Plan Review Details - Permit 21051652
Plan Review Stops For Permit 21051652
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-07-14 Cont ID  
Sent By cpuell Date 2021-07-14 Time 10:43 Rev Time 0.00
Received By cpuell Date 2021-07-14 Time 10:43 Sent To  
Notes
2021-07-14 10:45:46ADDED SUITE 148

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-07-13 Cont ID  
Sent By cpuell Date 2021-07-13 Time 13:37 Rev Time 0.00
Received By cpuell Date 2021-07-13 Time 13:37 Sent To  
Notes
2021-07-13 13:38:30READ RESPONCE TO COMMENTS, SUITE 148 IS NOT CURRENTLY
 IN OUR SYSTEM, PLEASE PROVIDE A FLOOR PLAN FOR THE
 WHOLE FLOOR INCLUDING ANY OTHER SUITES ON THE FLOOR,
 PLEASE PROVIDE THE SUITE NUMBERS FOR THE OTHER SUITES
 ON THAT FLOOR. WHICH FLOOR LEVEL IS THIS SUITE ON?
 PLEASE EMAIL [email protected] WITH RESPONSES.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-05-28 Cont ID  
Sent By cpuell Date 2021-05-28 Time 15:35 Rev Time 0.00
Received By cpuell Date 2021-05-28 Time 15:35 Sent To  
Notes
2021-05-28 15:37:58SUITE 148 OR 148 E IS NOT CURRENTLY IN OUR SYSTEM,
 PLEASE PROVIDE A FLOOR PLAN FOR THE WHOLE FLOOR
 INCLUDING ANY OTHER SUITES ON THE FLOOR, PLEASE PROVIDE
 THE SUITE NUMBERS FOR THE OTHER SUITES ON THAT FLOOR.
 WHICH FLOOR LEVEL IS THIS SUITE ON? PLEASE EMAIL
 [email protected] WITH RESPONSES.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-07-14 Cont ID  
Sent By jwitmer Date 2021-07-14 Time 12:25 Rev Time 0.00
Received By jwitmer Date 2021-07-14 Time 12:15 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-06-21 Cont ID  
Sent By pvalenti Date 2021-06-21 Time 15:56 Rev Time 0.00
Received By pvalenti Date 2021-06-21 Time 15:56 Sent To  
Notes
2021-06-21 15:57:33****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-07-14 Cont ID  
Sent By jwitmer Date 2021-07-14 Time 12:27 Rev Time 0.00
Received By jwitmer Date 2021-07-14 Time 12:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-06-29 Cont ID  
Sent By jwitmer Date 2021-06-29 Time 11:31 Rev Time 0.00
Received By jwitmer Date 2021-06-29 Time 11:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-10 Cont ID  
Sent By jleahy Date 2021-06-10 Time 17:44 Rev Time 0.00
Received By jleahy Date 2021-06-10 Time 17:11 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 2 Status P Date 2021-12-15 Cont ID  
Sent By jleahy Date 2021-12-15 Time 09:01 Rev Time 0.00
Received By jleahy Date 2021-12-15 Time 09:01 Sent To  
Notes
2021-12-15 09:01:47CONTROL WIRING FOR ENERGY MANAGEMENT SYSTEM JLEAHY

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-06-11 Cont ID  
Sent By jleahy Date 2021-06-11 Time 15:04 Rev Time 0.00
Received By jleahy Date 2021-06-11 Time 15:04 Sent To  
Notes
2021-06-11 15:10:36VOICE, DATA AND TV JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-06-07 Cont ID  
Sent By pleduc Date 2021-06-07 Time   Rev Time 0.00
Received By pleduc Date 2021-06-04 Time 13:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-07-22 Time   Rev Time 0.00
Received By aoliver Date 2021-07-12 Time 12:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-06-29 Time 11:30 Rev Time 0.00
Received By cdecoeur Date 2021-05-28 Time 07:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-07-21 Cont ID  
Sent By medwards Date 2021-07-21 Time 13:39 Rev Time 0.00
Received By medwards Date 2021-07-21 Time 13:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-06-14 Cont ID  
Sent By medwards Date 2021-06-14 Time 08:26 Rev Time 0.00
Received By medwards Date 2021-06-14 Time 07:59 Sent To  
Notes
2021-06-14 08:27:041ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21051652
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS FOR THE NEW AHU?S. FBC EC 403.2.1
  
 2) PLEASE REMOVE ALL REFERENCES TO ALTERNATES. SUBMIT
 THE FINAL PLAN FOR REVIEW. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-22 Cont ID  
Sent By ccole Date 2021-07-22 Time 09:37 Rev Time 0.00
Received By ccole Date 2021-07-20 Time 18:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-16 Cont ID  
Sent By ccole Date 2021-06-16 Time 08:31 Rev Time 0.00
Received By ccole Date 2021-06-15 Time 16:29 Sent To  
Notes
2021-06-16 08:31:401ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21051652
 6/15/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P2.0 & P3.0: THE FLOOR DRAIN IN THE STG 114
 REQUIRES AN INDIVIDUAL VENT BECAUSE IT CANNOT BE PART
 OF THE BATHROOM WET VENT SYSTEM- SECTION 912.1 FBC P.
  
 2) P1.0 & P3.0: RELOCATE THE FLOOR DRAIN FROM BELOW THE
 WATER HEATER- SECTION 504.7 FBC P.
  
 3) P4.0: PROVIDE A PAN AND PAN DRAIN FOR THE WATER
 HEATER- SECTION 504.7 FBC P.
  
 4) P4.0: PROVIDE THE EFFICIENCY RATING OF THE WATER
 HEATER- TABLE C404.2 FBC EC.
  
 5) P1.0: PROVIDE A SLAB REPAIR DETAIL- SECTION 107.2.1
 WPB.
  
 6) A3.1.2: IT IS ACKNOWLEDGED THAT THE NEW BATHROOM IS
 FOR PRIVATE AND PUBLIC USE, HOWEVER COMPLIANCE WITH THE
 FBC-2020 ACC CODE IN SPECIFIC AREAS IS REQUIRED AS
 OUTLINED BELOW. PLEASE PROVIDE THESE MISSING COMPLIANCE
 DETAILS:
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 WATER CLOSET- SECTION 604.3.
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORY- SECTION 606.2.
 C) TURNING SPACE DIAGRAM AND DIMENSIONS- SECTION 304.3.
 D) THE LENGTHS OF THE GRAB BAR REINFORCEMENTS FOR THE
 WATER CLOSETS- FIGURES 604.5.1 & 604.5.2.
 E) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 REFLECTIVE SURFACE- SECTION 603.3
 F) LENGTH MEASUREMENT OF THE SHOWER- SECTION 608.2.2
 G) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 SHOWER- SECTION 608.2.1
 H) LOCATIONS AND LENGTHS OF GRAB BAR REINFORCEMENTS FOR
 THE SHOWER- FIGURES 608.3.2 & 608.5.2.
 I) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE
 SHOWER- SECTION 608.5.1.
 J) SHOWER SPRAY UNIT SPECIFICATIONS PER SECTION 608.6.
 K) GRAB BAR REINFORCEMENT DETAIL SHOWING THE TYPE OF
 REINFORCEMENT MATERIALS TO BE INSTALLED, THE WIDTH AND
 THICKNESSES OF THE MATERIAL, FASTENING DETAILS- SEE
 SECTION 609.8.
  
 7) A5.1.1 DETAIL 16/A5.1.1: THE SHOWER PAN LINER SHALL
 BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2-PERCENT SLOPE). PLEASE CORRECT THE 1/8-
 INCH PER FT. SLOPE NOTE- SECTION 421.5.2 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-21 Cont ID  
Sent By medwards Date 2021-07-21 Time 13:41 Rev Time 0.00
Received By medwards Date 2021-07-21 Time 13:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-14 Cont ID  
Sent By medwards Date 2021-06-14 Time 08:34 Rev Time 0.00
Received By medwards Date 2021-06-14 Time 08:34 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved