| Plan Review Stops For Permit 21060227 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-06-25 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-06-25 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2021-06-25 14:21:52 | HABITABLE SPACE ABOVE GARAGE GIVEN ADDRESS OF 221 | | | PERSHING WAY |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-06-21 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-06-21 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2021-06-21 16:23:06 | PROPOSED THE ADDRESS OF 221 PERSHING WAY TO THE OWNER | | | FOR THE GUEST SUITE, WAITING TO HERE BACK FROM THEM. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-06-10 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-06-10 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2021-06-10 16:32:42 | PLEASE COORDINATE WITH [email protected] FOR THE LIVABLE | | | SPACE TO BE GIVEN AN ADDRESS FOR GUEST SUITE . ALL | | | ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER | | | HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY | | | ADDRESS NUMBER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-27 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-27 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2022-06-27 15:53:58 | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION/INSPECTIONS TO AVOID CONFLICTS/DELAYS): | | | | | | 1- PROVIDE COMPLETE FRAMING DETAILS/SPECS FOR ELEVATOR | | | SHAFT. SPECIFY ALL FRAMING MEMBERS/CONNECTORS, | | | INCLUDING BRACING TO SUPPORT THE ELEVATOR. | | | 2- PROVIDE COMPLETE DETAILS/SPECS FOR BALCONIES CLAY | | | TILE RAILING. SPECIFY ALL FRAMING MEMBERS/CONNECTORS | | | AND CLAY TILE INSTALLATION. | | | 3- PROVIDE COMPLETE DETAILS/SPECS FOR CANOPIES. SPECIFY | | | ALL FRAMING MEMBERS/CONNECTORS. | | | 4- PROVIDE COMPLETE FRAMING DETAILS/SPECS FOR TRELLIS | | | PERGOLA. SPECIFY ALL FRAMING MEMBERS/CONNECTORS. | | | 5- DESIGNER OF RECORD TO DEPICT THE BUILDING THERMAL | | | ENVELOPE. SPECIFY INSULATION R-VALUES. SEC. R103.2 | | | FBC-ENERGY CONSERVATION. | | | 6- REVISE ENERGY CALCULATIONS MAIN HOUSE. | | | A)PROVIDE INFORMATION: OWNER, BUILDER, PERMIT OFFICE & | | | JURISDICTION (JURISDICTION 604700).SEC. R101.5.1.1.2 | | | FBC- ENERGY CONSERVATION. | | | B)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH | | | PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | C)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | 7- REVISE ENERGY CALCULATIONS GUEST HOUSE. | | | A)PROVIDE INFORMATION: OWNER, BUILDER, PERMIT OFFICE & | | | JURISDICTION (JURISDICTION 604700).SEC. R101.5.1.1.2 | | | FBC- ENERGY CONSERVATION. B)REVISE FLOOR TYPES | | | INFORMATION. THE RAISED FLOOR IS THE GUEST SUITE. | | | REVISE AS REQUIRED. FLOOR AREAS ABOVE UNCONDITIONED | | | SPACE NEED TO HAVE INSULATION. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | C)REVISE SPACES INFORMATION. THERE IS NOT KITCHEN IN | | | THE GUEST SUITE. | | | D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | 8- REVISE LOT DRAINAGE PLAN: DETAIL SECTIONS A-A, B-B | | | AND C-C SHOW WATER RUNNING TO THE NEIGHBOR'S PROPERTY. | | | ALSO, PROVIDE INFORMATION SHOWING DRAINAGE ON THE EAST | | | SIDE OF POOL DECK. | | | 9- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | 10- PROVIDE PRODUCT APPROVAL FOR: A)ALL EXTERIOR DOORS. | | | B)WINDOWS. C)WINDOW MULLIONS (NOTE: SPECIFY MULLION | | | SIZE) D)ROOF CLAY TILE. E)CLAY TILE ADHESIVE AND MARK | | | PADDY SIZE. F)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON | | | ELEVATIONS. G)SPRAY FOAM INSULATION SPECIFIED ON | | | PLANS.(NOTE:PROVIDE ICC EVALUATION REPORT). | | | 11- ENGINEER OF RECORD TO REVIEW/APPROVE ALL PRODUCT | | | APPROVALS. | | | 12- PROVIDE COMPLETE DETAILS/SPECS FOR FUTURE CUSTOM | | | GLASS WINE ROOM ON A SEPARATE PERMIT. | | | 13- FUTURE ELEVATOR WILL BE ON A SEPARATE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-22 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-22 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2022-06-22 13:10:36 | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION/INSPECTIONS TO AVOID CONFLICTS/DELAYS): | | | | | | 1- PROVIDE COMPLETE FRAMING DETAILS/SPECS FOR ELEVATOR | | | SHAFT. SPECIFY ALL FRAMING MEMBERS/CONNECTORS, | | | INCLUDING BRACING TO SUPPORT THE ELEVATOR. | | | 2- PROVIDE COMPLETE DETAILS/SPECS FOR BALCONIES CLAY | | | TILE RAILING. SPECIFY ALL FRAMING MEMBERS/CONNECTORS | | | AND CLAY TILE INSTALLATION. | | | 3- PROVIDE COMPLETE DETAILS/SPECS FOR CANOPIES. SPECIFY | | | ALL FRAMING MEMBERS/CONNECTORS. | | | 4- PROVIDE COMPLETE FRAMING DETAILS/SPECS FOR TRELLIS | | | PERGOLA. SPECIFY ALL FRAMING MEMBERS/CONNECTORS. | | | 5- DESIGNER OF RECORD TO DEPICT THE BUILDING THERMAL | | | ENVELOPE. SPECIFY INSULATION R-VALUES. SEC. R103.2 | | | FBC-ENERGY CONSERVATION. | | | 6- REVISE ENERGY CALCULATIONS MAIN HOUSE. | | | A)PROVIDE INFORMATION: OWNER, BUILDER, PERMIT OFFICE & | | | JURISDICTION (JURISDICTION 604700).SEC. R101.5.1.1.2 | | | FBC- ENERGY CONSERVATION. | | | B)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH | | | PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | C)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | 7- REVISE ENERGY CALCULATIONS GUEST HOUSE. | | | A)PROVIDE INFORMATION: OWNER, BUILDER, PERMIT OFFICE & | | | JURISDICTION (JURISDICTION 604700).SEC. R101.5.1.1.2 | | | FBC- ENERGY CONSERVATION. B)REVISE FLOOR TYPES | | | INFORMATION. THE RAISED FLOOR IS THE GUEST SUITE. | | | REVISE AS REQUIRED. FLOOR AREAS ABOVE UNCONDITIONED | | | SPACE NEED TO HAVE INSULATION. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | C)REVISE SPACES INFORMATION. THERE IS NOT KITCHEN IN | | | THE GUEST SUITE. | | | D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | 8- REVISE LOT DRAINAGE PLAN: DETAIL SECTIONS A-A, B-B | | | AND C-C SHOW WATER RUNNING TO THE NEIGHBOR'S PROPERTY. | | | ALSO, PROVIDE INFORMATION SHOWING DRAINAGE ON THE EAST | | | SIDE OF POOL DECK. | | | 9- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | 10- PROVIDE PRODUCT APPROVAL FOR: A)ALL EXTERIOR DOORS. | | | B)WINDOWS. C)WINDOW MULLIONS (NOTE: SPECIFY MULLION | | | SIZE) D)ROOF CLAY TILE. E)CLAY TILE ADHESIVE AND MARK | | | PADDY SIZE. F)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON | | | ELEVATIONS. G)SPRAY FOAM INSULATION SPECIFIED ON | | | PLANS.(NOTE:PROVIDE ICC EVALUATION REPORT). | | | 11- ENGINEER OF RECORD TO REVIEW/APPROVE ALL PRODUCT | | | APPROVALS. | | | 12- PROVIDE COMPLETE DETAILS/SPECS FOR FUTURE CUSTOM | | | GLASS WINE ROOM ON A SEPARATE PERMIT. | | | 13- FUTURE ELEVATOR WILL BE ON A SEPARATE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-05-23 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-23 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2022-05-23 13:16:35 | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION/INSPECTIONS TO AVOID CONFLICTS/DELAYS): | | | | | | 1- PROVIDE COMPLETE FRAMING DETAILS/SPECS FOR ELEVATOR | | | SHAFT. SPECIFY ALL FRAMING MEMBERS/CONNECTORS, | | | INCLUDING BRACING TO SUPPORT THE ELEVATOR. | | | 2- PROVIDE COMPLETE DETAILS/SPECS FOR BALCONIES CLAY | | | TILE RAILING. SPECIFY ALL FRAMING MEMBERS/CONNECTORS | | | AND CLAY TILE INSTALLATION. | | | 3- PROVIDE COMPLETE DETAILS/SPECS FOR CANOPIES. SPECIFY | | | ALL FRAMING MEMBERS/CONNECTORS. | | | 4- PROVIDE COMPLETE FRAMING DETAILS/SPECS FOR TRELLIS | | | PERGOLA. SPECIFY ALL FRAMING MEMBERS/CONNECTORS. | | | 5- DESIGNER OF RECORD TO DEPICT THE BUILDING THERMAL | | | ENVELOPE. SPECIFY INSULATION R-VALUES. SEC. R103.2 | | | FBC-ENERGY CONSERVATION. | | | 6- REVISE ENERGY CALCULATIONS MAIN HOUSE. | | | A)PROVIDE INFORMATION: OWNER, BUILDER, PERMIT OFFICE & | | | JURISDICTION (JURISDICTION 604700).SEC. R101.5.1.1.2 | | | FBC- ENERGY CONSERVATION. | | | B)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH | | | PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | C)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | 7- REVISE ENERGY CALCULATIONS GUEST HOUSE. | | | A)PROVIDE INFORMATION: OWNER, BUILDER, PERMIT OFFICE & | | | JURISDICTION (JURISDICTION 604700).SEC. R101.5.1.1.2 | | | FBC- ENERGY CONSERVATION. B)REVISE FLOOR TYPES | | | INFORMATION. THE RAISED FLOOR IS THE GUEST SUITE. | | | REVISE AS REQUIRED. FLOOR AREAS ABOVE UNCONDITIONED | | | SPACE NEED TO HAVE INSULATION. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | C)REVISE SPACES INFORMATION. THERE IS NOT KITCHEN IN | | | THE GUEST SUITE. | | | D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | 8- REVISE LOT DRAINAGE PLAN: DETAIL SECTIONS A-A, B-B | | | AND C-C SHOW WATER RUNNING TO THE NEIGHBOR'S PROPERTY. | | | ALSO, PROVIDE INFORMATION SHOWING DRAINAGE ON THE EAST | | | SIDE OF POOL DECK. | | | 9- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | 10- PROVIDE PRODUCT APPROVAL FOR: A)ALL EXTERIOR DOORS. | | | B)WINDOWS. C)WINDOW MULLIONS (NOTE: SPECIFY MULLION | | | SIZE) D)ROOF CLAY TILE. E)CLAY TILE ADHESIVE AND MARK | | | PADDY SIZE. F)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON | | | ELEVATIONS. G)SPRAY FOAM INSULATION SPECIFIED ON | | | PLANS.(NOTE:PROVIDE ICC EVALUATION REPORT). | | | 11- ENGINEER OF RECORD TO REVIEW/APPROVE ALL PRODUCT | | | APPROVALS. | | | 12- PROVIDE COMPLETE DETAILS/SPECS FOR FUTURE CUSTOM | | | GLASS WINE ROOM ON A SEPARATE PERMIT. | | | 13- FUTURE ELEVATOR WILL BE ON A SEPARATE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-05-23 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-23 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2022-05-23 10:39:10 | NEW SINGE FAMILY RESIDENCE (R3), 4TH BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21060227. | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | | | | 1- UNDER SEPARATE PERMIT. SEE ITEM #12 BELOW. | | | 1(G)PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | | ELEVATOR SHAFT. DETAIL 4 ON SHEET A7 IS MISSING ALL | | | STRUCTURAL FRAMING INFORMATION. SPECIFY ALL FRAMING | | | MEMBERS AND CONNECTORS, INCLUDING THE BRACING TO | | | SUPPORT THE ELEVATOR. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: SEE HOISTWAY PLAN #4 ON SHEET A7. | | | | | | ***PREVIOUS COMMENT. | | | RESPONSE TO ARCHITECTURAL PLANS SUBMITTED: | | | 2(A) DEFERRED SUBMITTAL: (NOTE: NEED TO PROVIDE | | | INFORMATION FOR REVIEW BEFORE INSTALLATION/INSPECTION | | | TO AVOID CONFLICTS/DELAYS): | | | PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR BALCONIES | | | CLAY TILE RAILING AS SHOWN ON PLANS. SPECIFY ALL | | | FRAMING MEMBERS AND ALL CONNECTORS. SPECIFY CLAY TILE | | | INSTALLATION. DETAIL 7 ON SHEET A7 IS MISSING ALL THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 2(B)DEFERRED SUBMITTAL: (NOTE: NEED TO PROVIDE | | | INFORMATION FOR REVIEW BEFORE INSTALLATION/INSPECTION | | | TO AVOID CONFLICTS/DELAYS): | | | PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR CANOPIES AS | | | SHOWN ON PLANS. SPECIFY ALL FRAMING MEMBERS AND | | | CONNECTORS. DETAIL 1 ON SHEET A7 IS MISSING THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 2(C)DEFERRED SUBMITTAL: (NOTE: NEED TO PROVIDE | | | INFORMATION FOR REVIEW BEFORE INSTALLATION/INSPECTION | | | TO AVOID CONFLICTS/DELAYS): | | | PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | | TRELLIS PERGOLA. SPECIFY ALL FRAMING MEMBERS AND | | | CONNECTORS. ARBOR DETAIL 4 ON SHEET A5 IS MISSING THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 3- OK. | | | | | | ORIGINAL COMMENT: | | | 4- DESIGNER OF RECORD TO NEEDS TO DEPICT THE BUILDING | | | THERMAL ENVELOPE AND SPECIFY INSULATION MATERIALS AND | | | THEIR R-VALUES. | | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. THIS IS NOT A DEFERRED ITEM. DESIGNER | | | OF RECORD TO SPECIFY THE R-VALUE FOR CEILING, WALLS, | | | FLOOR/CEILING ASSEMBLY BETWEEN GARAGE AND GUEST SUITE | | | ABOVE. | | | NOTE: COORDINATE WITH ENERGY CALCULATIONS TO AVOID | | | CONFLICTS/DELAYS. | | | | | | ORIGINAL COMMENT: | | | 5-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. COORDINATE WITH PLANS | | | TO AVOID CONFLICTS/DELAYS. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | RESPONSE: | | | ENERGY CALCULATIONS SUBMITTED MAIN HOUSE: | | | A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER'S NAME, BUILDER'S NAME, PERMIT OFFICE | | | AND JURISDICTION (THIS JURISDICTION IS 604700). SEC. | | | R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | B)WINDOWS OVERHANG DEPTH AND SEPARATION ON PAGE 3 DON'T | | | MATCH PLANS. SEE PLANS AND REVISE AS REQUIRED TO MATCH | | | PLANS. SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | C)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 6- LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | DETAIL SECTIONS A-A, B-B AND C-C ON SITE ENGINEERING | | | PLAN SUBMITTED SHOW WATER RUNNING TO THE NEIGHBOR'S | | | PROPERTY. THE WATER NEEDS TO BE CONTAINED WITHIN THE | | | LOT AND/OR DIVERTED TO AN APPROVED POINT OF COLLECTION | | | OR TOWARDS THE STREET. ALSO, THE PROPOSED POOL DECK IS | | | TOO CLOSE TO THE NEIGHBOR'S PROPERTY AND THERE IS NOT | | | INFORMATION SHOWING HOW THE WATER WILL REMAIN WITHIN | | | THIS LOT IN THIS AREA. REVISE AS REQUIRED. ALSO, | | | MISSING SECTION FOR FRONT OF THE LOT. | | | SEC. 110 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 7- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | DEFERRED SUBMITTAL: | | | 8-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL): | | | A)ALL EXTERIOR DOORS. | | | B)WINDOWS. | | | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE | | | TO AVOID DELAYS/CONFLICTS). | | | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | E)CLAY TILE ROOF (3:12 PITCH). | | | F)CLAY TILE ADHESIVE (IF SPECIFIED ON PLANS) AND MARK | | | PADDY SIZE. | | | G)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON ELEVATIONS. | | | H)SPRAY FOAM INSULATION SPECIFIED ON | | | PLANS.(NOTE:PROVIDE ICC EVALUATION REPORT). | | | | | | 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 10- OK. | | | | | | 11- FUTURE CUSTOM GLASS WINE ROOM WILL BE ON A SEPARATE | | | PERMIT. | | | | | | 12- FUTURE ELEVATOR WILL BE ON A SEPARATE PERMIT. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-06 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-06 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2022-04-06 16:43:36 | NEW SINGE FAMILY RESIDENCE (R3), THIRD BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21060227. | | | | | | 1- UNDER SEPARATE PERMIT. SEE ITEM #12 BELOW. | | | 1(G)PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | | ELEVATOR SHAFT. DETAIL 4 ON SHEET A7 IS MISSING ALL | | | STRUCTURAL FRAMING INFORMATION. SPECIFY ALL FRAMING | | | MEMBERS AND CONNECTORS, INCLUDING THE BRACING TO | | | SUPPORT THE ELEVATOR. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: SEE HOISTWAY PLAN #4 ON SHEET A7. | | | | | | ***PREVIOUS COMMENT. | | | RESPONSE TO ARCHITECTURAL PLANS SUBMITTED: | | | 2(A) DEFERRED SUBMITTAL: (NOTE: NEED TO PROVIDE | | | INFORMATION FOR REVIEW BEFORE INSTALLATION/INSPECTION | | | TO AVOID CONFLICTS/DELAYS): | | | PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR BALCONIES | | | CLAY TILE RAILING AS SHOWN ON PLANS. SPECIFY ALL | | | FRAMING MEMBERS AND ALL CONNECTORS. SPECIFY CLAY TILE | | | INSTALLATION. DETAIL 7 ON SHEET A7 IS MISSING ALL THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 2(B)DEFERRED SUBMITTAL: (NOTE: NEED TO PROVIDE | | | INFORMATION FOR REVIEW BEFORE INSTALLATION/INSPECTION | | | TO AVOID CONFLICTS/DELAYS): | | | PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR CANOPIES AS | | | SHOWN ON PLANS. SPECIFY ALL FRAMING MEMBERS AND | | | CONNECTORS. DETAIL 1 ON SHEET A7 IS MISSING THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 2(C)DEFERRED SUBMITTAL: (NOTE: NEED TO PROVIDE | | | INFORMATION FOR REVIEW BEFORE INSTALLATION/INSPECTION | | | TO AVOID CONFLICTS/DELAYS): | | | PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | | TRELLIS PERGOLA. SPECIFY ALL FRAMING MEMBERS AND | | | CONNECTORS. ARBOR DETAIL 4 ON SHEET A5 IS MISSING THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 3- OK. | | | | | | ORIGINAL COMMENT: | | | 4- DESIGNER OF RECORD TO NEEDS TO DEPICT THE BUILDING | | | THERMAL ENVELOPE AND SPECIFY INSULATION MATERIALS AND | | | THEIR R-VALUES. | | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. THIS IS NOT A DEFERRED ITEM. DESIGNER | | | OF RECORD TO SPECIFY THE R-VALUE FOR CEILING, WALLS, | | | FLOOR/CEILING ASSEMBLY BETWEEN GARAGE AND GUEST SUITE | | | ABOVE. | | | NOTE: COORDINATE WITH ENERGY CALCULATIONS TO AVOID | | | CONFLICTS/DELAYS. | | | | | | ORIGINAL COMMENT: | | | 5-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. COORDINATE WITH PLANS | | | TO AVOID CONFLICTS/DELAYS. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | RESPONSE: | | | ENERGY CALCULATIONS SUBMITTED: | | | A)CALCULATIONS NEED THE ORIGINAL SEAL AND SIGNATURE OF | | | THE ENGINEER AS REQUIRED BY CHAPTER 471 FLORIDA | | | STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR PUBLIC | | | RECORDS. | | | NOTE: SUBMIT CALCULATIONS ELECTRONICALLY WITH | | | ENGINEER'S DIGITAL SIGNATURE OR PROVIDE HARD COPY | | | CALCULATIONS WITH ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | B)SEPARATE ENERGY CALCULATIONS IS REQUIRED FOR EACH | | | BUILDING. MAIN HOUSE AND ACCESSORY STRUCTURE. SEC. | | | R101.3 FBC-ENERGY CONSERVATION. | | | | | | C)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER'S NAME, BUILDER'S NAME, PERMIT OFFICE | | | AND JURISDICTION (THIS JURISDICTION IS 604700). SEC. | | | R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | | | D)NUMBER OF BEDROOMS, CONDITIONED FLOOR AREA, WINDOWS | | | INFORMATION, FLOOR TYPES INFORMATION, WALL TYPES | | | INFORMATION, CEILING TYPES INFORMATION AND ALL | | | INFORMATION ON SUBSEQUENT PAGES NEED TO BE COORDINATED | | | WITH EACH BUILDING. SEE PLANS FOR INFORMATION ON EACH | | | BUILDING AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 | | | FBC-RESIDENTIAL. | | | NOTE: COORDINATE WITH ITEM 5(B) ABOVE. SEPARATE | | | BUILDINGS. | | | | | | E)WINDOWS OVERHANG DEPTH AND SEPARATION ON PAGE 3 DON'T | | | MATCH PLANS. SEE PLANS AND REVISE AS REQUIRED TO MATCH | | | PLANS. SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | NOTE: COORDINATE WITH ITEM 5(B) ABOVE. SEPARATE | | | BUILDINGS. | | | | | | F)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD FOR EACH BUILDING. SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION. | | | | | | ORIGINAL COMMENT: | | | 6- LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | REPEAT COMMENT. THIS IS NOT A DEFFERED SUBMITTAL. THIS | | | INFORMATION IS REQUIRED NOW BECAUSE IT AFFECTS THE | | | CONSTRUCTION OF THE HOUSE. | | | NOTE: PROVIDE DRAINAGE PLAN. SHOW HOW THE EXISTING AND | | | PROPOSED GRADE ELEVATIONS WILL KEEP WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | ORIGINAL COMMENT: | | | 7- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | DEFERRED SUBMITTAL: | | | 8-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL): | | | A)ALL EXTERIOR DOORS. | | | B)WINDOWS. | | | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE | | | TO AVOID DELAYS/CONFLICTS). | | | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | E)CLAY TILE ROOF (3:12 PITCH). | | | F)CLAY TILE ADHESIVE (IF SPECIFIED ON PLANS) AND MARK | | | PADDY SIZE. | | | G)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON ELEVATIONS. | | | H)SPRAY FOAM INSULATION SPECIFIED ON | | | PLANS.(NOTE:PROVIDE ICC EVALUATION REPORT). | | | | | | 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 10- OK. | | | | | | 11- FUTURE CUSTOM GLASS WINE ROOM WILL BE ON A SEPARATE | | | PERMIT. | | | | | | 12- FUTURE ELEVATOR WILL BE ON A SEPARATE PERMIT. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-02-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-16 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-16 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2022-02-16 17:22:21 | NEW SINGE FAMILY RESIDENCE (R3), SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21060227. | | | | | | ORIGINAL COMMENT: | | | 1- STRUCTURAL DRAWINGS WERE NOT SUBMITTED. NEED TO | | | PROVIDE COMPLETE SET OF STRUCTURAL DRAWINGS. UNABLE TO | | | DO THE REVIEW. SEC. 107.2.1 CITY AMENDMENTS. | | | SPECIFY THE CURRENT CODE IN EFFECT. BUILDING EXPOSURE | | | (NOTE: THIS BUILDING IS LOCATED IN EXPOSURE "D". | | | ULTIMATE AND NOMINAL WIND SPEEDS. ALL LIVE AND DEAD | | | LOADS (INCLUDING ATTIC LIVE LOADS). ALL COMPONENTS AND | | | CLADDING DESIGN PRESSURES. SEC. R301.2.1 FBC | | | RESIDENTIAL. | | | | | | RESPONSE TO STRUCTURAL PLANS SUBMITTED: | | | 1(A)THERE IS A CONCERN ABOUT THE SUPPORT OF THE SECOND | | | FLOOR GIRDER TRUSS RUNNING FROM THE STAIRWAY TO THE | | | WALL BETWEEN THE FUTURE BUTLER'S PANTRY AND FUTURE WINE | | | ROOM. FOUNDATION PLAN ON SHEET S1 SPECIFIES WD1 COLUMN | | | ON ONE END AND FIRST FLOOR LIFT BEAM PLAN ON SHEET S2 | | | SPECIFIES DOUBLE 2X6 STUD ON THE OTHER END. PROVIDE | | | CALCULATIONS SHOWING THAT THE PROPOSED WOOD COLUMNS | | | (10' HIGH) ARE ADEQUATE TO SUPPORT ALL THE SECOND FLOOR | | | LOADS. SEC. R301.1 FBC-RESIDENTIAL, SEC. 107.2.1.2 CITY | | | AMENDMENTS. | | | | | | 1(B)CLARIFY WHY FOOTER FOR GIRDER TRUSS MENTIONED ABOVE | | | WAS ENLARGED AT THE DOUBLE 2X6 COLUMN, BUT IT WAS NOT | | | ENLARGED AT THE WD1 COLUMN?. SEC. 107.2.1.2 CITY | | | AMENDMENTS. | | | | | | 1(C)FIRST FLOOR LIFT BEAM PLAN ON SHEET S2 SHOWS THAT | | | GIRDER TRUSS MENTIONED ABOVE IS NOT RESTING ON TOP OF | | | WD1 COLUMN. THE SUPPORT IS OFFSET. PROVIDE | | | DETAIL/SPECIFICATIONS FOR THIS TRUSS TO POST | | | CONNECTION. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | 1(D)BASED ON TABLE R301.2(2) FBC-RESIDENTIAL, THE | | | COMPONENTS AND CLADDING WIND LOADS SPECIFIED ON SHEETS | | | A-3 AND A-4 ARE TOO LOW. REVISE AS REQUIRED OR PROVIDE | | | ACTUAL CALCULATIONS. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | 1(E)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR TOP AND | | | BOTTOM CONNECTIONS OF 8X8 AND 12X12 WOOD COLUMNS SHOWN | | | ON THE SECOND FLOOR BALCONIES. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | NOTE: 12X12 COLUMNS ARE RESTING ON CONCRETE. 8X8 | | | COLUMNS ARE RESTING ON CANTILEVER WOOD BALCONY DECK. | | | | | | 1(F)PROVIDE COMPLETE FRAMING DETAILS FOR SECOND FLOOR | | | FRENCH DOORS BY THE MASTER SUITE BALCONY. SPECIFY ALL | | | FRAMING MEMBERS AND CONNECTORS. SEC. R301.1 | | | FBC-RESIDENTIAL, SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | 1(G)PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | | ELEVATOR SHAFT. DETAIL 4 ON SHEET A7 IS MISSING ALL | | | STRUCTURAL FRAMING INFORMATION. SPECIFY ALL FRAMING | | | MEMBERS AND CONNECTORS, INCLUDING THE BRACING TO | | | SUPPORT THE ELEVATOR. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: SEE HOISTWAY PLAN #4 ON SHEET A7. | | | | | | ORIGINAL COMMENT: | | | 2- ARCHITECTURAL PLANS ARE INCOMPLETE. SEC. 107.2.1 | | | CITY AMENDMENTS. | | | NEED THE FOLLOWING: TO SHOW THE DIMENSIONS OF ALL ROOMS | | | AND AREAS; DOORS AND WINDOWS SCHEDULES; BEDROOMS | | | EMERGENCY EGRESS, SECOND FLOOR WINDOW FALL PROTECTION | | | (IF REQUIRED); COMPLETE CONSTRUCTION DETAILS AND | | | SPECIFICATIONS FOR ALL STAIRWAYS, HANDRAILS AND | | | GUARDRAILS; COMPLETE DETAILS AND SPECIFICATIONS FOR | | | FIREPLACE; COMPLETE DETAILS AND SPECIFICATIONS FOR POOL | | | TRELLIS CONSTRUCTION; COMPLETE DETAILS AND | | | SPECIFICATIONS FOR ROOF VENTILATION; COMPLETE DETAILS | | | AND SPECIFICATIONS FOR ROOF CLAY TILE INSTALLATION AND | | | ROOFING UNDERLAYMENT; SPECIFY FASTENING; FIRE RATED | | | CONSTRUCTION ABOVE GARAGE; COMPLETE DETAILS AND | | | SPECIFICATIONS FOR FIREBLOCKING AND DRAFSTOPPING; | | | COMPLETE DETAILS AND SPECIFICATIONS FOR CANOPY AND | | | AWNING CONSTRUCTION SHOWN ON PLANS; COMPLETE DETAILS | | | AND SPECIFICATIONS FOR CARPORT CONSTRUCTION SHOWN ON | | | PLANS; ATTIC ACCESS SIZE; COMPLETE EQUIPMENT ALUMINUM | | | SCREENINGS DETAILS AND SPECIFICATIONS; COMPLETE DETAILS | | | AND SPECIFICATIONS FOR CLAY TILE GUARDRAIL SYSTEM SHOWN | | | ON EXTERIOR ELEVATIONS; GARAGE STRUCTURAL BUCK DETAIL; | | | DOORS AND WINDOWS STRUCTURAL BUCK DETAILS; COMPLETE | | | DETAILS AND SPECIFICATIONS FOR ELEVATOR SHAFT | | | CONSTRUCTION AND FOR ELEVATOR TO BE INSTALLED; CARBON | | | MONOXIDE ALARMS, ETC. | | | | | | RESPONSE TO ARCHITECTURAL PLANS SUBMITTED: | | | 2(A)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR | | | BALCONIES CLAY TILE RAILING AS SHOWN ON PLANS. SPECIFY | | | ALL FRAMING MEMBERS AND ALL CONNECTORS. SPECIFY CLAY | | | TILE INSTALLATION. DETAIL 7 ON SHEET A7 IS MISSING ALL | | | THIS INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: THIS COULD BE A DEFERRED SUBMITTAL. | | | | | | 2(B)PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR | | | CANOPIES AS SHOWN ON PLANS. SPECIFY ALL FRAMING MEMBERS | | | AND CONNECTORS. DETAIL 1 ON SHEET A7 IS MISSING THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: THIS COULD BE A DEFERRED SUBMITTAL. | | | | | | 2(C)PROVIDE COMPLETE FRAMING DETAILS/SPECIFICATIONS FOR | | | TRELLIS PERGOLA. SPECIFY ALL FRAMING MEMBERS AND | | | CONNECTORS. ARBOR DETAIL 4 ON SHEET A5 IS MISSING THIS | | | INFORMATION. SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: THIS COULD BE A DEFERRED SUBMITTAL. | | | | | | 2(D) DOORS AND WINDOWS STRUCTURAL BUCK INFORMATION | | | SHOWN ON SHEET D1 AND DOORS AND WINDOWS STRUCTURAL BUCK | | | INFORMATION SHOWN ON SHEET S11 DON'T MATCH. REVISE AS | | | REQUIRED TO MATCH TO AVOID CONFLICTS/DELAYS. SEC. | | | 107.21 CITY AMENDMENTS. | | | | | | 3- OK. | | | | | | ORIGINAL COMMENT: | | | 4- DESIGNER OF RECORD TO NEEDS TO DEPICT THE BUILDING | | | THERMAL ENVELOPE AND SPECIFY INSULATION MATERIALS AND | | | THEIR R-VALUES. | | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | DESIGNER OF RECORD TO SPECIFY THE R-VALUE FOR CEILING, | | | WALLS, FLOOR/CEILING ASSEMBLY BETWEEN GARAGE AND GUEST | | | SUITE ABOVE. | | | | | | ORIGINAL COMMENT: | | | 5-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. COORDINATE WITH PLANS | | | TO AVOID CONFLICTS/DELAYS. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 6- LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | ORIGINAL COMMENT: | | | 7- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 8-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)ALL EXTERIOR DOORS. | | | B)WINDOWS. | | | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE | | | TO AVOID DELAYS/CONFLICTS). | | | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | E)CLAY TILE ROOF (3:12 PITCH). | | | F)CLAY TILE ADHESIVE (IF SPECIFIED ON PLANS) AND MARK | | | PADDY SIZE. | | | G)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON ELEVATIONS. | | | | | | RESPONSE: | | | NOT ADDRESSED. PLEASE ADVICE IF SUBMITTING LATER AS A | | | SUBMITTAL. | | | | | | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 10- SEPARATE PERMIT APPLICATION FOR EACH BUILDING. | | | PLEASE SUBMIT A SEPARATE PERMIT APPLICATION (AND | | | SUB-PERMIT APPLICATIONS) FOR THE SEPARATE GARAGE/GUEST | | | SUITE BUILDING. SAME PLANS CAN BE USED. SEPARATE PERMIT | | | APPLICATIONS HELP TO COORDINATE INSPECTIONS FOR EACH | | | BUILDING AND TO FACILITATE RECORDS KEEPING. SEC. | | | 107.2.1.3 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | 11- FUTURE CUSTOM GLASS WINE ROOM WILL BE ON A SEPARATE | | | PERMIT. | | | | | | 12- FUTURE ELEVATOR WILL BE ON A SEPARATE PERMIT. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-27 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-27 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2021-07-27 10:15:48 | NEW SINGE FAMILY RESIDENCE (R3), BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21060227. | | | | | | 1- STRUCTURAL DRAWINGS WERE NOT SUBMITTED. NEED TO | | | PROVIDE COMPLETE SET OF STRUCTURAL DRAWINGS. UNABLE TO | | | DO THE REVIEW. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | A)SPECIFY THE CURRENT CODE IN EFFECT. | | | B)BUILDING EXPOSURE (NOTE: THIS BUILDING IS LOCATED IN | | | EXPOSURE "D" | | | C)ULTIMATE AND NOMINAL WIND SPEEDS. | | | D)ALL LIVE AND DEAD LOADS (INCLUDING ATTIC LIVE LOADS). | | | E)ALL COMPONENTS AND CLADDING DESIGN PRESSURES. | | | SEC. R301.2.1 FBC RESIDENTIAL. | | | | | | 2- ARCHITECTURAL PLANS ARE INCOMPLETE. SEC. 107.2.1 | | | CITY AMENDMENTS. | | | NEED THE FOLLOWING: TO SHOW THE DIMENSIONS OF ALL ROOMS | | | AND AREAS; DOORS AND WINDOWS SCHEDULES; BEDROOMS | | | EMERGENCY EGRESS, SECOND FLOOR WINDOW FALL PROTECTION | | | (IF REQUIRED); COMPLETE CONSTRUCTION DETAILS AND | | | SPECIFICATIONS FOR ALL STAIRWAYS, HANDRAILS AND | | | GUARDRAILS; COMPLETE DETAILS AND SPECIFICATIONS FOR | | | FIREPLACE; COMPLETE DETAILS AND SPECIFICATIONS FOR POOL | | | TRELLIS CONSTRUCTION; COMPLETE DETAILS AND | | | SPECIFICATIONS FOR ROOF VENTILATION; COMPLETE DETAILS | | | AND SPECIFICATIONS FOR ROOF CLAY TILE INSTALLATION AND | | | ROOFING UNDERLAYMENT; SPECIFY FASTENING; FIRE RATED | | | CONSTRUCTION ABOVE GARAGE; COMPLETE DETAILS AND | | | SPECIFICATIONS FOR FIREBLOCKING AND DRAFSTOPPING; | | | COMPLETE DETAILS AND SPECIFICATIONS FOR CANOPY AND | | | AWNING CONSTRUCTION SHOWN ON PLANS; COMPLETE DETAILS | | | AND SPECIFICATIONS FOR CARPORT CONSTRUCTION SHOWN ON | | | PLANS; ATTIC ACCESS SIZE; COMPLETE EQUIPMENT ALUMINUM | | | SCREENINGS DETAILS AND SPECIFICATIONS; COMPLETE DETAILS | | | AND SPECIFICATIONS FOR CLAY TILE GUARDRAIL SYSTEM SHOWN | | | ON EXTERIOR ELEVATIONS; GARAGE STRUCTURAL BUCK DETAIL; | | | DOORS AND WINDOWS STRUCTURAL BUCK DETAILS; COMPLETE | | | DETAILS AND SPECIFICATIONS FOR ELEVATOR SHAFT | | | CONSTRUCTION AND FOR ELEVATOR TO BE INSTALLED; CARBON | | | MONOXIDE ALARMS, ETC. | | | | | | 3-NEED TO PROVIDE PLANS DRAWN TO A MINIMUM OF 1/8 INCH | | | SCALE. | | | SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | 4- DESIGNER OF RECORD TO NEEDS TO DEPICT THE BUILDING | | | THERMAL ENVELOPE AND SPECIFY INSULATION MATERIALS AND | | | THEIR R-VALUES. | | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | | | | | 5-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. COORDINATE WITH PLANS | | | TO AVOID CONFLICTS/DELAYS. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | 6- LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | 7- PROVIDE SURVEY SHOWING PROPOSED BUILDINGS AND | | | SETBACKS. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | | | | 8-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)EXTERIOR DOORS. | | | B)WINDOWS. | | | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE | | | TO AVOID DELAYS/CONFLICTS). | | | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | E)CLAY TILE ROOF (3:12 PITCH). | | | F)CLAY TILE ADHESIVE (IF SPECIFIED ON PLANS) AND MARK | | | PADDY SIZE. | | | G)CLAY TILE FOR GUARDRAIL SYSTEM SHOWN ON ELEVATIONS. | | | | | | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 10- SEPARATE PERMIT APPLICATION FOR EACH BUILDING. | | | PLEASE SUBMIT A SEPARATE PERMIT APPLICATION (AND | | | SUB-PERMIT APPLICATIONS) FOR THE SEPARATE GARAGE/GUEST | | | SUITE BUILDING. SAME PLANS CAN BE USED. SEPARATE PERMIT | | | APPLICATIONS HELP TO COORDINATE INSPECTIONS FOR EACH | | | BUILDING AND TO FACILITATE RECORDS KEEPING. SEC. | | | 107.2.1.3 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-07 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-07 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-09 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-09 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2022-05-09 09:18:55 | ELECTRIC REVIEW FAILED | | | 1) PLEASE PROVIDE DETAILS FOR ATS, RATINGS, OVERCURRENT | | | PROTECTION. 215.5 | | | 2) PLEASE PROVIDE AN ELECTRIC RECEPTACLE FOR SECOND | | | BASIN IN BATH #3. 210.52(D) | | | 3) PLEASE PROVIDE A NOTE STATING ELEVATOR, GENERATOR, | | | POOL AND LOW VOLTAGE LIGHTING REQUIRE SEPERATE PERMITS. | | | FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-04-05 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-04-05 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2022-04-05 08:06:23 | PLEASE READ COMMENTS FROM LAST TWO REVIEWS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-01-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-29 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-29 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2022-01-29 12:34:04 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) NO RISER DIAGRAM SHOWN 215.5 | | | | | | 2) NO LOAD CALCULATION SUBMITTED. 215.5 | | | | | | 3) MASTRE BATH HAS PENDANT FIXTURE OVER TUB, NOT | | | ALLOWED 410.10(D) | | | | | | (D) BATHTUB AND SHOWER AREAS. NO PARTS OF | | | CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, OR | | | CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK, PENDANTS, OR | | | CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED WITHIN | | | A ZONE MEASURED 900 MM (3 FT) HORIZONTALLY AND 2.5 M (8 | | | FT) VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR | | | SHOWER STALL THRESHOLD. THIS ZONE IS ALL ENCOMPASSING | | | AND INCLUDES THE SPACE DIRECTLY OVER THE TUB OR SHOWER | | | STALL. LUMINAIRES LOCATED WITHIN THE ACTUAL OUTSIDE | | | DIMENSION OF THE BATHTUB OR SHOWER TO A HEIGHT OF 2.5 M | | | (8 FT) VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR | | | SHOWER THRESHOLD SHALL BE MARKED FOR DAMP LOCATIONS, OR | | | MARKED FOR WET LOCATIONS WHERE SUBJECT TO SHOWER SPRAY. | | | | | | 4) PANEL SCHEDULE(S) REQUIRED TO VERUFY LOADS IN LOAD | | | CALCLUATION 215.5 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-07-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-01 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-01 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2021-07-01 17:06:04 | NO ELECTRICAL PLAN SUBMITTED JLEAHY |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-31 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-31 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-26 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-26 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2022-04-26 12:15:09 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 22031166 | | | 4/26/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. PLEASE NOTE THAT GAS CAN | | | BE UNDER SEPARATE PERMIT IF REQUESTED BY THE GENERAL | | | CONTRACTOR OF RECORD. | | | | | | 1) SHEET P401: PLEASE NOTE THAT SEPARATE PERMITS ARE | | | REQUIRED FOR INSTALLATION OF THE GENERATOR AND POOL | | | HEATER HOWEVER THE GENERATOR, AS SHOWN ON THE PLAN, | | | SHALL BE RELOCATED TO BE A MINIMUM OF 10-FT AWAY FROM | | | THE GARAGE WINDOW OPENING. PLEASE CORRECT THE PLANS AND | | | THE RISER DRAWING- SEC. R305.5.1 FBC RES. | | | | | | 2) P401: REFER TO SEC. G2411.1- G2411.3 FBC RES AND, | | | PROVIDE A NOTE OR DETAIL INDICATING HOW THE CSST PIPE | | | WILL BE ELECTRICALLY CONTINUOUS AND BONDED TO AN | | | EFFECTIVE GROUND FAULT CURRENT PATH. PLEASE SUBMIT | | | MANUFACTURER?S SPECIFICATIONS FOR THE PIPING- SEC. | | | G2414.5.4 FBC RES. | | | | | | 3) P401: PLACE A NOTE OR PROVIDE A DETAIL THAT THE | | | GAS-FIRED TANKLESS WATER HEATER WILL BE ELEVATED A | | | MINIMUM OF 18-INCHES ABOVE THE GARAGE FLOOR, OR A | | | MINIMUM OF 6FT. IF NOT PROTECTED FROM VEHICLE IMPACT- | | | SECS. G2408.2 & G2408.3 FBC RES. | | | | | | 4) P401: PROVIDE COMBUSTION AIR PLANS AND CALCULATIONS | | | FOR THE WATER HEATER, RANGE, AND DRYERS- SEC. G2407.1 | | | FBC RES. INDICATE HOW MAKEUP AIR WILL BE PROVIDED FOR | | | THE DRYERS- SEC. G2439.5 FBC RES. | | | | | | 5) P401: PROVIDE A VENTING DIAGRAM FOR THE WATER | | | HEATER- SEC. G2427.1 & G2448.1 FBC RES. SHOW THE TYPE | | | AND SIZE OF VENT DUCT, TOTAL DUCT RUN, AND TERMINATION | | | LOCATION WITH REQUIRED CAP AND CLEARANCE DISTANCE | | | MEASUREMENTS- G2427.8 FBC RES. | | | | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYERS, | | | RANGE, AND WATER HEATER- SEC. G2439.1, G2447.1, & | | | G2448.1 FBC RES. | | | | | | 7) SUBMIT A GAS SUB-PERMIT APPLICATION- SEC.105.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-06-27 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-06-27 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-06-24 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-06-24 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-02-23 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-02-23 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-06-23 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-06-23 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-27 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-27 |
Time |
13:55 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-24 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-15 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-07 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-27 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-05-23 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-23 |
Time |
13:38 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-05-23 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-17 |
Time |
08:20 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-06 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-30 |
Time |
07:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-02-24 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-01-13 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-27 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-23 |
Time |
06:45 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-05-26 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-05-26 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-05-18 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2022-05-26 09:49:09 | RECEIPT MU-2022-023608 - $546.52 PAID | | 2022-05-18 15:31:53 | 5/18/22 EMAILED IMPACT FOR REVIEW PER DB-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-27 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-27 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2021-07-27 10:20:29 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-31 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-31 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-02 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-02 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-04 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-04 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2022-04-04 13:10:13 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21060227 | | | | | | CODES IN EFFECT: | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GARAGE AND THE LIVING SPACE ABOVE IS UNDER | | | PERMIT NUMBER 22031166. THE ENERGY CALCULATION | | | SUBMITTED FOR PERMIT NUMBER 21060227 INCLUDES THE | | | GARAGE AND LIVING SPACE ABOVE. THERE MUST BE A SEPARATE | | | ENERGY CALCULATION FOR THE GARAGE AND LIVING SPACE. | | | PLEASE PROVIDE A SEPARATE ENERGY CALCULATION FOR BOTH | | | THE MAIN HOUSE AND THE GARAGE WITH LIVING SPACE ABOVE. | | | | | | 2) 3RD TIME FOR THE FOLLOWING COMMENTS. | | | | | | PLEASE PROVIDE MECHANICAL DRAWINGS FOR THIS PROJECT. | | | FBC 107.2.1 | | | A MECHANICAL PLANS REVIEW COULD NOT BE STARTED WITH | | | THIS SUBMITTAL AS NO MECHANICAL DRAWINGS WERE | | | SUBMITTED. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-14 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-14 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2022-01-14 08:06:13 | PLEASE PROVIDE THE ENERGY CALCULATIONS. FBC EC | | | 101.5.1.1.2 | | | PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7.1 | | | PLEASE PROVIDE MECHANICAL DRAWINGS FOR THIS PROJECT. | | | FBC 107.2.1 | | | A MECHANICAL PLANS REVIEW COULD NOT BE STARTED WITH | | | THIS SUBMITTAL AS NOTHING FOR THE MECHANICAL SYSTEM WAS | | | SUBMITTED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-29 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-29 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2021-06-29 13:48:02 | PLEASE PROVIDE THE ENERGY CALCULATIONS. | | | PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. | | | PLEASE PROVIDE MECHANICAL DRAWINGS FOR THIS PROJECT. | | | FBC 107.2.1 | | | A MECHANICAL PLANS REVIEW COULD NOT BE STARTED WITH | | | THIS SUBMITTAL AS NOTHING FOR THE MECHANICAL SYSTEM WAS | | | SUBMITTED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-31 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-31 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-04-26 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-04-26 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-04-04 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-04-04 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2022-04-04 08:35:20 | 04/04/22 3RD PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE A PLUMBING ISOMETRIC RISER DIAGRAM | | | FOR SANITARY AND WATER PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | | | 2. THESE ARE MULTI-FAMILY DWELLINGS, AND WATER USERS | | | WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION | | | ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW | | | ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF | | | HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE | | | BACKFLOW DEVICE WILL BE NEEDED FOR THE WATER METER PER | | | THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND | | | THEIR CONNECTION CONTROL PROGRAM. | | | | | | 3. PLEASE PROVIDE THE SOURCE OF HOT WATER PER THE 2020 | | | FBC FBC R 2722.2. | | | | | | 4. THERE IS A STOVE SHOWN BUT NOT LABELED, IS IT GAS OR | | | ELECTIRIC, IF GAS PLEASE PROVIDE ISOMETRIC DIAGRAM. | | | NOTE: YOU MAY CHOOSE TO HAVE A GAS REVIEW DONE THIS | | | TIME AND ADDRESS THE COMMENT. THIS WILL HAVE THE GAS | | | APPROVE FOR A SUB PERMIT, OR IF YOU DECIDED NOT TO | | | ADDRESS THESE COMMENTS, PLEASE PUT A NOTE ON THE GAS | | | HEATER ( A SEPARATE PERMIT BY A LICENSED CONTRACTOR FOR | | | THE GAS SYSTEM). THEN PLEASE TAKE OFF ANY GAS SHOWN ON | | | PLANS; THESE COMMENTS CAN BE FORWARD TO THE GAS | | | CONTRACTOR FOR REFERENCE. AN N WILL BE PUT ON THIS | | | REVIEW, WHICH STANDS FOR NOT REQUIRED BUT, A SUB PERMIT | | | WON'T BE ISSUED UNIT A REVIEW IS DONE FOR THAT SUB | | | PERMIT, SO PLEASE BE ADVISED ON THIS PROCEDURE. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-01-14 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-01-14 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2022-01-14 07:32:22 | 01/14/22 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE A PLUMBING ISOMETRIC RISER DIAGRAM | | | FOR SANITARY AND WATER PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | | | 2. THESE ARE MULTI-FAMILY DWELLINGS, AND WATER USERS | | | WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION | | | ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW | | | ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF | | | HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE | | | BACKFLOW DEVICE WILL BE NEEDED FOR THE WATER METER PER | | | THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND | | | THEIR CONNECTION CONTROL PROGRAM. | | | | | | 3. PLEASE PROVIDE THE SOURCE OF HOT WATER PER THE 2020 | | | FBC FBC R 2722.2. | | | | | | 4. THERE IS A STOVE SHOWN BUT NOT LABELED, IS IT GAS OR | | | ELECTIRIC, IF GAS PLEASE PROVIDE ISOMETRIC DIAGRAM. | | | NOTE: YOU MAY CHOOSE TO HAVE A GAS REVIEW DONE THIS | | | TIME AND ADDRESS THE COMMENT. THIS WILL HAVE THE GAS | | | APPROVE FOR A SUB PERMIT, OR IF YOU DECIDED NOT TO | | | ADDRESS THESE COMMENTS, PLEASE PUT A NOTE ON THE GAS | | | HEATER ( A SEPARATE PERMIT BY A LICENSED CONTRACTOR FOR | | | THE GAS SYSTEM). THEN PLEASE TAKE OFF ANY GAS SHOWN ON | | | PLANS; THESE COMMENTS CAN BE FORWARD TO THE GAS | | | CONTRACTOR FOR REFERENCE. AN N WILL BE PUT ON THIS | | | REVIEW, WHICH STANDS FOR NOT REQUIRED BUT, A SUB PERMIT | | | WON'T BE ISSUED UNIT A REVIEW IS DONE FOR THAT SUB | | | PERMIT, SO PLEASE BE ADVISED ON THIS PROCEDURE. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-06 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-06 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2021-07-06 17:35:26 | 07/06/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE A PLUMBING ISOMETRIC RISER DIAGRAM | | | FOR SANITARY AND WATER PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | | | 2. THESE ARE MULTI-FAMILY DWELLINGS, AND WATER USERS | | | WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION | | | ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW | | | ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF | | | HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE | | | BACKFLOW DEVICE WILL BE NEEDED FOR THE WATER METER PER | | | THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND | | | THEIR CONNECTION CONTROL PROGRAM. | | | | | | 3. PLEASE PROVIDE THE SOURCE OF HOT WATER PER THE 2020 | | | FBC FBC R 2722.2. | | | | | | 4. THERE IS A STOVE SHOWN BUT NOT LABELED, IS IT GAS OR | | | ELECTIRIC, IF GAS PLEASE PROVIDE ISOMETRIC DIAGRAM. | | | NOTE: YOU MAY CHOOSE TO HAVE A GAS REVIEW DONE THIS | | | TIME AND ADDRESS THE COMMENT. THIS WILL HAVE THE GAS | | | APPROVE FOR A SUB PERMIT, OR IF YOU DECIDED NOT TO | | | ADDRESS THESE COMMENTS, PLEASE PUT A NOTE ON THE GAS | | | HEATER ( A SEPARATE PERMIT BY A LICENSED CONTRACTOR FOR | | | THE GAS SYSTEM). THEN PLEASE TAKE OFF ANY GAS SHOWN ON | | | PLANS; THESE COMMENTS CAN BE FORWARD TO THE GAS | | | CONTRACTOR FOR REFERENCE. AN N WILL BE PUT ON THIS | | | REVIEW, WHICH STANDS FOR NOT REQUIRED BUT, A SUB PERMIT | | | WON'T BE ISSUED UNIT A REVIEW IS DONE FOR THAT SUB | | | PERMIT, SO PLEASE BE ADVISED ON THIS PROCEDURE. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-07-01 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-07-01 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-06 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-06 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2022-04-06 17:30:13 | NEED TO PROVIDE COMPLETE ROOFING INFORMATION FOR REVIEW | | | PRIOR TO ISSUING THE ROOFING SUB-PERMIT. | | | | | | 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL): | | | A))CLAY TILE ROOF (3:12 PITCH). AND CLEARLY MARK | | | FASTENING METHOD. | | | B)CLAY TILE ADHESIVE (IF SPECIFIED ON CLAY TILE PRODUCT | | | APPROVAL) AND MARK PADDY SIZE. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-17 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2022-02-17 09:50:56 | ROOFING REVIEW: | | | | | | 1--PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)CLAY TILE ROOF (3:12 PITCH). | | | B)CLAY TILE ADHESIVE (IF SPECIFIED ON PLANS) AND MARK | | | PADDY SIZE. | | | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-27 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-27 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2021-07-27 10:19:37 | ROOFING REVIEW: | | | | | | 1--PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)CLAY TILE ROOF (3:12 PITCH). | | | B)CLAY TILE ADHESIVE (IF SPECIFIED ON PLANS) AND MARK | | | PADDY SIZE. | | | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
7 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-06-27 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-06-27 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
F |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-06-22 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-22 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2022-06-22 13:27:45 | SIGNATURE REVIEW: | | | | | | 1- DRAWINGS DON'T HAVE VERIFIABLE DIGITAL | | | SEAL/SIGNATURE BY THE ARCHITECT AND STRUCTURAL ENGINEER | | | OF RECORD. (NOTE: ALL MEP DRAWINGS DIGITAL SIGNATURE IS | | | OK). | | | ALL ARCHITECTURAL AND STRUCTURAL DRAWINGS NEED TO HAVE | | | VERIFIABLE DIGITAL SEAL/SIGNATURE AS REQUIRED BY | | | CHAPTER 481 F.S. AND CHAPTER 471 F.S. WHEN SUBMITTING | | | FOR PUBLIC RECORDS. | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH ARCHITECT'S | | | AND ENGINEER'S DIGITAL SIGNATURE OR PROVIDE HARD COPY | | | PLANS WITH ARCHITECT'S AND ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | | | | 05/27/22 | | | HARD COPY DRAWINGS 012 E101, 014 E201, 015 E202, 015.10 | | | P301, 015.11 P401, 015.3 M101, 015.4 M102, 015.5 M201, | | | 015.6 M202 AND 015.8 P101 REVISED ON 05/23/22 HAVE | | | ENGINEER'S SEAL AND WET SIGNATURE. JG. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-05-27 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-27 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2022-05-27 18:51:27 | SIGNATURE REVIEW: | | | | | | FROM PREVIOUS REVIEW: | | | 1- DRAWINGS DON'T HAVE ORIGINAL DIGITAL SEAL/SIGNATURE | | | BY THE ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. | | | (NOTE: ALL MEP DRAWINGS DIGITAL SIGNATURE IS OK). | | | ALL ARCHITECTURAL AND STRUCTURAL DRAWINGS NEED TO HAVE | | | ORIGINAL DIGITAL SEAL/SIGNATURE AS REQUIRED BY CHAPTER | | | 481 F.S. AND CHAPTER 471 F.S. WHEN SUBMITTING FOR | | | PUBLIC RECORDS. | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH ARCHITECT'S | | | AND ENGINEER'S DIGITAL SIGNATURE OR PROVIDE HARD COPY | | | PLANS WITH ARCHITECT'S AND ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | | | | 05/27/22 | | | HARD COPY DRAWINGS 012 E101, 014 E201, 015 E202, 015.10 | | | P301, 015.11 P401, 015.3 M101, 015.4 M102, 015.5 M201, | | | 015.6 M202 AND 015.8 P101 REVISED ON 05/23/22 HAVE | | | ENGINEER'S SEAL AND WET SIGNATURE. JG. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-05-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-05-19 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-19 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2022-05-19 10:46:42 | SIGNATURE REVIEW: | | | | | | 1- DRAWINGS DON'T HAVE ORIGINAL DIGITAL SEAL/SIGNATURE | | | BY THE ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. | | | (NOTE: ALL MEP DRAWINGS DIGITAL SIGNATURE IS OK). | | | ALL ARCHITECTURAL AND STRUCTURAL DRAWINGS NEED TO HAVE | | | ORIGINAL DIGITAL SEAL/SIGNATURE AS REQUIRED BY CHAPTER | | | 481 F.S. AND CHAPTER 471 F.S. WHEN SUBMITTING FOR | | | PUBLIC RECORDS. | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH ARCHITECT'S | | | AND ENGINEER'S DIGITAL SIGNATURE OR PROVIDE HARD COPY | | | PLANS WITH ARCHITECT'S AND ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | ARCHITECTS | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | | | | | | | | | 2022-05-02 12:56:53 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-06 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-06 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2022-04-06 17:40:27 | THIRD SIGNATURE REVIEW: | | | | | | 1- DRAWINGS DON'T HAVE ORIGINAL DIGITAL SEAL/SIGNATURE | | | BY THE ARCHITECT AND ENGINEER OF RECORD. ALL DRAWINGS | | | NEED TO HAVE ORIGINAL DIGITAL L SEAL/SIGNATURE AS | | | REQUIRED BY CHAPTER 481 F.S. AND CHAPTER 471 F.S. WHEN | | | SUBMITTING FOR PUBLIC RECORDS. | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH | | | ARCHITECT'S/ENGINEER'S DIGITAL SIGNATURE OR PROVIDE | | | HARD COPY PLANS WITH ARCHITECT'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | 2- ENERGY CALCULATIONS AND EQUIPMENT SIZING | | | CALCULATIONS DON'T HAVE ENGINEER'S ORIGINAL DIGITAL | | | SEAL/SIGNATURE. NEED TO HAVE ORIGINAL DIGITAL L | | | SEAL/SIGNATURE AS REQUIRED BY CHAPTER 471 F.S. WHEN | | | SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | ARCHITECTS | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-17 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2022-02-17 10:08:17 | SECOND SIGNATURE REVIEW: | | | | | | 1- DRAWINGS/DOCUMENTS DON'T HAVE ORIGINAL DIGITAL | | | SEAL/SIGNATURE BY THE ARCHITECT AND ENGINEER OF RECORD. | | | ALL DRAWINGS/DOCUMENTS NEED TO HAVE ORIGINAL DIGITAL L | | | SEAL/SIGNATURE AS REQUIRED BY CHAPTER 481 F.S. AND | | | CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR | | | PUBLIC RECORDS. | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH | | | ARCHITECT'S/ENGINEER'S DIGITAL SIGNATURE OR PROVIDE | | | HARD COPY PLANS WITH ARCHITECT'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | ARCHITECTS | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-29 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-29 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2021-06-29 13:51:42 | DOCUMENTS SUBMITTED DIGITALLY APPEAR TO HAVE A COPY OF | | | THE DESIGNERS SEAL, THERE IS NO SIGNATURE ON THE | | | DRAWINGS. PLEASE EITHER PROVIDE DIGITALLY SIGNED | | | DRAWINGS. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-06-27 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-06-27 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-04-04 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-04-04 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-02-23 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-02-23 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-06-23 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-06-23 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|