| Plan Review Stops For Permit 21051365 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-03-11 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-03-11 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-01 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-01 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2022-02-01 10:25:09 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE INDICATE THE ON CENTER SPACING OF | | | THE 2"X 6" RAFTERS. THIS MUST MEET THE REQUIREMENTS OF | | | THE FBC R 802.5. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-12-15 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-15 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2021-12-15 10:33:47 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW APPROVED | | | | | | NOTE: THE ROOFING REVIEW STOP MUST BE APPROVED PRIOR TO | | | PERMIT APPLICATION APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-10-12 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-10-12 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-10-12 13:48:55 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE MORE DETAILED INFORMATION | | | INCLUDING: | | | | | | 1) ELEVATION VIEWS FROM EACH SIDE. | | | 2) DETAILS OF EACH CONNECTION INCLUDING MATERIALS AND | | | BRACING (SIGNED/SEALED) BY DESIGN PROFESSIONAL. | | | 3) WINDLOAD PRESSURES AND WIND SPEEDS THAT ARE APPROVED | | | (SIGNED/SEALED) BY DESIGN PROFESSIONAL. | | | 5) ROOF FRAMING/ROOF SYSTEM IS INCOMPLETE, MORE DETAILS | | | ARE REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-07-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-07-16 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-07-16 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2021-07-16 07:38:57 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE MORE DETAILED INFORMATION | | | INCLUDING: | | | | | | 1) ELEVATION VIEWS FROM EACH SIDE. | | | 2) DETAILS OF EACH CONNECTION INCLUDING MATERIALS AND | | | BRACING (SIGNED/SEALED) BY DESIGN PROFESSIONAL. | | | 3) WINDLOAD PRESSURES AND WIND SPEEDS THAT ARE APPROVED | | | (SIGNED/SEALED) BY DESIGN PROFESSIONAL. | | | 4) SITE?PLAN SHOWING THE SETBACKS (DISTANCES) FROM | | | ADJACENT STRUCTURES AND PROPERTY LINES. | | | 5) ROOF FRAMING/ROOF SYSTEM IS INCOMPLETE, MORE DETAILS | | | ARE REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-02 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-02 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2021-06-02 09:48:34 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE MORE DETAILED INFORMATION | | | INCLUDING: | | | | | | 1) ELEVATION VIEWS FROM EACH SIDE. | | | 2) DETAILS OF EACH CONNECTION INCLUDING MATERIALS AND | | | BRACING (SIGNED/SEALED) BY DESIGN PROFESSIONAL. | | | 3) WINDLOAD PRESSURES AND WIND SPEEDS THAT ARE APPROVED | | | (SIGNED/SEALED) BY DESIGN PROFESSIONAL. | | | 4) SITE-PLAN SHOWING THE SETBACKS (DISTANCES) FROM | | | ADJACENT STRUCTURES AND PROPERTY LINES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-03-11 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-18 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-01 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-24 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-12-15 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-02 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-10-12 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-20 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-08-19 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-12 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-06-18 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-25 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-01 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-01 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-12-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-15 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2021-12-15 09:59:16 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW DENIED: | | | | | | FBC B 107.2.1: | | | | | | PLEASE PROVIDE THE PRODUCT APPROVALS REQUIRED FOR ALL | | | ROOFING MATERIALS TO BE USED. | | | IF THE PRODUCT APPROVALS DO NOT INDICATE OR DO NOT MEET | | | THE WINDLOAD PRESSURE REQUIREMENTS FOR THE ROOFING | | | SYSTEM TO BE USED, THE ENGINEER'S SIGNED/SEALED | | | FASTENER SPACING CALCULATIONS WILL BE REQUIRED. | | | | | | A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO STARTING ANY | | | ROOF WORK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-18 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-18 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2022-02-18 13:08:11 | HARD COPY DWGS 1,2,3 AND 4 W/ ENGINEER'S EMBOSSED SEAL | | | & ORIGINAL SIGNATURE.JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-12-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-12-02 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-12-02 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2021-12-02 16:57:48 | SIGNED AND SEALED PAPER PLANS AND CALCULATIONS SENT TO | | | STORAGE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-10-12 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-10-12 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-10-12 13:52:44 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | SIGNATURE REVIEW DENIED: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD/EMAIL A DIGITALLY SIGNED (THIRD PARTY VERIFIED) | | | PLAN OR YOU CAN MAIL/HAND DELIVER AN ORIGINAL | | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | 401 CLEMATIS STREET | | | P.O. BOX 3147 | | | WEST PALM BEACH, FL 33402 | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES/BUILDING DEPT. | | | 561 805 6673 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-07-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-07-16 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-07-16 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2021-07-16 07:40:24 | SIGNATURE REVIEW DENIED: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD/EMAIL A DIGITALLY SIGNED (THIRD PARTY VERIFIED) | | | PLAN OR YOU CAN MAIL/HAND DELIVER AN ORIGINAL | | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | 401 CLEMATIS STREET | | | P.O. BOX 3147 | | | WEST PALM BEACH, FL 33402 | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES/BUILDING DEPT. | | | 561 805 6673 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-02 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-02 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2021-06-02 09:50:19 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | SIGNATURE REVIEW DENIED: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN OR YOU CAN MAIL AN ORIGINAL | | | SIGNED/SEALED PAPER ORIGINAL TO: | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | 401 CLEMATIS STREET | | | P.O. BOX 3147 | | | WEST PALM BEACH, FL 33402 | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES/BUILDING DEPT. | | | 561 805 6673 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-09-27 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-09-27 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-08-17 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-08-17 |
Time |
18:02 |
Sent To |
I |
|
| Notes |
| 2021-08-17 18:10:51 | PROVIDE CERTIFIED AND SEALED PROPOERTY SURVEY COMPLETED | | | BY A LICENSED SERVEYOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-06-18 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-06-18 |
Time |
12:51 |
Sent To |
I |
|
| Notes |
| 2021-06-18 12:52:12 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PROVIDE A CURRENT SURVEY, WHICH INCLUDES THE | | | PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. PLEASE | | | ILLUSTRATE THE FOLLOWING ON THE SURVEY: | | | - LOCATION OF THE PROPOSED ENCLOSURE. | | | - SETBACK DIMENSIONS FROM ANY EXTERIOR IMPROVEMENTS TO | | | ALL ADJACENT PROPERTY LINES. | | | | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|