Plan Review Details - Permit 21051635
Plan Review Stops For Permit 21051635
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-25 Cont ID  
Sent By ccole Date 2021-10-25 Time 16:32 Rev Time 0.00
Received By ccole Date 2021-10-25 Time 16:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-08-24 Cont ID  
Sent By ccole Date 2021-08-24 Time 16:22 Rev Time 0.00
Received By ccole Date 2021-08-24 Time 15:10 Sent To  
Notes
2021-08-24 16:22:561ST REVIEW FBC- 2020 RES. BUILDING.
 PERMIT- 21051635
 8/24/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED
  
 1) SUBMIT A FLORIDA PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE ROOF TILE SYSTEM. THE SUBMITTAL SHALL BE MARKED
 OR HIGHLIGHTED TO SHOW THE TYPE OF TILE AND ANCHORING
 METHOD- MECHANICAL OR ADHESIVE- FAC RULE 9N-3. PLEASE
 NOTE THAT PRODUCT APPROVALS OR NOA?S ARE REQUIRED FOR
 MANUFACTURED UNDERLAYMENT AND TILE ADHESIVE.
  
 2) SHEET S-01: PROVIDE FASTENER SCHEDULES FOR THE HGUM
 5.25 GIRDER HANGERS, AND THE HTS-20 AND THE HTSM-20
 STRAPS- SECTION 802.3.1 & 802.11 FBC RES.
  
 3) REFER TO SECTION R802.7.2 AND PROVIDE MANUFACTURER'S
 SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR THE
 VERSA LAM BEAM.
  
 3) S-01: INDICATE HOW THE CEILING WILL BE FINISHED.
 WHAT TYPE OF MATERIAL TO BE INSTALLED AND FASTENING
 SCHEDULE- R804.3.7.
  
 4) S-01: SHOW HOW THE EXPOSED ATTIC OPENINGS AT THE NEW
 AND OLD ROOF CONNECTIONS WILL BE ENCLOSED- R806.1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-08-24 Time   Rev Time 0.00
Received By ccarvaja Date 2021-08-23 Time 14:43 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2021-10-25 Cont ID  
Sent By ccole Date 2021-10-25 Time 16:34 Rev Time 0.00
Received By ccole Date 2021-10-25 Time 16:34 Sent To  
Notes
2021-10-25 16:34:34ROOF UNDER PERMIT 21081334.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-09-13 Cont ID  
Sent By ccole Date 2021-09-13 Time 09:23 Rev Time 0.00
Received By ccole Date 2021-08-24 Time 09:23 Sent To  
Notes
2021-09-13 09:24:131ST REVIEW FBC-2020 RES. BUILDING.
 PERMIT- 21051635
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FAC RULE 9N-3: PROVIDE FL. PRODUCT APPROVALS AND/OR
 MIAMI-DADE NOAS FOR THE TILE ROOFING WITH THE
 INSTALLATION METHOD AND DESIGN PRESSURES MARKED UP OR
 HIGHLIGHTED. PLEASE NOTE THAT A MARKED UP PRODUCT
 APPROVAL OR NOA IS REQUIRED FOR ADHESIVE IF USED.
 2) INDICATE THE TYPE OF UNDERLAYMENT TO BE INSTALLED.
 IF USING A MANUFACTURED PRODUCT, SUBMIT A PRODUCT
 APPROVAL OR NOA- SECTION 905.1.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-10-25 Cont ID  
Sent By ccole Date 2021-10-25 Time 16:33 Rev Time 0.00
Received By ccole Date 2021-10-25 Time 16:33 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved