Plan Review Details - Permit 21060273
| Plan Review Stops For Permit 21060273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-15 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-15 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2021-06-15 11:46:39 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | | FL2533-R25 IS INCOMPLETE, PROVIDE THE FOLLOWING | | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO | | | INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN | | | BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE | | | BOTTOM OF THE COVER PAGE. PRINT PAGES 1-4 ONLY. | | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R25 SELECTED SYSTEM NO. W-76 DO NOT | | | MEET THE EXPOSURE CATEGORY C; ZONE 2 MINIMUM DESIGN | | | PRESSURE REQUIREMENT OF -79.38 OR ZONE 3 MINIMUM DESIGN | | | PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM | | | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE | | | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR | | | ZONES 2 & 3 AS PER LIMITATIONS: 5.7.2. ALL APPLICABLE | | | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON | | | THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS | | | NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-09 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-09 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2021-06-09 10:47:28 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | | APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE | | | USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | | 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | | ROOF HEIGHT. | | | 3. WPB A 109.3 BUILDING PERMIT VALUATIONS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS. | | | VALUE TO INCLUDE LABOR AND MATERIALS, ARCHITECTURAL AND | | | DESIGN FEES, OVERHEAD AND PROFIT. ATTACH SIGNED | | | CONTRACT. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-06-10 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-06-10 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-15 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-11 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-06-10 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-08 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-15 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-15 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2021-06-15 11:47:23 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-09 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-09 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2021-06-09 11:04:32 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |