| Plan Review Stops For Permit 21051556 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-17 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-17 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2021-09-17 15:13:16 | UNIT IS BOUGHT INSIDE BUILDING AND NO ENG REVIEW | | | REQUIRED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2021-08-31 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-08-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-08-31 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-08-31 13:02:52 | PLEASE ADDRESS BUILDING COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-06-02 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-06-02 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-02 12:45:49 | PROVIDE ENGINEERING DRAWING SHOWING PLACEMENT OF GREASE | | | TRAP. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT (561) 494-1098 [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-17 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-16 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-01 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-08-13 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-06-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2021-05-28 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-17 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-17 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2021-09-17 15:12:05 | 09/17/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-08-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-08-26 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-08-26 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2021-08-26 08:25:23 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 21051556 | | | 8/26/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | THE RESUBMITTED PLAN IS INDICATING REPLACEMENT OF AN | | | EXISTING INTERCEPTOR HOWEVER THERE ARE NO RECORDS IN | | | THE WEST PALM BEACH BUILDING DEPARTMENT TO INDICTE A | | | PERMIT WAS EVER OBTAINED TO INSTALL AN INTERCEPTOR AT | | | THE PROJECT ADDRESS- 6108 S. DIXIE HWY UNIT-4. PLEASE | | | CORRECT THE PLAN TO INDICATE A NEW INTERCEPTOR | | | INSTALLATION AND COMPLY WITH THE 1ST REVIEW COMMENTS | | | PRINTED BELOW. PLEASE NOTE THAT MANUFACTURER?S | | | SPECIFICATIONS HAVE BEEN SUBMITTED FOR AN INDOOR | | | INTERCEPTOR HOWEVER SHEET A2 SHOWS THE INTERCEPTOR TO | | | BE LOCATED ON THE EXTERIOR OF THE BUILDING WHICH IS NOT | | | IN COMPLIANCE WITH SECTION 1003.3.4 FBC P. | | | | | | 1ST REVIEW: | | | 1) PROVIDE A DIMENSIONED AND DETAILED PLAN SHOWING THE | | | LOCATION OF THE INTERCEPTOR AND PLUMBING PIPING | | | REQUIREMENTS. SHOW THE GREASE WASTE PIPING RUNS FROM | | | THE FIXTURES TO THE INTERCEPTOR AND FROM THE | | | INTERCEPTOR TO POINT OF CONNECTION TO THE EXISTING | | | BUILDING OR SEWER DRAIN. SHOW LOCATIONS OF ALL REQUIRED | | | CLEANOUTS AND VENTS PER MANUFACTURER?S SPECIFICATIONS- | | | SECTION 1003.3.5 FBC P AND SECTION 107.2.1 WPB. | | | | | | 2) PROVIDE GREASE WASTE CALCULATIONS AND INTERCEPTOR | | | EQUIPMENT SCHEDULE ON THE PLAN IN COMPLIANCE WITH | | | SECTION 1003.3.5 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-16 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-16 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2021-06-16 11:56:20 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21051556 | | | 6/16/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | A COMPREHENSIVE AND THOROUGH REVIEW OF THE INDOOR | | | GREASE INTERCEPTOR CANNOT BE COMPLETED AT THIS TIME DUE | | | TO A LACK OF REQUIRED COMPLIANCE INFORMATION ( SEE | | | COMMENTS 1 & 2 LISTED BELOW), AND ALSO DUE TO THE FACT | | | THAT NO PERMIT FOR THE TENANT SPACE BUILDOUT HAS BEEN | | | ISSUE OR EVEN APPLIED FOR. GREASE INTERCEPTOR PERMITS | | | ARE TYPICALLY ISSUED IN CONJUNCTION WITH PERMITS ISSUED | | | FOR RESTAURANT AND OTHER OCCUPANCIES WHERE GREASE LADEN | | | WASTE IS PRODUCED AS A BY-PRODUCT OF COOKING AND | | | CLEANING OPERATIONS. CURRENTLY THERE IS NO PERMIT | | | APPLICATION AND PLAN SUBMITTED FOR THE PROPOSED | | | OCCUPANCY. | | | | | | 1) PROVIDE A DIMENSIONED AND DETAILED PLAN SHOWING THE | | | LOCATION OF THE INTERCEPTOR AND PLUMBING PIPING | | | REQUIREMENTS. SHOW THE GREASE WASTE PIPING RUNS FROM | | | THE FIXTURES TO THE INTERCEPTOR AND FROM THE | | | INTERCEPTOR TO POINT OF CONNECTION TO THE EXISTING | | | BUILDING OR SEWER DRAIN. SHOW LOCATIONS OF ALL REQUIRED | | | CLEANOUTS AND VENTS PER MANUFACTURER?S SPECIFICATIONS- | | | SECTION 1003.3.5 FBC P AND SECTION 107.2.1 WPB. | | | | | | 2) PROVIDE GREASE WASTE CALCULATIONS AND INTERCEPTOR | | | EQUIPMENT SCHEDULE ON THE PLAN IN COMPLIANCE WITH | | | SECTION 1003.3.5 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-17 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-17 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2021-09-17 07:43:54 | CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTI | | | | | | SIGNATURE REVIEW APPROVED BY PAPER SIGNED/SEALED PLAN | | | SHEETS A-1 & A-2. THESE SHEETS HAVE BEEN ROUTED TO | | | STORAGE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-08-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-08-13 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-13 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-16 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-16 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|