| Plan Review Stops For Permit 21060282 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-26 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-26 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2021-07-26 11:57:49 | PRIMARY ADDRESS OK FOR SHED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-24 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-24 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-23 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2021-11-23 12:57:50 | METAL BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 4TH REVIEW | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) COPIES OF THE PRODUCT | | | APPROVALS FOR THE ROOF PANELS, WALL PANELS, DOORS AND | | | WINDOWS LISTED ON THE DRAWINGS. FBC WPB 107.1 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-14 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-14 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2021-10-14 15:22:45 | METAL BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 3RD REVIEW | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE COMPLETE COPIES OF THE PRODUCT | | | APPROVALS LISTED ON THE DRAWINGS. FBC WPB 107.1 | | | 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE DOORS - THE DOOR PRODUCT | | | APPROVALS ARE NOT LISTED ON THE DRAWINGS AND WILL NEED | | | TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | | DESIGNER OF RECORD. FBC WPB 107.3.4 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-22 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-22 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2021-07-22 14:19:15 | METAL BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE COMPLETE COPIES OF THE PRODUCT | | | APPROVALS LISTED ON THE DRAWINGS. FBC WPB 107.1 | | | 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE DOORS - THE DOOR PRODUCT | | | APPROVALS ARE NOT LISTED ON THE DRAWINGS AND WILL NEED | | | TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | | DESIGNER OF RECORD. FBC WPB 107.3.4 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-08 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-08 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-07-08 12:48:06 | METAL BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE A SURVEY SHOWING THE LOCATION OF THE | | | METAL BUILDING - SHOW SETBACKS FROM THE PROPERTY LINES | | | AND EXISTING BUILDINGS. FBC WPB 107.2.5 | | | 2) PLEASE SHOW THE INTENDED USE FOR THE BUILDING. FBC | | | CHAPTER 3 | | | 3) PLEASE PROVIDE COMPLETE COPIES OF THE PRODUCT | | | APPROVALS LISTED ON THE DRAWINGS. FBC WPB 107.1 | | | 4) WIND DESIGN DATA SHOWN ON DRAWING SHEET 1 OF 3 SHOWS | | | WIND DESIGNED AS AN "ENCLOSED" BUILDING YET THERE ARE | | | OPENINGS WITH NO COMPONENTS - PLEASE REEVALUATE THE | | | WIND DESIGN DATA. FBC 1609 | | | 5) PLEASE SHOW THE CODE VERSION USED FOR THE DESIGN ON | | | THE DRAWINGS - SHOULD BE (2020 FBC) | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-11-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-11-29 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-11-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-11-10 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2021-11-10 14:20:25 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE PROPOSED STRUCTURE IS CLASSIFIED AS A STORAGE | | | OCCUPANCY PER THE NFPA 101 LIFE SAFETY CODE. | | | | | | THERE ARE 3 DOORS THAT MAY SERVE AND FUNCTION AS THE | | | REQUIRED EXIT. | | | | | | PER NFPA 101 CH 42 STORAGE OCCUPANCIES | | | | | | 42.1.1.5 STORAGE OCCUPANCIES SHALL INCLUDE ALL | | | BUILDINGS OR STRUCTURES | | | USED PRIMARILY FOR THE STORAGE OR SHELTERING OF GOODS, | | | MERCHANDISE, | | | PRODUCTS, OR VEHICLES. | | | | | | 42.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS | | | SHALL HAVE | | | SIGNS IN ACCORDANCE WITH SECTION 7.10. | | | | | | 7.10.1.2 EXITS. | | | 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS | | | THAT OBVIOUSLY | | | AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED | | | BY AN APPROVED | | | SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT | | | ACCESS. | | | | | | PLEASE INDICATE WHICH DOOR IS THE REQUIRED EXIT AND | | | MARK IT ACCORDINGLY WITH AN EXIT SIGN. | | | | | | | | | 2) THE LOCKS ON THE REQUIRED EXIT DOOR SHALL COMPLY | | | WITH NFPA 101 | | | | | | 42.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE | | | PERMITTED. | | | | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE | | | EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. | | | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, | | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | | EGRESS SIDE. | | | | | | PLEASE PROVIDE THE REQUIRED EXIT DOOR WITH A COMPLIANT | | | LOCK IF INSTALLED. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-18 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2021-10-18 14:32:59 | THE PREVIOUS COMMENTS FROM FIRE HAVE NOT BEEN | | | SPECIFICALLY ADDRESSED. | | | | | | | | | PLEASE PROVIDE A DETAILED RESPONSE | | | | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATION OF WHAT THE INTENDED USE OF | | | THE PROPOSED SHED. | | | | | | PLEASE PROVIDE A DETAILED NARRATIVE OF THE INTENDED | | | USE. | | | | | | | | | | | | 2) THERE ARE NO INDICATIONS OF AN INTERIOR FLOOR PLAN. | | | | | | PLEASE PROVIDE A DETAILED INTERIOR FLOOR PLAN. | | | | | | | | | 3) THERE NO INDICATIONS OF ELECTRICAL WIRING OR | | | LIGHTING INCLUDING EXIT SIGNS AND EMERGENCY | | | LIGHTS(BASED OF THE OCCUPANCY) | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-27 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2021-09-27 12:53:35 | THE PREVIOUS COMMENTS FROM FIRE HAVE NOT BEEN | | | SPECIFICALLY ADDRESSED. | | | | | | | | | PLEASE PROVIDE A DETAILED RESPONSE | | | | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATION OF WHAT THE INTENDED USE OF | | | THE PROPOSED SHED. | | | | | | PLEASE PROVIDE A DETAILED NARRATIVE OF THE INTENDED | | | USE. | | | | | | | | | | | | 2) THERE ARE NO INDICATIONS OF AN INTERIOR FLOOR PLAN. | | | | | | PLEASE PROVIDE A DETAILED INTERIOR FLOOR PLAN. | | | | | | | | | 3) THERE NO INDICATIONS OF ELECTRICAL WIRING OR | | | LIGHTING INCLUDING EXIT SIGNS AND EMERGENCY | | | LIGHTS(BASED OF THE OCCUPANCY) | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-26 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2021-07-26 12:15:28 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATION OF WHAT THE INTENDED USE OF | | | THE PROPOSED SHED. | | | | | | PLEASE PROVIDE A DETAILED NARRATIVE OF THE INTENDED | | | USE. | | | | | | | | | | | | 2) THERE ARE NO INDICATIONS OF AN INTERIOR FLOOR PLAN. | | | | | | PLEASE PROVIDE A DETAILED INTERIOR FLOOR PLAN. | | | | | | | | | 3) THERE NO INDICATIONS OF ELECTRICAL WIRING OR | | | LIGHTING INCLUDING EXIT SIGNS AND EMERGENCY | | | LIGHTS(BASED OF THE OCCUPANCY) | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-29 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-24 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-04 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-19 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-24 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-27 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-12 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-08 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-07 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-24 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-24 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-23 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-14 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-14 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-22 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-22 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2021-07-22 14:52:41 | SIGNATURE REVIEW | | | DRAWING LABELED (PRODUCT APPROVAL-SHED.PDF ) DOES NOT | | | SHOW AS ELECTRONICALLY SIGNED IN ADOBE READER - SIGNED | | | AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR - | | | IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-07-08 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-08 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2021-07-08 12:57:24 | SIGNATURE REVIEW | | | DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE | | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR | | | - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-07-26 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-06-22 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-06-22 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-06-22 09:23:07 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 6/22/2021 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PROVIDE A MARKED SURVEY SHOWING THE LOCATION AND | | | SETBACKS OF THE PROPOSED SHED. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561-822-1443 | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG | | | |
|
|