Plan Review Details - Permit 21060362
Plan Review Stops For Permit 21060362
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-08-23 Cont ID  
Sent By jwitmer Date 2021-08-23 Time 15:01 Rev Time 0.00
Received By jwitmer Date 2021-08-23 Time 13:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-07-21 Cont ID  
Sent By jwitmer Date 2021-07-21 Time 11:20 Rev Time 0.00
Received By jwitmer Date 2021-07-21 Time 10:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-21 Cont ID  
Sent By jleahy Date 2021-07-21 Time 17:09 Rev Time 0.00
Received By jleahy Date 2021-07-21 Time 12:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-07-21 Cont ID  
Sent By pleduc Date 2021-07-21 Time   Rev Time 0.00
Received By pleduc Date 2021-07-21 Time 09:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-09-08 Time   Rev Time 0.00
Received By ccarvaja Date 2021-08-18 Time 17:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-07-21 Time   Rev Time 0.00
Received By ccarvaja Date 2021-07-20 Time 17:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-08-30 Cont ID  
Sent By medwards Date 2021-08-30 Time 08:29 Rev Time 0.00
Received By medwards Date 2021-08-30 Time 08:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-07-21 Cont ID  
Sent By medwards Date 2021-07-21 Time 11:18 Rev Time 0.00
Received By medwards Date 2021-07-21 Time 11:04 Sent To  
Notes
2021-07-21 11:29:13THE NOTES AND VENTILATION CALCULATIONS FROM THE
 APPROVED PLANS ARE MISSING FROM THE REVISED PLANS.
 PLEASE PROVIDE THESE ON THE NEW REVISED DRAWINGS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-08 Cont ID  
Sent By ccole Date 2021-09-08 Time 16:32 Rev Time 0.00
Received By ccole Date 2021-09-08 Time 15:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-21 Cont ID  
Sent By ccole Date 2021-07-21 Time 17:52 Rev Time 0.00
Received By ccole Date 2021-07-21 Time 12:01 Sent To  
Notes
2021-07-21 17:52:381ST REVIEW FBC-2020 PLUMBING
 PERMIT REVISION- 21060362
 PERMIT- 19061087
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 6TH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE 6TH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 6TH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE 6TH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
 NEW REVISED RESTROOM AND PLUMBING PLANS FOR THE
 OCCUPANCY HAVE BEEN SUBMITTED BY A NEW DESIGN
 PROFESSIONAL. PLEASE REVIEW THE COMMENTS BELOW AND
 RESUBMIT CORRECTED PLANS.
  
 1) SHEET P-1: PLEASE PROVIDE PLUMBING FIXTURE
 CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC P.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED NUMBER OF PLUMBING FIXTURES.
  
 2) P-1: CORRECT THE RISER DRAWINGS SO THEY MATCH WITH
 THE FLOOR PLAN DRAWINGS- SECTION 107.2.1 WPB- SANITARY
 RISER: A) SHOW THE DRAINS AND VENTS FOR THE NEW
 RESTROOM CLOSEST TO THE STREET ENTRANCE, AND THE HI-LO
 DRINKING FOUNTAIN. B) SHOW THE INDIVIDUAL FIXTURE DRAIN
 POINTS OF CONNECTION TO THE 3-INCH BRANCH. THE PLAN
 CURRENT DRAWING SHOWS ALL POINTS AT THE SAME LOCATION
 WHICH IS NOT CONSISTENT WITH THE FLOOR PLAN. C) THE
 RISER SHOWS THE BRANCH CONNECTING TO AN EXISTING 6-INCH
 SANITARY, THE PLAN SHOWS A 4-INCH SANITARY. WATER
 RISER: A) IDENTIFY ALL FIXTURES. TWELVE FIXTURES
 INCLUDING A HI-LO DINKING FOUNTAIN ARE SHOWN ON THE
 FLOOR PLAN HOWEVER THE RISER INDICATES HOT AND COLD
 WATER LINE CONNECTIONS TO 6 FIXTURES. B) CORRECT THE
 NOTE INDICATING A HW CONNECTION TO A COLD WATER LINE.
 SHOW THE SOURCE OF THE HW SUPPLY TO THE FIXTURES-
 SECTION 607.1 FBC P.
  
 3) P1: PLEASE DEFINE C/U AT HOT WATER PIPE LOCATIONS-
 SECTION 107.21 WPB.
  
 4) P1: AS NOTED ABOVE, THE PLAN DOES NOT CLEARLY SHOW
 HOW HOT OR TEMPERED WATER IS BEING PROVIDED TO THE
 FIXTURES. THERE ARE EWH NOTES AT THE LAVATORY IN THE
 RESTROOM CLOSEST TO THE STREET ENTRANCE, AND AT THE
 DRINKING FOUNTAIN. CLARIFY IF THESE ARE THE LOCATIONS
 AND SOURCES OF WATER HOT OR TEMPERED WATER SUPPLY TO
 ALL THE FIXTURES- SECTION 607.1 FBC P. PLEASE NOTE THAT
 HOT WATER SHALL BE PROVIDED TO THE MOP SINK AND
 TEMPERED WATER SHALL BE PROVIDED TO THE LAVATORIES-
 SECTIONS 416.5 & 607.1.2 FBC P. REVISE THE PLANS TO
 SHOW COMPLIANCE AND PROVIDE EQUIPMENT SCHEDULES ON THE
 PLAN FOR THE WATER HEATERS- 502.1 FBC P.
  
 5) P1: THE DRAWING APPEARS TO INDICATE THE CW PIPING AT
 THE RESTROOMS IS RUNNING THROUGH THE EXTERIOR WALL AND
 THE HW PIPING IS RUNNING ALONG THE EXTERIOR OF THE
 BUILDING. PLEASE SHOW THE ACTUAL PIPING RUN LOCATIONS
 INSIDE THE BUILDING- SECTION 107.2.1 WPB.
  
 6) P1: PLEASE IDENTIFY THE RESTROOMS AS EITHER MALE,
 FEMALE, OR UNISEX- SECTION 403.2 FBC P.
  
 7) P1: DRINKING FOUNTAINS- REFER TO SECTIONS 306, 307,
 AND 602 FBC ACC AND PROVIDE DRINKING FOUNTAIN
 INSTALLATION DETAILS AND ELEVATION VIEWS SHOWING KNEE
 AND TOE CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS.
 SHOW THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A
 FORWARD WHEELCHAIR APPROACH TO THE FOUNTAIN- SECTION
 602.2 FBC ACC, AND SHOW HOW THE LOCATIONS OF THE
 FOUNTAINS WILL BE IN COMPLIANCE WITH SECTION 307.2
 PROTRUSION LIMITS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-30 Cont ID  
Sent By medwards Date 2021-08-30 Time 08:31 Rev Time 0.00
Received By medwards Date 2021-08-30 Time 08:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-07-21 Cont ID  
Sent By medwards Date 2021-07-21 Time 11:30 Rev Time 0.00
Received By medwards Date 2021-07-21 Time 11:30 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved