Plan Review Details - Permit 21051470
Plan Review Stops For Permit 21051470
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-07-01 Cont ID  
Sent By rmcdouga Date 2021-07-01 Time 13:52 Rev Time 0.00
Received By rmcdouga Date 2021-07-01 Time 13:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-08 Cont ID  
Sent By ppetty Date 2021-06-08 Time 12:48 Rev Time 0.00
Received By ppetty Date 2021-06-08 Time 12:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-09-27 Cont ID  
Sent By ajones Date 2021-09-27 Time 10:05 Rev Time 0.00
Received By ajones Date 2021-09-14 Time 10:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-08-27 Cont ID  
Sent By rmcdouga Date 2021-08-27 Time 07:34 Rev Time 0.00
Received By rmcdouga Date 2021-08-02 Time 06:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-21 Cont ID  
Sent By jleahy Date 2021-07-21 Time 16:21 Rev Time 0.00
Received By jleahy Date 2021-06-02 Time 09:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-08-12 Cont ID  
Sent By lcrespo Date 2021-08-12 Time 08:41 Rev Time 0.00
Received By lcrespo Date 2021-08-12 Time 08:40 Sent To  
Notes
2021-08-12 08:42:0208/12/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By lcrespo Date 2021-06-03 Time 11:50 Rev Time 0.00
Received By lcrespo Date 2021-06-03 Time 11:50 Sent To  
Notes
2021-06-03 11:52:2605/04/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR
 THE MAXIMUM SYSTEM FLOW. THE TDH CALCULATIONS MUST
 INCLUDE ALL THE SYSTEM COMPONENTS, INCLUDING SUCTION
 AND RETURN PIPING, FITTINGS, VALVES, HEATER, AND
 FILTER. ALL SYSTEM COMPONENTS EXCEPT THE PUMP.
  
 2. PLEASE THE POOL PUMP CURVE. IDENTIFY ON THE PUMP
 CURVE WHICH CURVE KEY IS SPECIFIC TO THE PUMP BEING
 INSTALLED ON THIS POOL. THIS IS NEEDED TO CONFIRM THE
 MAXIMUM SYSTEM FLOW FROM THE TDH CALCULATIONS PER THE
 ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, 4.4.9.1. INDICATE
 ON THE PUMP CURVE WHICH CURVE KEY IS FOR THE PUMP BEING
 INSTALLED ON THIS SYSTEM PER THE WPB AMEND. TO FBC SEC.
 107.2.1.
  
 3. PLEASE SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR
 THE FILTER, AND PUMP PER THE WPB AMENDMENTS TO FBC SEC.
 107.2.1.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-08-27 Cont ID  
Sent By rmcdouga Date 2021-08-27 Time 07:34 Rev Time 0.00
Received By rmcdouga Date 2021-08-27 Time 07:34 Sent To  
Notes
2021-08-27 07:49:56ENGINEER'S ORIGINAL SIGNATURE AND SEAL ON DRAWINGS WERE
 SENT TO STORAGE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-01 Cont ID  
Sent By rmcdouga Date 2021-07-01 Time 13:52 Rev Time 0.00
Received By rmcdouga Date 2021-07-01 Time 13:52 Sent To  
Notes
2021-07-01 13:59:24I WAS NOT ABLE TO VERIFY THE ENGINEER'S DIGITAL
 SIGNATURE. ELECTRONICALLY SUBMITTED DRAWINGS ARE
 REQUIRED TO HAVE THE ARCHITECT OR ENGINEER'S DIGITAL
 SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT
 THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. AFTER
 THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT
 THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING
 DEPARTMENT TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S
 ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO
 BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF
 THE SIGNATURE ARE ACCEPTABLE. FS 481 & 61G1 OR FS 471 &
 61G15
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2021-09-27 Cont ID  
Sent By ajones Date 2021-09-27 Time 10:05 Rev Time 0.00
Received By ajones Date 2021-09-27 Time 10:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2021-08-25 Cont ID  
Sent By kalexand Date 2021-08-25 Time 18:33 Rev Time 0.00
Received By kalexand Date 2021-08-25 Time 18:33 Sent To I
Notes
2021-08-25 19:15:05ZONING PLAN REVIEW
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. UPON FURTHER REVIEW, SURVEY PROVIDED DOESN'T MATCH
 THE STRUCTURE CURRENTLY ON THE SITE, THEREFORE A
 CURRENT PROPERTY SURVEY MUST BE PROVIDED SHOWING ALL
 CURRENT STRUCTURES AND SETBACKS.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-07-20 Cont ID  
Sent By kalexand Date 2021-07-20 Time 15:33 Rev Time 0.00
Received By kalexand Date 2021-07-20 Time 15:33 Sent To I
Notes
2021-07-20 15:34:42ZONING PLAN REVIEW
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLEASE ILLUSTRATE THE FOLLOWING ON THE SURVEY:
 - LOCATION OF PROPOSED POOL AND EQUIPMENT
 - DISTANCE FROM POOL AND EQUIPMENT TO ADJACENT PROPERTY
 LINES
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved