR ENCROACHES INTO A SPECIAL FLOOD HAZARD | | | AREA (SFHA). FLOOD ZONE AE WITH A BASE FLOOD ELEVATION | | | (BFE) OF 6.0 FEET NAVD. THE DESIGN FLOOD ELEVATION | | | (DFE) SHALL BE NOT LESS THAN 8.0 FEET NAVD. | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED FOR THE | | | 2-STORY SFR | | | | | | THE CABANA AND TERRACE ARE NOT LOCATED IN A SFHA AND DO | | | NOT REQUIRE EC'S. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ELEVATIONS ON PLANS ARE IN NGVD. ELEVATIONS IN | | | ELEVATION CERTIFICATE ARE IN NAVD 88. A CONVERSION | | | FACTOR OF 1.519 HAS BEEN PROVIDED. | | | THIS CONVERSION OF VERTICAL DATUM FROM NGVD TO NAVD | | | WILL PLACE THE GARAGE FLOOR BELOW THE DESIGN FLOOD | | | ELEVATION OF 8.0 FT NAVD (9.5 FT NGVD MINUS 1.519 = | | | 7.981 NAVD). | | | THIS WILL REQUIRE THE ELEVATION OF THE GARAGE FLOOR OR | | | THE INSTALLATION OF FLOOD OPENINGS FOR THE GARAGE. | | | | | | OPTIONS: 1) CHANGE THE VERTICAL DATUM ON PLANS TO | | | NAVD88. THIS IS RECOMMENDED. | | | 2) RAISE THE GARAGE FLOOR .019 FT TO 9.519 NGVD | | | 3) ENTER CORRECT VALUES IN SECTION A9 (B), (C) AND (D). | | | INSTALL REQUIRED FLOOD OPENING IN GARAGE. | | | | | | 2. BASED ON THE CONVERSION FACTOR, ELEVATION OF C2(A) | | | TOP OF BOTTOM FLOOR, SHOULD BE 8.481 NAVD AND C2(B) | | | SHOULD BE 19.781NAVD. C2 (E THRU F) ARE PROPOSED AT | | | THIS TIME BUT MAY NEED ADJUSTING. | | | | | | NOTICE: | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. SUBMIT THIS EC | | | PRIOR TO COMMENCING WORK. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-25 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-21 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2021-08-25 13:43:06 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | | | | NOTICE: | | | | | | THE 2-STORY SFR ENCROACHES INTO A SPECIAL FLOOD HAZARD | | | AREA (SFHA). FLOOD ZONE AE WITH A BASE FLOOD ELEVATION | | | (BFE) OF 6.0 FEET NAVD. THE DESIGN FLOOD ELEVATION | | | (DFE) SHALL BE NOT LESS THAN 8.0 FEET NAVD. | | | | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED FOR THE | | | 2-STORY SFR | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | 1ST REVIEW OF CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. FEMA FORM 086-0-33 (7/15) IS OUT OF DATE. SUBMIT | | | ELEVATION CERTIFICATES ON FEMA FORM 086-0-33 (12/19) | | | WITH AN EXPIRATION DATE OF NOVEMBER 30, 2022. | | | | | | 2. ELEVATIONS ON PLANS ARE IN NGVD. ELEVATIONS ON EC | | | ARE IN NAVD PER SECTION C2 IF THIS IS CORRECT, PROVIDE | | | A CONVERSION FACTOR IN SECTION D - COMMENTS. | | | | | | 3. SECTION B8 SHOULD ONLY CONTAIN FLOOD ZONES WITH BASE | | | FLOOD ELEVATION DATUM. X-500 IS NOT A SPECIAL FLOOD | | | HAZARD AREA AND HAS NO BASE FLOOD ELEVATION | | | REQUIREMENTS. ENTER ONLY AE IN SECTION B8. | | | | | | 4. INCLUDE THE ELEVATION OF THE PROPOSED GENERATOR IN | | | SECTION D - COMMENTS. (SEE SITE PLAN) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2021-07-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-10 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-09 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2021-07-10 07:41:51 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | | | | THE 2-STORY SFR ENCROACHES INTO A SPECIAL FLOOD HAZARD | | | AREA (SFHA). FLOOD ZONE AE WITH A BASE FLOOD ELEVATION | | | (BFE) OF 6.0 FEET NAVD. THE DESIGN FLOOD ELEVATION | | | (DFE) SHALL BE NOT LESS THAN 8.0 FEET NAVD. | | | CABANA AND TERRACE ARE NOT LOCATED IN A SFHA. NO ECC | | | REQUIRED. | | | | | | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED FOR THE | | | 2-STORY SFR | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-25 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-25 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2021-08-25 10:21:44 | 08/25/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-15 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-15 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-15 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-15 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2021-09-15 15:48:43 | PROVISO ON PLAN PAGE A 0.1: SEPERATE ROOFING PERMIT | | | REQUIRED. CT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-07-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-09 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-08 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2021-07-09 16:52:32 | SEPERATE ROOFING PERMIT REQUIRED. PROVISO ON PLAN PAGE | | | A 0.1. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-17 |
Time |
06:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-17 |
Time |
06:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-15 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-15 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-10 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-10 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-21 |
Time |
05:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-21 |
Time |
05:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-14 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-14 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2021-06-14 16:37:46 | THE ENGINEER OF THE MEP SHEETS MUST DIGITALLY SIGN THE | | | DRAWINGS OR YOU CAN BRING ORIGINAL SIGNED AND SEALED | | | PAPER DRAWINGS TO OUR OFFICE. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-09-15 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-09-15 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-09-10 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-09-10 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2021-09-10 10:01:48 | DRIVEWAY TOO WIDE, 20' MAX WIDTH ALL DRIVE OPENINGS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-08-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-08-26 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-08-26 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-06-28 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-06-28 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2021-06-28 14:53:35 | DRIVEWAY TOO WIDE, NEED SEPERATE LANDSCAPE PERMIT. |
|
|